SASungtae An

Sungtae An

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sungtae An has a total of 120 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Modeling Latent Dynamics of the Autonomic Nervous System in Response to Trauma Recall and Non-Invasive Vagus Nerve Stimulation

    by Asim H. Gazi, Sungtae An, Jesus Antonio Sanchez-Perez, Michael Chan, Mohammad Nikbakht, David J. Lin, Shlok Natarajan, Kyle A. Johnsen, J. Douglas Bremner, Jin-Oh Hahn, et al.

    Objective: To develop a person-specific dynamic modeling approach to quantify the time course of multiple peripheral markers of the autonomic nervous system (ANS) in response to acute stressors and potential stress-reducing interventions. Methods: We curated data (N = 50 participants) from a double-blind, randomized, sham-controlled trial of non-invasive vagus nerve stimulation (nVNS) for posttraumatic stress disorder (PTSD). For each participant, a multi-input, multi-output, linear state space model (SSM) was trained on $\sim$3500 s of cardiovascular and respiratory marker time series data and tested for predictive validity on $\sim$2000 s of held-out data. The inputs to each SSM indicated the presence or absence of potential stressors (e.g., traumatic memories) and interventions (e.g., nVNS or sham stimulation). We analyzed the SSMs' step responses to each input and compared the responses to real data. We then simulated the effects of just-in-time nVNS delivered during a traumatic memory. Results: The SSMs outperformed baseline forecasting methods on held-out data (P $< $ .05). Responses to nVNS were in the opposite direction of responses to traumatic memories, with neutral conditions (included for comparison) remaining in between. For participants with PTSD, just-in-time nVNS attenuated–and briefly reversed–the response to traumatic memories along the principal axis of variance, which explained $\sim$50% or more variance and mirrored expected ANS changes. Just-in-time sham stimulation produced no attenuation. Conclusion: Our methods capture latent ANS dynamics during increasing and decreasing stress levels associated with traumatic memories and nVNS, respectively. Significance: Traumatic memories can cause pathological stress responses during daily life that just-in-time non-invasive neuromodulation may potentially help mitigate.


  • Predicting Soldier Performance on Structured Military Training Marches With Wearable Accelerometer and Physiological Data

    by David J. Lin, Aprameya Satish, Kristine L. S. Richardson, Sungtae An, Cem O. Yaldiz, Mark Buller, Kyla Driver, Emma Atkinson, Timothy Mesite, Christopher King, et al.

    Performance metrics are extremely important for military instructors and leadership to gauge soldier fitness and readiness and adjust training regimens accordingly. One important performance indicator during military training events is the time taken for a soldier to complete a structured march, hereon referred to as Time-to-Completion (TTC). During these marches, wearable physiological sensors can be used to infer a soldier’s physiological state and exertion rate, which in turn can be used for predicting TTC. In this work, we present a model that uses signals from a multi-modal wearable sensor to predict TTC for soldiers undergoing a 12-mile structured ruck march. Predictions are made at discrete time points (checkpoints) throughout the march using features from skin temperature, heart rate, estimated core temperature, and triaxial accelerometry. To utilize the structured nature of these marches, separate models are trained at each checkpoint using features from both the current and past checkpoints. By 120 minutes (2/3 of the expected 180-minute completion time), we achieved a TTC RMSE of 7.12 mins and a MAE of 5.21 min using this model. Integral to TTC estimation accuracy were gait related features such as the standard deviation of vertical acceleration. Features such as heart rate slope and performance metrics from prior exercises minimally improved accuracy. The deployment of this model will enable continuous monitoring of performance metrics for online TTC estimation.


  • Early Prediction of Impending Exertional Heat Stroke With Wearable Multimodal Sensing and Anomaly Detection

    by Cem O. Yaldiz, Mark J. Buller, Kristine L. Richardson, Sungtae An, David J. Lin, Aprameya Satish, Kyla Driver, Emma Atkinson, Timothy Mesite, Christopher King, et al.

