Unifying the Estimation of Blood Volume Decompensation Status in a Porcine Model of Relative and Absolute Hypovolemia Via Wearable Sensing
- 24 March 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (9) , 3351-3360
Abstract
Hypovolemia remains the leading cause of preventable death in trauma cases. Recent research has demonstrated that using noninvasive continuous waveforms rather than traditional vital signs improves accuracy in early detection of hypovolemia to assist in triage and resuscitation. This work evaluates random forest models trained on different subsets of data from a pig model (n = 6) of absolute (bleeding) and relative (nitroglycerin-induced vasodilation) progressive hypovolemia (to 20% decrease in mean arterial pressure) and resuscitation. Features for the models were derived from a multi-modal set of wearable sensors, comprised of the electrocardiogram (ECG), seismocardiogram (SCG) and reflective photoplethysmogram (RPPG) and were normalized to each subject.s baseline. The median RMSE between predicted and actual percent progression towards cardiovascular decompensation for the best model was 30.5% during the relative period, 16.8% during absolute and 22.1% during resuscitation. The least squares best fit line over the mean aggregated predictions had a slope of 0.65 and intercept of 12.3, with an R 2 value of 0.93. When transitioned to a binary classification problem to identify decompensation, this model achieved an AUROC of 0.80. This study: a) developed a global model incorporating ECG, SCG and RPPG features for estimating individual-specific decompensation from progressive relative and absolute hypovolemia and resuscitation; b) demonstrated SCG as the most important modality to predict decompensation; c) demonstrated efficacy of random forest models trained on different data subsets; and d) demonstrated adding training data from two discrete forms of hypovolemia increases prediction accuracy for the other form of hypovolemia and resuscitation.Keywords
Funding Information
- Office of Naval Research (N00014-21-1-203, N000141812579)
This publication has 35 references indexed in Scilit:
- A Systematic Review of the Relationship between Blood Loss and Clinical SignsPLOS ONE, 2013
- Died of Wounds on the Battlefield: Causation and Implications for Improving Combat Casualty CareJournal of Trauma: Injury, Infection & Critical Care, 2011
- Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based methodEuropean Journal of Applied Physiology, 2011
- Towards Using Photo-Plethysmogram Amplitude to Measure Blood Pressure During SleepAnnals of Biomedical Engineering, 2010
- Ability of pleth variability index to detect hemodynamic changes induced by passive leg raising in spontaneously breathing volunteersCritical Care, 2008
- Prediction of Mortality and of the Need for Massive Transfusion in Casualties Arriving at Combat Support Hospitals in IraqJournal of Trauma: Injury, Infection & Critical Care, 2008
- Photoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart RateAnesthesia & Analgesia, 2007
- Heart rate variability: a reviewMedical & Biological Engineering & Computing, 2006
- A critical review of the systolic time intervals.Circulation, 1977
- Systolic Time Intervals as Measures of the Contractile State of the Left Ventricular Myocardium in ManCirculation, 1972