Anderson Antunes da Costa Moraes
Anderson Antunes da Costa Moraes has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- André dos Santos Cabral
Centro de Ciências Biológicas e da Saúde, Universidade do Estado do Pará, Tv. Perebebuí, 2623-Marco, Belém 66087-662, PA, Brazil
3 shared publications - Anselmo de Athayde Costa e Silva
Universidade federal do Pará
3 shared publications - Bianca Callegari
Instituto de Ciências da Saúde, Universidade Federal do Pará, Belém, Brazil
3 shared publications - Eduardo Veloso Ferreira
Laboratório de Estudos da Motricidade Humana, Av. Generalíssimo Deodoro 01, Belém 66073-00, PA, Brazil
3 shared publications - Givago Silva Souza
Núcleo de Medicina Tropical, Universidade Federal do Pará, Belém, Brazil
3 shared publications - Gizele Cristina da Silva Almeida
Laboratório de Estudos da Motricidade Humana, Av. Generalíssimo Deodoro 01, Belém 66073-00, PA, Brazil
3 shared publications
Latest Publications
- Open Access
Wearable Inertial Sensor Approach for Postural Adjustment Assessments during Predictable Perturbations in Sport
Introduction: Evidence supports the importance of efficient postural control to improve performance in sports. This involves the use of strategies such as anticipatory posture adjustments and compensatory adjustments. Technology makes analysis and assessments in sports cheaper, while being valid and reliable compared to the gold-standard assessment equipment. Objectives: This article aimed to test the validity and reliability of signals extracted from the sensor’s accelerometer (Metamotion C), by comparing it to the data obtained from the gold-standard equipment (a three-dimensional video-motion-capture system). Design: Observational, cross-sectional study. Methods: We exposed 20 healthy young standing people to the pendulum impact paradigm, which consisted of predictable anteroposterior disturbances applied at the shoulder level. In order to measure this, we observed the acceleration of the center of mass in the anticipatory and compensatory phase of the disturbance and compared the signals of the two devices (Metamotion C and a motion-capture system). Results: The validation results showed the significant linear correlation of all variables with a moderate to large correlation of r ≥ 0.5 between the devices. In contrast, the reliability results between sessions obtained by filming were all significant and above 0.75, indicating excellent reliability. The APAonset variable had a reasonable to high intra-class correlation in the anticipatory phase. In the compensatory phase, the CPAtime variable showed an excellent correlation. Conclusions: Metamotion C proved reasonably valid and highly reliable in measuring the center of mass acceleration compared to the camera system in both the anticipatory and compensatory phases.
Open AccessWearable Inertial Sensor Approach for Postural Adjustment Assessments during Predictable Perturbations in Sport
Introduction: Evidence supports the importance of efficient postural control to improve performance in sports. This involves the use of strategies such as anticipatory posture adjustments and compensatory adjustments. Technology makes analysis and assessments in sports cheaper, while being valid and reliable compared to the gold-standard assessment equipment. Objectives: This article aimed to test the validity and reliability of signals extracted from the sensor’s accelerometer (Metamotion C), by comparing it to the data obtained from the gold-standard equipment (a three-dimensional video-motion-capture system). Design: Observational, cross-sectional study. Methods: We exposed 20 healthy young standing people to the pendulum impact paradigm, which consisted of predictable anteroposterior disturbances applied at the shoulder level. In order to measure this, we observed the acceleration of the center of mass in the anticipatory and compensatory phase of the disturbance and compared the signals of the two devices (Metamotion C and a motion-capture system). Results: The validation results showed the significant linear correlation of all variables with a moderate to large correlation of r ≥ 0.5 between the devices. In contrast, the reliability results between sessions obtained by filming were all significant and above 0.75, indicating excellent reliability. The APAonset variable had a reasonable to high intra-class correlation in the anticipatory phase. In the compensatory phase, the CPAtime variable showed an excellent correlation. Conclusions: Metamotion C proved reasonably valid and highly reliable in measuring the center of mass acceleration compared to the camera system in both the anticipatory and compensatory phases.
