Wearable Inertial Sensor Approach for Postural Adjustment Assessments during Predictable Perturbations in Sport
Authors:
- Manuela Brito DuarteMDManuela Brito Duarte
- Anderson Antunes da Costa MoraesAMAnderson Antunes da Costa Moraes
- Eduardo Veloso FerreiraEFEduardo Veloso Ferreira
- Gizele Cristina da Silva AlmeidaGAGizele Cristina da Silva Almeida
- André dos Santos CabralACAndré dos Santos Cabral
- Anselmo de Athayde Costa e SilvaAnselmo de Athayde Costa e Silva
- Daniela Rosa GarcezDGDaniela Rosa Garcez
- Givago da Silva SouzaGivago da Silva Souza
- Bianca CallegariBCBianca Callegari
Open Access
Abstract
Introduction: Evidence supports the importance of efficient postural control to improve performance in sports. This involves the use of strategies such as anticipatory posture adjustments and compensatory adjustments. Technology makes analysis and assessments in sports cheaper, while being valid and reliable compared to the gold-standard assessment equipment. Objectives: This article aimed to test the validity and reliability of signals extracted from the sensor’s accelerometer (Metamotion C), by comparing it to the data obtained from the gold-standard equipment (a three-dimensional video-motion-capture system). Design: Observational, cross-sectional study. Methods: We exposed 20 healthy young standing people to the pendulum impact paradigm, which consisted of predictable anteroposterior disturbances applied at the shoulder level. In order to measure this, we observed the acceleration of the center of mass in the anticipatory and compensatory phase of the disturbance and compared the signals of the two devices (Metamotion C and a motion-capture system). Results: The validation results showed the significant linear correlation of all variables with a moderate to large correlation of r ≥ 0.5 between the devices. In contrast, the reliability results between sessions obtained by filming were all significant and above 0.75, indicating excellent reliability. The APAonset variable had a reasonable to high intra-class correlation in the anticipatory phase. In the compensatory phase, the CPAtime variable showed an excellent correlation. Conclusions: Metamotion C proved reasonably valid and highly reliable in measuring the center of mass acceleration compared to the camera system in both the anticipatory and compensatory phases.Keywords
Funding Information
- Amazon Paraense Foundation of Studies (2019/589349, 431748/2016-0, 310845/2018-1)
- PROPESP/Federal University of Para (PAPQ) (2019/589349, 431748/2016-0, 310845/2018-1)
- CNPq (2019/589349, 431748/2016-0, 310845/2018-1)
This publication has 22 references indexed in Scilit:
- Inconsistent anticipatory postural adjustments (APAs) in rugby players: a source of injuries?BMJ Open Sport & Exercise Medicine, 2018
- Definition of the proper placement point for balance assessment with accelerometers in older womenRevista Andaluza de Medicina del Deporte, 2016
- Comparison of Non-Invasive Individual Monitoring of the Training and Health of Athletes with Commercially Available Wearable TechnologiesFrontiers in Physiology, 2016
- Wearable Performance Devices in Sports MedicineSports Health: A Multidisciplinary Approach, 2015
- Whole body mechanics differ among running and cutting maneuvers in skilled athletesGait & Posture, 2015
- The effect of aging on anticipatory postural controlExperimental Brain Research, 2014
- Reliability, Standard Error, and Minimum Detectable Change of Clinical Pressure Pain Threshold Testing in People With and Without Acute Neck PainJournal of Orthopaedic & Sports Physical Therapy, 2011
- Effects of lateral perturbations and changing stance conditions on anticipatory postural adjustmentJournal of Electromyography and Kinesiology, 2009
- Physical Demands of Different Positions in FA Premier League Soccer.2007
- Assessment of spatio-temporal gait parameters from trunk accelerations during human walkingGait & Posture, 2003