Age, sex, and lung volume dependence of dissolved xenon‐129 MRI gas exchange metrics
Open Access
- 10 May 2024
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (4) , 1471-1483
Abstract
Purpose: To characterize the dependence of Xe‐MRI gas transfer metrics upon age, sex, and lung volume in a group of healthy volunteers.Methods: Sixty‐five subjects with no history of chronic lung disease were assessed with 129Xe‐MRI using a four‐echo 3D radial spectroscopic imaging sequence and a dose of xenon titrated according to subject height that was inhaled from a lung volume of functional residual capacity (FRC). Imaging was repeated in 34 subjects at total lung capacity (TLC). Regional maps of the fractions of dissolved xenon in red blood cells (RBC), membrane (M), and airspace (Gas) were acquired at an isotropic resolution of 2 cm, from which global averages of the ratios RBC:M, RBC:Gas, and M:Gas were computed.Results: Data from 26 males and 36 females with a median age of 43 y (range: 20–69 y) were of sufficient quality to analyze. Age (p = 0.0006) and sex (p < 0.0001) were significant predictors for RBC:M, and a linear regression showed higher values and steeper decline in males: RBC:M(Males) = −0.00362 × Age + 0.60 (p = 0.01, R2 = 0.25); RBC:M(Females) = −0.00170 × Age + 0.44 (p = 0.02, R2 = 0.15). Similarly, age and sex were significant predictors for RBC:Gas but not for M:Gas. RBC:M, M:Gas and RBC:Gas were significantly lower at TLC than at FRC (plus inhaled volume), with an average 9%, 30% and 35% decrease, respectively.Conclusion: Expected age and sex dependence of pulmonary function concurs with 129Xe RBC:M imaging results, demonstrating that these variables must be considered when reporting Xe‐MRI metrics. Xenon doses and breathing maneuvers should be controlled due to the strong dependence of Xe‐MRI metrics upon lung volume.Keywords
Funding Information
- Engineering and Physical Sciences Research Council (EP/X025187/1)
- National Institute for Health and Care Research (COV‐LT2‐0049)
- Medical Research Council (MR/M008894/1)
This publication has 38 references indexed in Scilit:
- Repeatability of regional pulmonary functional metrics of Hyperpolarized 129Xe dissolved‐phase MRIJournal of Magnetic Resonance Imaging, 2019
- Assessment of flip angle–TR equivalence for standardized dissolved‐phase imaging of the lung with hyperpolarized 129Xe MRIMagnetic Resonance in Medicine, 2018
- Regional investigation of lung function and microstructure parameters by localized 129Xe chemical shift saturation recovery and dissolved‐phase imaging: A reproducibility studyMagnetic Resonance in Medicine, 2018
- Quantitative analysis of hyperpolarized129Xe gas transfer MRIMedical Physics, 2017
- 129Xe chemical shift in human blood and pulmonary blood oxygenation measurement in humans using hyperpolarized129Xe NMRMagnetic Resonance in Medicine, 2016
- Detecting pulmonary capillary blood pulsations using hyperpolarized xenon‐129 chemical shift saturation recovery (CSSR) MR spectroscopyMagnetic Resonance in Medicine, 2015
- Single‐breath clinical imaging of hyperpolarized 129xe in the airspaces, barrier, and red blood cells using an interleaved 3D radial 1‐point Dixon acquisitionMagnetic Resonance in Medicine, 2015
- Experimental validation of the hyperpolarized 129Xe chemical shift saturation recovery technique in healthy volunteers and subjects with interstitial lung diseaseMagnetic Resonance in Medicine, 2014
- Regional mapping of gas uptake by blood and tissue in the human lung using hyperpolarized xenon‐129 MRIJournal of Magnetic Resonance Imaging, 2013
- Volumetric spectroscopic imaging with spiral‐based k‐space trajectoriesMagnetic Resonance in Medicine, 1998