Graham Norquay
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Graham Norquay has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Jim Wild
POLARIS, Division of Clinical Medicine, School of Medicine & Population Health, Faculty of Health The University of Sheffield Sheffield UK
12 shared publications - Guilhem Jean Collier
POLARIS, Division of Clinical Medicine, School of Medicine & Population Health, Faculty of Health The University of Sheffield Sheffield UK
9 shared publications - Neil James Stewart
POLARIS, Division of Clinical Medicine, School of Medicine & Population Health, Faculty of Health The University of Sheffield Sheffield UK
6 shared publications - Madhwesha Rao
POLARIS, Imaging Sciences, Department of Infection, Immunity & Cardiovascular Disease University of Sheffield Sheffield UK
4 shared publications - Paul J. C. Hughes
POLARIS, Division of Clinical Medicine School of Medicine and Population Health, University of Sheffield Sheffield United Kingdom
4 shared publications - Alfred Arthur Roger Thompson
Division of Clinical Medicine, University of Sheffield, Sheffield, UK
3 shared publications
Latest Publications
- 30 May 2025
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 377, 107889
Finite element modeling of Rb-129Xe spin-exchange optical pumping and optimized Rb source distribution
- 30 May 2025
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 377, 107889
Finite element modeling of Rb-129Xe spin-exchange optical pumping and optimized Rb source distribution
- Open Access
- 24 December 2024
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 136 (24)
Evaluating modeling approaches for Rb-129Xe spin-exchange optical pumping and the effect of Rb vapor density heterogeneity
The applicability of commonly used 129Xe nuclear polarization (PXe) buildup models to large optical cell polarizers, which operate at lower gas pressures when compared to small cell polarizers for which spin-exchange optical pumping (SEOP) models were originally developed, has yet to be systematically evaluated. In addition, spatial heterogeneity of Rb vapor density ([Rb]) and its impact on SEOP in low pressure, large optical cell polarizers remains poorly understood. In this theoretical study, it was shown that 1D analytical and numerical PXe buildup models yield diverging PXe and critical flow rate values at low flow rates and high laser absorption, contributing to the discrepancy between theoretical and experimentally measured production rates. Additionally, it was found that [Rb] heterogeneity leads to lower PXe buildup and an undesirable increase in optimal cell temperature, while the optimal laser absorption remains relatively unchanged. The updated simulation framework presented here can be utilized to model other SEOP systems.
- 24 December 2024
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 136 (24)
Open AccessEvaluating modeling approaches for Rb-129Xe spin-exchange optical pumping and the effect of Rb vapor density heterogeneity
The applicability of commonly used 129Xe nuclear polarization (PXe) buildup models to large optical cell polarizers, which operate at lower gas pressures when compared to small cell polarizers for which spin-exchange optical pumping (SEOP) models were originally developed, has yet to be systematically evaluated. In addition, spatial heterogeneity of Rb vapor density ([Rb]) and its impact on SEOP in low pressure, large optical cell polarizers remains poorly understood. In this theoretical study, it was shown that 1D analytical and numerical PXe buildup models yield diverging PXe and critical flow rate values at low flow rates and high laser absorption, contributing to the discrepancy between theoretical and experimentally measured production rates. Additionally, it was found that [Rb] heterogeneity leads to lower PXe buildup and an undesirable increase in optimal cell temperature, while the optimal laser absorption remains relatively unchanged. The updated simulation framework presented here can be utilized to model other SEOP systems.
- Open Access
- 18 October 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (2) , 584-596
Mapping the amplitude and phase of dissolved 129Xe red blood cell signal oscillations with keyhole spectroscopic lung imaging
Purpose: To assess the regional amplitude and phase of dissolved 129Xe red blood cell (RBC) signal oscillations in the lung vasculature with keyhole spectroscopic imaging and to compare with previous methodology, which does not account for oscillation phase.Methods: 129Xe gas transfer was measured with a four‐echo 3D radial spectroscopic imaging sequence. Keyhole reconstruction‐based RBC signal oscillation amplitude mapping was applied retrospectively to data acquired from 28 healthy volunteers, 4 chronic thromboembolic pulmonary hypertension (CTEPH) patients, and 5 patients who were hospitalized due to COVID‐19 pneumonia and had residual lung abnormalities. Using a sliding window keyhole reconstruction, maps of RBC oscillation amplitude were corrected for regional phase difference. Repeatability of the phase‐adjusted oscillation amplitude was assessed in 8 healthy volunteers across three scans.Results: With sliding window keyhole reconstruction, regional phase differences were observed in the RBC signal oscillations: mean phase = (0.27 ± 0.19) rad in healthy volunteers, (0.24 ± 0.13) rad in CTEPH patients, and (0.33 ± 0.19) rad in patients with post‐COVID‐19 residual lung abnormality. The oscillation amplitude and phase maps were more heterogeneous (i.e., they showed increased coefficient of variation) for the CTEPH patients. The RBC oscillation amplitude was repeatable, and the mean three‐scan coefficient of variation was smaller when the phase adjustment was made (0.07 ± 0.04 compared with 0.16 ± 0.05).Conclusion: Sliding window keyhole reconstruction of radial dissolved 129Xe imaging reveals regional phase differences in the RBC oscillations, which are not captured when performing two phase keyhole reconstruction. This regional phase information may reflect the hemodynamic effect of the cardiac pulse wave in the pulmonary microvasculature.
