Abstract
Accurate dose calculation is essential to precision radiation treatment planning and this accuracy depends upon anatomic and tissue electron density information. Modern treatment planning inhomogeneity corrections use x-ray CT images and calibrated scales of tissue CT number to electron density to provide this information. The presence of metal in the volume scanned by an x-ray CT scanner causes metal induced image artefacts that influence CT numbers and thereby introduce errors in the radiation dose distribution calculated. This paper investigates the dosimetric improvement achieved by a previously proposed x-ray CT metal artefact suppression technique when the suppressed images of a patient with bilateral hip prostheses are used in commercial treatment planning systems for proton, electron or photon therapies. For all these beam types, this clinical image and treatment planning study reveals that the target may be severely underdosed if a metal artefact-contaminated image is used for dose calculations instead of the artefact suppressed one. Of the three beam types studied, the metal artefact suppression is most important for proton therapy dose calculations, intermediate for electron therapy and least important for x-ray therapy but still significant. The study of a water phantom having a metal rod simulating a hip prosthesis indicates that CT numbers generated after image processing for metal artefact suppression are accurate and thus dose calculations based on the metal artefact suppressed images will be of high fidelity.Keywords
This publication has 15 references indexed in Scilit:
- Calibration of CT Hounsfield units for radiotherapy treatment planning of patients with metallic hip prostheses: the use of the extended CT-scalePhysics in Medicine & Biology, 2003
- Accuracy of inhomogeneity correction in photon radiotherapy from CT scans with different settingsPhysics in Medicine & Biology, 2002
- A study on beams passing through hip prosthesis for pelvic radiation treatmentInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2001
- How accurate is a CT-based dose calculation on a pencil beam TPS for a patient with a metallic prosthesis?Physics in Medicine & Biology, 2001
- An electron density calibration phantom for CT-based treatment planning computersMedical Physics, 1992
- The electron density of bone for inhomogeneity correction in radiotherapy planning using CT numbersPhysics in Medicine & Biology, 1984
- The relation between x-ray CT numbers and charged particle stopping powers and its significance for radiotherapy treatment planningPhysics in Medicine & Biology, 1983
- A model for calculating the effects of small inhomogeneities on electron beam dose distributionsMedical Physics, 1980
- The direct use of CT numbers in radiotherapy dosage calculations for inhomogeneous mediaPhysics in Medicine & Biology, 1979
- A technique for calculating the influence of thin inhomogeneities on charged particle beamsMedical Physics, 1978