- Open Access
Validity and Reliability of Smartphone App for Evaluating Postural Adjustments during Step Initiation
The evaluation of anticipatory postural adjustments (APAs) requires high-cost and complex handling systems, only available at research laboratories. New alternative methods are being developed in this field, on the other hand, to solve this issue and allow applicability in clinic, sport and hospital environments. The objective of this study was to validate an app for mobile devices to measure the APAs during gait initiation by comparing the signals obtained from cell phones using the Momentum app with measurements made by a kinematic system. The center-of-mass accelerations of a total of 20 healthy subjects were measured by the above app, which read the inertial sensors of the smartphones, and by kinematics, with a reflective marker positioned on their lumbar spine. The subjects took a step forward after hearing a command from an experimenter. The variables of the anticipatory phase, prior to the heel-off and the step phase, were measured. In the anticipatory phase, the linear correlation of all variables measured by the two measurement techniques was significant and indicated a high correlation between the devices (APAonset: r = 0.95, p < 0.0001; APAamp: r = 0.71, p = 0.003, and PEAKtime: r = 0.95, p < 0.0001). The linear correlation between the two measurement techniques for the step phase variables measured by ques was also significant (STEPinterval: r = 0.56, p = 0.008; STEPpeak1: r = 0.79, p < 0.0001; and STEPpeak2: r = 0.64, p < 0.0001). The Bland–Altman graphs indicated agreement between instruments with similar behavior as well as subjects within confidence limits and low dispersion. Thus, using the Momentum cell phone application is valid for the assessment of APAs during gait initiation compared to the gold standard instrument (kinematics), proving to be a useful, less complex, and less costly alternative for the assessment of healthy individuals.
Open AccessValidity and Reliability of Smartphone App for Evaluating Postural Adjustments during Step Initiation
The evaluation of anticipatory postural adjustments (APAs) requires high-cost and complex handling systems, only available at research laboratories. New alternative methods are being developed in this field, on the other hand, to solve this issue and allow applicability in clinic, sport and hospital environments. The objective of this study was to validate an app for mobile devices to measure the APAs during gait initiation by comparing the signals obtained from cell phones using the Momentum app with measurements made by a kinematic system. The center-of-mass accelerations of a total of 20 healthy subjects were measured by the above app, which read the inertial sensors of the smartphones, and by kinematics, with a reflective marker positioned on their lumbar spine. The subjects took a step forward after hearing a command from an experimenter. The variables of the anticipatory phase, prior to the heel-off and the step phase, were measured. In the anticipatory phase, the linear correlation of all variables measured by the two measurement techniques was significant and indicated a high correlation between the devices (APAonset: r = 0.95, p < 0.0001; APAamp: r = 0.71, p = 0.003, and PEAKtime: r = 0.95, p < 0.0001). The linear correlation between the two measurement techniques for the step phase variables measured by ques was also significant (STEPinterval: r = 0.56, p = 0.008; STEPpeak1: r = 0.79, p < 0.0001; and STEPpeak2: r = 0.64, p < 0.0001). The Bland–Altman graphs indicated agreement between instruments with similar behavior as well as subjects within confidence limits and low dispersion. Thus, using the Momentum cell phone application is valid for the assessment of APAs during gait initiation compared to the gold standard instrument (kinematics), proving to be a useful, less complex, and less costly alternative for the assessment of healthy individuals.