- 18 October 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (2) , 584-596
Open AccessMapping the amplitude and phase of dissolved 129Xe red blood cell signal oscillations with keyhole spectroscopic lung imaging
Purpose: To assess the regional amplitude and phase of dissolved 129Xe red blood cell (RBC) signal oscillations in the lung vasculature with keyhole spectroscopic imaging and to compare with previous methodology, which does not account for oscillation phase.Methods: 129Xe gas transfer was measured with a four‐echo 3D radial spectroscopic imaging sequence. Keyhole reconstruction‐based RBC signal oscillation amplitude mapping was applied retrospectively to data acquired from 28 healthy volunteers, 4 chronic thromboembolic pulmonary hypertension (CTEPH) patients, and 5 patients who were hospitalized due to COVID‐19 pneumonia and had residual lung abnormalities. Using a sliding window keyhole reconstruction, maps of RBC oscillation amplitude were corrected for regional phase difference. Repeatability of the phase‐adjusted oscillation amplitude was assessed in 8 healthy volunteers across three scans.Results: With sliding window keyhole reconstruction, regional phase differences were observed in the RBC signal oscillations: mean phase = (0.27 ± 0.19) rad in healthy volunteers, (0.24 ± 0.13) rad in CTEPH patients, and (0.33 ± 0.19) rad in patients with post‐COVID‐19 residual lung abnormality. The oscillation amplitude and phase maps were more heterogeneous (i.e., they showed increased coefficient of variation) for the CTEPH patients. The RBC oscillation amplitude was repeatable, and the mean three‐scan coefficient of variation was smaller when the phase adjustment was made (0.07 ± 0.04 compared with 0.16 ± 0.05).Conclusion: Sliding window keyhole reconstruction of radial dissolved 129Xe imaging reveals regional phase differences in the RBC oscillations, which are not captured when performing two phase keyhole reconstruction. This regional phase information may reflect the hemodynamic effect of the cardiac pulse wave in the pulmonary microvasculature.
- Open Access
- 25 September 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (2) , 741-750
Compressed sensing reconstruction for high‐SNR, rapid dissolved 129Xe gas exchange MRI
Purpose: Three‐dimensional hyperpolarized 129Xe gas exchange imaging suffers from low SNR and long breath‐holds, which could be improved using compressed sensing (CS). The purpose of this work was to assess whether gas exchange ratio maps are quantitatively preserved in CS‐accelerated dissolved‐phase 129Xe imaging and to investigate the feasibility of CS‐dissolved 129Xe imaging with reduced‐cost natural abundance (NA) xenon.Methods: 129Xe gas exchange imaging was performed at 1.5 T with a multi‐echo spectroscopic imaging sequence. A CS reconstruction with an acceleration factor of 2 was compared retrospectively with conventional gridding reconstruction in a cohort of 16 healthy volunteers, 5 chronic obstructive pulmonary disease patients, and 23 patients who were hospitalized following COVID‐19 infection. Metrics of comparison included normalized mean absolute error, mean gas exchange ratio, and red blood cell (RBC) image SNR. Dissolved 129Xe CS imaging with NA xenon was assessed in 4 healthy volunteers.Results: CS reconstruction enabled acquisition time to be halved, and it reduced background noise. Median RBC SNR increased from 6 (2–18) to 11 (2–100) with CS, and there was strong agreement between CS and gridding mean ratio map values (R2 = 0.99). Image fidelity was maintained for gridding RBC SNR > 5, but below this, normalized mean absolute error increased nonlinearly with decreasing SNR. CS increased the mean SNR of NA 129Xe images 3‐fold.Conclusion: CS reconstruction of dissolved 129Xe imaging improved image quality with decreased scan time, while preserving key gas exchange metrics. This will benefit patients with breathlessness and/or low gas transfer and shows promise for NA‐dissolved 129Xe imaging.