    We employed wearable multimodal sensing (heart rate and triaxial accelerometry) with machine learning to enable early prediction of impending exertional heat stroke (EHS). US Army Rangers and Combat Engineers (N = 2,102) were instrumented while participating in rigorous 7-mile and 12-mile loaded rucksack timed marches. There were three EHS cases, and data from 478 Rangers were analyzed for model building and controls. The data-driven machine learning approach incorporated estimates of physiological strain (heart rate) and physical stress (estimated metabolic rate) trajectories, followed by reconstruction to obtain compressed representations which then fed into anomaly detection for EHS prediction. Impending EHS was predicted from 33 to 69 min before collapse. These findings demonstrate that low dimensional physiological stress to strain patterns with machine learning anomaly detection enables early prediction of impending EHS which will allow interventions that minimize or avoid pathophysiological sequelae. We describe how our approach can be expanded to other physical activities and enhanced with novel sensors.


  • Interrater Reliability of Expert Electroencephalographers Identifying Seizures and Rhythmic and Periodic Patterns in EEGs

    by Jin Jing, Wendong Ge, Aaron F. Struck, Marta Bento Fernandes, Shenda Hong, Sungtae An, Safoora Fatima, Aline Herlopian, Ioannis Karakis, Jonathan J. Halford, et al.

    Background and Objectives: The validity of brain monitoring using electroencephalography (EEG), particularly to guide care in patients with acute or critical illness, requires that experts can reliably identify seizures and other potentially harmful rhythmic and periodic brain activity, collectively referred to as “ictal-interictal-injury continuum" (IIIC). Prior inter-rater reliability (IRR) studies are limited by small samples and selection bias. This study was conducted to assess the reliability of experts in identifying IIIC. Methods: This prospective analysis included 30 experts with subspecialty clinical neurophysiology training from 18 institutions. Experts independently scored varying numbers of ten-second EEG segments as: “Seizure (SZ)”, “Lateralized Periodic Discharges (LPD)”, “Generalized Periodic Discharges (GPD)”, “Lateralized Rhythmic Delta Activity (LRDA)”, “Generalized Rhythmic Delta Activity (GRDA)”, or “Other”. EEGs were performed for clinical indications at Massachusetts General Hospital between 2006 to 2020. Primary outcome measures were pairwise IRR (average percent agreement (PA) between pairs of experts) and majority IRR (average PA with group consensus) for each class; and beyond chance agreement (κ). Secondary outcomes were calibration of expert scoring to group consensus, and latent trait analysis to investigate contributions of bias and noise to scoring variability. Results: Among 2,711 EEGs, 49% were from females, and median (IQR) age was 55 (41). In total experts scored 50,697 EEG segments; the median [range] number scored by each expert was 6,287.5 [1,002, 45,267]. Overall pairwise IRR was moderate (PA 52%, κ 42%), and majority IRR was substantial (PA 65%, κ 61%). Noise-bias analysis demonstrated that a single underlying receiver operating curve can account for most variation in experts9 false positive vs true positive characteristics (median [range] of variance explained (R2): 95 [93, 98]%), and for most variation in experts’ precision vs sensitivity characteristics (R2: 75 [59, 89]%). Thus, variation between experts is mostly attributable not to differences in expertise, but rather to variation in decision thresholds. Discussion: Our results provide precise estimates of expert reliability from a large and diverse sample, and a parsimonious theory to explain the origin of disagreements between experts. The results also establish a standard for how well an automated IIIC classifier must perform to match experts. Classification of Evidence: This study provides Class II evidence that independent expert review reliably identifies ictal-interictal injury continuum patterns on EEG compared to expert consensus.


  • Open Access

    Wearable Seismocardiography‐Based Assessment of Stroke Volume in Congenital Heart Disease

    by Venu G. Ganti, Asim H. Gazi, Sungtae An, Adith V. Srivatsa, Brandi N. Nevius, Christopher J. Nichols, Andrew M. Carek, Munes Fares, Mubeena Abdulkarim, Tarique Hussain, et al.

