Operation of an Induction Generator Controlled by a VSI Circuit
- 1 June 2007
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21635137,p. 2661-2666
Abstract
The paper analyses the operation of an induction generator (IG) controlled by a voltage source inverter (VSI) circuit. This circuit performs both voltage and frequency regulation. The IG frequency is controlled by keeping constant the VSI synchronous frequency. For the IG voltage regulation two cascaded regulators are used, which have as reference the line voltage and the VSI DC voltage, respectively. The VSI also ensures a smooth voltage buildup during the start-up process. Simulations are made in order to investigate the reliability of such a configuration. In addition, experiments were carried out using a laboratory-scale prototype.Keywords
This publication has 6 references indexed in Scilit:
- STATCOM-Based Voltage Regulator for Self-Excited Induction Generator Feeding Nonlinear LoadsIEEE Transactions on Industrial Electronics, 2006
- Experimental evaluation of an isolated induction generator with voltage and frequency control2006
- Transient Analysis of Self-Excited Induction Generator With Electronic Load Controller (ELC) Supplying Static and Dynamic LoadsIEEE Transactions on Industry Applications, 2005
- An improved electronic load controller for self-excited induction generator in micro-hydel applications2004
- Induction-generator-based system providing regulated voltage with constant frequencyIEEE Transactions on Industrial Electronics, 2000
- Factors influencing the protection of small-to-medium size induction generatorsIEEE Transactions on Industry Applications, 1988