- 25 September 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (2) , 741-750
Open AccessCompressed sensing reconstruction for high‐SNR, rapid dissolved 129Xe gas exchange MRI
Purpose: Three‐dimensional hyperpolarized 129Xe gas exchange imaging suffers from low SNR and long breath‐holds, which could be improved using compressed sensing (CS). The purpose of this work was to assess whether gas exchange ratio maps are quantitatively preserved in CS‐accelerated dissolved‐phase 129Xe imaging and to investigate the feasibility of CS‐dissolved 129Xe imaging with reduced‐cost natural abundance (NA) xenon.Methods: 129Xe gas exchange imaging was performed at 1.5 T with a multi‐echo spectroscopic imaging sequence. A CS reconstruction with an acceleration factor of 2 was compared retrospectively with conventional gridding reconstruction in a cohort of 16 healthy volunteers, 5 chronic obstructive pulmonary disease patients, and 23 patients who were hospitalized following COVID‐19 infection. Metrics of comparison included normalized mean absolute error, mean gas exchange ratio, and red blood cell (RBC) image SNR. Dissolved 129Xe CS imaging with NA xenon was assessed in 4 healthy volunteers.Results: CS reconstruction enabled acquisition time to be halved, and it reduced background noise. Median RBC SNR increased from 6 (2–18) to 11 (2–100) with CS, and there was strong agreement between CS and gridding mean ratio map values (R2 = 0.99). Image fidelity was maintained for gridding RBC SNR > 5, but below this, normalized mean absolute error increased nonlinearly with decreasing SNR. CS increased the mean SNR of NA 129Xe images 3‐fold.Conclusion: CS reconstruction of dissolved 129Xe imaging improved image quality with decreased scan time, while preserving key gas exchange metrics. This will benefit patients with breathlessness and/or low gas transfer and shows promise for NA‐dissolved 129Xe imaging.
- Open Access
- 23 September 2024
- Published by Elsevier in Journal of Magnetic Resonance Open
- Vol. 21
Measurement and modeling of xenon gas transfer in the human brain with 1H and hyperpolarized 129Xe MRI
- 23 September 2024
- Published by Elsevier in Journal of Magnetic Resonance Open
- Vol. 21
Open AccessMeasurement and modeling of xenon gas transfer in the human brain with 1H and hyperpolarized 129Xe MRI
- Open Access
- 18 August 2024
- Published by Wiley in Magnetic Resonance in Medicine
Improving Xenon‐129 lung ventilation image SNR with deep‐learning based image reconstruction
Purpose: To evaluate the feasibility and utility of a deep learning (DL)‐based reconstruction for improving the SNR of hyperpolarized 129Xe lung ventilation MRI.Methods: 129Xe lung ventilation MRI data acquired from patients with asthma and/or chronic obstructive pulmonary disease (COPD) were retrospectively reconstructed with a commercial DL reconstruction pipeline at five different denoising levels. Quantitative imaging metrics of lung ventilation including ventilation defect percentage (VDP) and ventilation heterogeneity index (VHI) were compared between each set of DL‐reconstructed images and alternative denoising strategies including: filtering, total variation denoising and higher‐order singular value decomposition. Structural similarity between the denoised and original images was assessed. In a prospective study, the feasibility of using SNR gains from DL reconstruction to allow natural‐abundance xenon MRI was evaluated in healthy volunteers.Results: 129Xe ventilation image SNR was improved with DL reconstruction when compared with conventionally reconstructed images. In patients with asthma and/or COPD, DL‐reconstructed images exhibited a slight positive bias in ventilation defect percentage (1.3% at 75% denoising) and ventilation heterogeneity index (˜1.4) when compared with conventionally reconstructed images. Additionally, DL‐reconstructed images preserved structural similarity more effectively than data denoised using alternative approaches. DL reconstruction greatly improved image SNR (greater than threefold), to a level that 129Xe ventilation imaging using natural‐abundance xenon appears feasible.Conclusion: DL‐based image reconstruction significantly improves 129Xe ventilation image SNR, preserves structural similarity, and leads to a minor bias in ventilation metrics that can be attributed to differences in the image sharpness. This tool should help facilitate cost‐effective 129Xe ventilation imaging with natural‐abundance xenon in the future.