- Open Access
- 20 December 2018
- Published by NEPAS in ABCS Health Sciences
- Vol. 43 (3)
Estresse oxidativo na interrupção da ventilação mecânica em pacientes vítimas de traumatismo cranioencefálico: um estudo randomizado e cego
Introdução: Os efeitos tóxicos do oxigênio não estão bem estabelecidos em seres humanos. Objetivo: Analisar os níveis de estresse oxidativo (EOx) na interrupção da ventilação mecânica (VM) em pacientes vítimas de TCE. Métodos: Estudo prospectivo, longitudinal, analítico, randomizado e cego. Participaram 12 pacientes: PSV (n=6) e grupo Tubo-T (n=6). A interrupção da VM deu-se em: PSV- (Δ 7 cmH2O) e PEEP (5 cmH2O) durante 30 minutos; Tubo-T - o paciente foi conectado ao tubo T com FiO2 a 0,4 durante 30 minutos. Realizou-se avaliação morfológica do EOx no plasma sanguíneo pelo Dry layer oxidative test. A coleta foi realizada: com 24h de VM, antes do teste, em 15’ de teste e após o teste PSV ou Tubo-T. Para análise da normalidade utilizou-se o teste de Shapiro-Wilk para análise intragrupo e intergrupos, o teste ANOVA seguido de Tukey; para correlação-Correlação de Spearman (p valor 5%). Resultados: Não houve aumento estatisticamente significativo na descontinuidade da matriz extracelular nos grupos (p>0,05). Os níveis de EOx encontraram-se elevados (grau III–moderado) nas primeiras avaliações. Não foi encontrada correlação significativa entre os parâmetros de VM com o EOx. O grupo PSV permaneceu em média 12.33 dias sob VM, tendo EOx de 29.02 (grau III/ moderado) – r=0.8, p=0.01; o grupo Tubo T em média 12.83±2.2 dias, tendo EOx de 31.03±5.41 (grau IV/grave)- r=0.9, p=0.07. Conclusão: Não houve diferença no comportamento do EOx entre os métodos de interrupção da VM. No entanto, o EOx aumentou com o tempo de VM.
- 20 December 2018
- Published by NEPAS in ABCS Health Sciences
- Vol. 43 (3)
Open AccessEstresse oxidativo na interrupção da ventilação mecânica em pacientes vítimas de traumatismo cranioencefálico: um estudo randomizado e cego
Introdução: Os efeitos tóxicos do oxigênio não estão bem estabelecidos em seres humanos. Objetivo: Analisar os níveis de estresse oxidativo (EOx) na interrupção da ventilação mecânica (VM) em pacientes vítimas de TCE. Métodos: Estudo prospectivo, longitudinal, analítico, randomizado e cego. Participaram 12 pacientes: PSV (n=6) e grupo Tubo-T (n=6). A interrupção da VM deu-se em: PSV- (Δ 7 cmH2O) e PEEP (5 cmH2O) durante 30 minutos; Tubo-T - o paciente foi conectado ao tubo T com FiO2 a 0,4 durante 30 minutos. Realizou-se avaliação morfológica do EOx no plasma sanguíneo pelo Dry layer oxidative test. A coleta foi realizada: com 24h de VM, antes do teste, em 15’ de teste e após o teste PSV ou Tubo-T. Para análise da normalidade utilizou-se o teste de Shapiro-Wilk para análise intragrupo e intergrupos, o teste ANOVA seguido de Tukey; para correlação-Correlação de Spearman (p valor 5%). Resultados: Não houve aumento estatisticamente significativo na descontinuidade da matriz extracelular nos grupos (p>0,05). Os níveis de EOx encontraram-se elevados (grau III–moderado) nas primeiras avaliações. Não foi encontrada correlação significativa entre os parâmetros de VM com o EOx. O grupo PSV permaneceu em média 12.33 dias sob VM, tendo EOx de 29.02 (grau III/ moderado) – r=0.8, p=0.01; o grupo Tubo T em média 12.83±2.2 dias, tendo EOx de 31.03±5.41 (grau IV/grave)- r=0.9, p=0.07. Conclusão: Não houve diferença no comportamento do EOx entre os métodos de interrupção da VM. No entanto, o EOx aumentou com o tempo de VM.