    Background: Patients with congenital heart disease (CHD) are at risk for the development of low cardiac output and other physiologic derangements, which could be detected early through continuous stroke volume (SV) measurement. Unfortunately, existing SV measurement methods are limited in the clinic because of their invasiveness (eg, thermodilution), location (eg, cardiac magnetic resonance imaging), or unreliability (eg, bioimpedance). Multimodal wearable sensing, leveraging the seismocardiogram, a sternal vibration signal associated with cardiomechanical activity, offers a means to monitoring SV conveniently, affordably, and continuously. However, it has not been evaluated in a population with significant anatomical and physiological differences (ie, children with CHD) or compared against a true gold standard (ie, cardiac magnetic resonance). Here, we present the feasibility of wearable estimation of SV in a diverse CHD population (N=45 patients). Methods and Results: We used our chest‐worn wearable biosensor to measure baseline ECG and seismocardiogram signals from patients with CHD before and after their routine cardiovascular magnetic resonance imaging, and derived features from the measured signals, predominantly systolic time intervals, to estimate SV using ridge regression. Wearable signal features achieved acceptable SV estimation (28% error with respect to cardiovascular magnetic resonance imaging) in a held‐out test set, per cardiac output measurement guidelines, with a root‐mean‐square error of 11.48 mL and R 2 of 0.76. Additionally, we observed that using a combination of electrical and cardiomechanical features surpassed the performance of either modality alone. Conclusions: A convenient wearable biosensor that estimates SV enables remote monitoring of cardiac function and may potentially help identify decompensation in patients with CHD.


  • DynaLAP: Human Activity Recognition in Fixed Protocols via Semi-Supervised Variational Recurrent Neural Networks With Dynamic Priors

    by Sungtae An, Asim H. Gazi, Omer T. Inan

    Learning the route and order of tasks can be critical to human activity recognition (HAR) for fixed protocols of movement. In this article, we propose a novel framework, DynaLAP, a semi-supervised variational recurrent neural network (VRNN) with a dynamic prior distribution, to perform activity recognition in fixed protocols. DynaLAP takes single tri-axial accelerometry data as input and causally classifies the activity of 10–30-s windows at a time. DynaLAP learns not only a window-specific short-term state, but also a long-term dynamic state iteratively updated throughout the protocol’s measurements. Additionally, instead of using a stationary prior distribution of activity classes, DynaLAP learns a dynamic prior that updates for each window. DynaLAP thereby learns protocol-specific dynamics when trained on data from subjects abiding by a fixed protocol. Two datasets from previously published literature were used to evaluate DynaLAP: the fully labeled MotionSense dataset of 24 subjects and a weakly labeled dataset of 17 subjects collected at the Georgia Institute of Technology. For each dataset, we varied the number of training labels used from a single subject’s data to the entire dataset. DynaLAP outperformed previous supervised and semi-supervised HAR approaches by 6–42 percentage points, with F1 scores that remained above 80%. These results suggest that DynaLAP can achieve state-of-the-art HAR performance in fixed protocols by learning protocol-specific dynamics, especially in weakly and scarcely labeled settings. DynaLAP could ultimately reduce the necessity for labor-intensive annotation efforts in HAR applications involving routine activities (e.g., military training).


  • Quantifying Asymmetry Between Medial and Lateral Compartment Knee Loading Forces Using Acoustic Emissions

    by Hyeon Ki Jeong, Sungtae An, Kinsey Herrin, Keaton Scherpereel, Aaron Young, Omer T. Inan

    Objective : Osteoarthritis is the most common type of knee arthritis that can be affected by excessive and compressive loads and can affect one or more compartments of the knee: medial, lateral, and patellofemoral. The medial compartment tends to be the most vulnerable to injuries and research suggests that a better understanding of the medial to lateral load distribution conditions could provide insights to the quantitative usage of knee compartments in activities of daily life. Methods : Prior to study in an osteoarthritic clinical population which may present with various complicating anatomical and physiological changes, we investigate knee acoustical emissions of able-bodied individuals during a varying width squat exercise which simulates loading asymmetries that would typically be seen in this clinical population. To that end, we present a novel method to quantify the directional bias of asymmetry between the medial and lateral compartment knee joint load in healthy individuals by recording knee acoustical emissions and analyzing them using a deep neural network in a subject independent model. We placed four miniature contact microphones on the medial and lateral sides of the patella on both the left and right leg. We compared the handcrafted audio features with the automated features extracted from the convolutional autoencoder which is an unsupervised model that learns the comprehensive representation of the input to determine whether these automated features can better represent the signal's characteristic in regard to the structural asymmetry of the knee joint. The input to the convolutional auto encoder (CAE) is a time-frequency representation and different types of these images such as spectrogram and scalogram are compared. We alsocompared the multi-sensor fusion approach with the performance of a single sensor to determine the robustness of using multiple sensors. Results : Using a representation learning based approach, we developed a subject independent classification model capable of classifying the asymmetry of the medial and lateral joint load across subjects (accuracy = 83%). Conclusion : The result indicates that wavelet coherence which is the time-frequency correlation of two signals using a wavelet transform yields the best accuracy. Significance : These findings suggest that acoustic signals could potentially quantify the direction of medial to lateral load distribution which would broaden the implications for wearable sensing technology for monitoring cartilage health and factors responsible for cartilage breakdown and assessing appropriate rehabilitation exercises without overloading on one side.