- 18 August 2024
- Published by Wiley in Magnetic Resonance in Medicine
Open AccessImproving Xenon‐129 lung ventilation image SNR with deep‐learning based image reconstruction
Purpose: To evaluate the feasibility and utility of a deep learning (DL)‐based reconstruction for improving the SNR of hyperpolarized 129Xe lung ventilation MRI.Methods: 129Xe lung ventilation MRI data acquired from patients with asthma and/or chronic obstructive pulmonary disease (COPD) were retrospectively reconstructed with a commercial DL reconstruction pipeline at five different denoising levels. Quantitative imaging metrics of lung ventilation including ventilation defect percentage (VDP) and ventilation heterogeneity index (VHI) were compared between each set of DL‐reconstructed images and alternative denoising strategies including: filtering, total variation denoising and higher‐order singular value decomposition. Structural similarity between the denoised and original images was assessed. In a prospective study, the feasibility of using SNR gains from DL reconstruction to allow natural‐abundance xenon MRI was evaluated in healthy volunteers.Results: 129Xe ventilation image SNR was improved with DL reconstruction when compared with conventionally reconstructed images. In patients with asthma and/or COPD, DL‐reconstructed images exhibited a slight positive bias in ventilation defect percentage (1.3% at 75% denoising) and ventilation heterogeneity index (˜1.4) when compared with conventionally reconstructed images. Additionally, DL‐reconstructed images preserved structural similarity more effectively than data denoised using alternative approaches. DL reconstruction greatly improved image SNR (greater than threefold), to a level that 129Xe ventilation imaging using natural‐abundance xenon appears feasible.Conclusion: DL‐based image reconstruction significantly improves 129Xe ventilation image SNR, preserves structural similarity, and leads to a minor bias in ventilation metrics that can be attributed to differences in the image sharpness. This tool should help facilitate cost‐effective 129Xe ventilation imaging with natural‐abundance xenon in the future.
- Open Access
- 10 May 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (4) , 1471-1483
Age, sex, and lung volume dependence of dissolved xenon‐129 MRI gas exchange metrics
Purpose: To characterize the dependence of Xe‐MRI gas transfer metrics upon age, sex, and lung volume in a group of healthy volunteers.Methods: Sixty‐five subjects with no history of chronic lung disease were assessed with 129Xe‐MRI using a four‐echo 3D radial spectroscopic imaging sequence and a dose of xenon titrated according to subject height that was inhaled from a lung volume of functional residual capacity (FRC). Imaging was repeated in 34 subjects at total lung capacity (TLC). Regional maps of the fractions of dissolved xenon in red blood cells (RBC), membrane (M), and airspace (Gas) were acquired at an isotropic resolution of 2 cm, from which global averages of the ratios RBC:M, RBC:Gas, and M:Gas were computed.Results: Data from 26 males and 36 females with a median age of 43 y (range: 20–69 y) were of sufficient quality to analyze. Age (p = 0.0006) and sex (p < 0.0001) were significant predictors for RBC:M, and a linear regression showed higher values and steeper decline in males: RBC:M(Males) = −0.00362 × Age + 0.60 (p = 0.01, R2 = 0.25); RBC:M(Females) = −0.00170 × Age + 0.44 (p = 0.02, R2 = 0.15). Similarly, age and sex were significant predictors for RBC:Gas but not for M:Gas. RBC:M, M:Gas and RBC:Gas were significantly lower at TLC than at FRC (plus inhaled volume), with an average 9%, 30% and 35% decrease, respectively.Conclusion: Expected age and sex dependence of pulmonary function concurs with 129Xe RBC:M imaging results, demonstrating that these variables must be considered when reporting Xe‐MRI metrics. Xenon doses and breathing maneuvers should be controlled due to the strong dependence of Xe‐MRI metrics upon lung volume.