  • AdaptNet: Human Activity Recognition via Bilateral Domain Adaptation Using Semi-Supervised Deep Translation Networks

    by Sungtae An, Alessio Medda, Michael N. Sawka, Clayton J. Hutto, Mindy L. Millard-Stafford, Scott Appling, Kristine L. S. Richardson, Omer T. Inan

    This study demonstrates robust human activity recognition from a single triaxial accelerometer via bilateral domain adaptation using semi-supervised deep translation networks. Datasets were obtained from previously published studies: University of Michigan (Domain 1) and Georgia Institute of Technology (Domain 2) where triaxial accelerometry was obtained on subjects during defined conditions with the goal of recognizing standing rest, walking (level ground), walking (decline), and walking (incline) with and without stairs (activity classes). Collected accelerometer data was preprocessed then analyzed by AdaptNet, a deep translation network composed of Variational Autoencoders and Generative Adversarial Networks trained with additional cycle-consistency losses to combine information from two data domains over shared latent space. Visualization and quantitative analyses demonstrated that AdaptNet successfully reconstructs self-domain wavelet scalogram inputs and generates realistic cross-domain translations. We found AdaptNet provides up to 36 percentage points (0.75 compared to 0.39) better classification performance measured by average macro-F 1 score compared to the existing domain adaptation methods when a small amount of labeled data is provided for both domains. AdaptNet yielded more robust performance than other methods when the sensor placements are different across two domains. By enabling improved ability to fuse datasets with scarce and weak labels, AdaptNet provides valid recognition of real-world locomotor activities, which can be further utilized in digital health tools such as status assessment of patients with chronic diseases.


  • Unifying the Estimation of Blood Volume Decompensation Status in a Porcine Model of Relative and Absolute Hypovolemia Via Wearable Sensing

    by Jacob P. Kimball, Jonathan S. Zia, Sungtae An, Christopher Rolfes, Jin-Oh Hahn, Michael N. Sawka, Omer T. Inan

    Hypovolemia remains the leading cause of preventable death in trauma cases. Recent research has demonstrated that using noninvasive continuous waveforms rather than traditional vital signs improves accuracy in early detection of hypovolemia to assist in triage and resuscitation. This work evaluates random forest models trained on different subsets of data from a pig model (n = 6) of absolute (bleeding) and relative (nitroglycerin-induced vasodilation) progressive hypovolemia (to 20% decrease in mean arterial pressure) and resuscitation. Features for the models were derived from a multi-modal set of wearable sensors, comprised of the electrocardiogram (ECG), seismocardiogram (SCG) and reflective photoplethysmogram (RPPG) and were normalized to each subject.s baseline. The median RMSE between predicted and actual percent progression towards cardiovascular decompensation for the best model was 30.5% during the relative period, 16.8% during absolute and 22.1% during resuscitation. The least squares best fit line over the mean aggregated predictions had a slope of 0.65 and intercept of 12.3, with an R 2 value of 0.93. When transitioned to a binary classification problem to identify decompensation, this model achieved an AUROC of 0.80. This study: a) developed a global model incorporating ECG, SCG and RPPG features for estimating individual-specific decompensation from progressive relative and absolute hypovolemia and resuscitation; b) demonstrated SCG as the most important modality to predict decompensation; c) demonstrated efficacy of random forest models trained on different data subsets; and d) demonstrated adding training data from two discrete forms of hypovolemia increases prediction accuracy for the other form of hypovolemia and resuscitation.


  • Deep active learning for interictal ictal injury continuum EEG patterns

    by Wendong Ge, Jin Jing, Sungtae An, Aline Herlopian, Marcus Ng, Aaron F. Struck, Brian Appavu, Emily L. Johnson, Gamaleldin Osman, Hiba A. Haider, et al.