- 10 May 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (4) , 1471-1483
Open AccessAge, sex, and lung volume dependence of dissolved xenon‐129 MRI gas exchange metrics
Purpose: To characterize the dependence of Xe‐MRI gas transfer metrics upon age, sex, and lung volume in a group of healthy volunteers.Methods: Sixty‐five subjects with no history of chronic lung disease were assessed with 129Xe‐MRI using a four‐echo 3D radial spectroscopic imaging sequence and a dose of xenon titrated according to subject height that was inhaled from a lung volume of functional residual capacity (FRC). Imaging was repeated in 34 subjects at total lung capacity (TLC). Regional maps of the fractions of dissolved xenon in red blood cells (RBC), membrane (M), and airspace (Gas) were acquired at an isotropic resolution of 2 cm, from which global averages of the ratios RBC:M, RBC:Gas, and M:Gas were computed.Results: Data from 26 males and 36 females with a median age of 43 y (range: 20–69 y) were of sufficient quality to analyze. Age (p = 0.0006) and sex (p < 0.0001) were significant predictors for RBC:M, and a linear regression showed higher values and steeper decline in males: RBC:M(Males) = −0.00362 × Age + 0.60 (p = 0.01, R2 = 0.25); RBC:M(Females) = −0.00170 × Age + 0.44 (p = 0.02, R2 = 0.15). Similarly, age and sex were significant predictors for RBC:Gas but not for M:Gas. RBC:M, M:Gas and RBC:Gas were significantly lower at TLC than at FRC (plus inhaled volume), with an average 9%, 30% and 35% decrease, respectively.Conclusion: Expected age and sex dependence of pulmonary function concurs with 129Xe RBC:M imaging results, demonstrating that these variables must be considered when reporting Xe‐MRI metrics. Xenon doses and breathing maneuvers should be controlled due to the strong dependence of Xe‐MRI metrics upon lung volume.
- Open Access
- 6 February 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (6) , 2217-2226
Imaging gas‐exchange lung function and brain tissue uptake of hyperpolarized 129Xe using sampling density‐weighted MRSI
Purpose: Imaging of the different resonances of hyperpolarized 129Xe in the brain and lungs was performed using a 3D sampling density‐weighted MRSI technique in healthy volunteers.Methods: Four volunteers underwent dissolved‐phase hyperpolarized 129Xe imaging in the lung with the MRSI technique, which was designed to improve the point‐spread function while preserving SNR (1799 phase‐encoding steps, 14‐s breath hold, 2.1‐cm isotropic resolution). A frequency‐tailored RF excitation pulse was implemented to reliably excite both the 129Xe gas and dissolved phase (tissue/blood signal) with 0.1° and 10° flip angles, respectively. Images of xenon gas in the lung airspaces and xenon dissolved in lung tissue/blood were used to generate quantitative signal ratio maps. The method was also optimized and used for imaging dissolved resonances of 129Xe in the brain in 2 additional volunteers.Results: High‐quality regional spectra of hyperpolarized 129Xe were achieved in both the lung and the brain. Ratio maps of the different xenon resonances were obtained in the lung with sufficient SNR (> 10) at both 1.5 T and 3 T, making a triple Lorentzian fit possible and enabling the measurement of relaxation times and xenon frequency shifts on a voxel‐wise basis. The imaging technique was successfully adapted for brain imaging, resulting in the first demonstration of 3D xenon brain images with a 2‐cm isotropic resolution.Conclusion: Density‐weighted MRSI is an SNR and encoding‐efficient way to image 129Xe resonances in the lung and the brain, providing a valuable tool to quantify regional spectroscopic information.
- 6 February 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (6) , 2217-2226
Open AccessImaging gas‐exchange lung function and brain tissue uptake of hyperpolarized 129Xe using sampling density‐weighted MRSI
Purpose: Imaging of the different resonances of hyperpolarized 129Xe in the brain and lungs was performed using a 3D sampling density‐weighted MRSI technique in healthy volunteers.Methods: Four volunteers underwent dissolved‐phase hyperpolarized 129Xe imaging in the lung with the MRSI technique, which was designed to improve the point‐spread function while preserving SNR (1799 phase‐encoding steps, 14‐s breath hold, 2.1‐cm isotropic resolution). A frequency‐tailored RF excitation pulse was implemented to reliably excite both the 129Xe gas and dissolved phase (tissue/blood signal) with 0.1° and 10° flip angles, respectively. Images of xenon gas in the lung airspaces and xenon dissolved in lung tissue/blood were used to generate quantitative signal ratio maps. The method was also optimized and used for imaging dissolved resonances of 129Xe in the brain in 2 additional volunteers.Results: High‐quality regional spectra of hyperpolarized 129Xe were achieved in both the lung and the brain. Ratio maps of the different xenon resonances were obtained in the lung with sufficient SNR (> 10) at both 1.5 T and 3 T, making a triple Lorentzian fit possible and enabling the measurement of relaxation times and xenon frequency shifts on a voxel‐wise basis. The imaging technique was successfully adapted for brain imaging, resulting in the first demonstration of 3D xenon brain images with a 2‐cm isotropic resolution.Conclusion: Density‐weighted MRSI is an SNR and encoding‐efficient way to image 129Xe resonances in the lung and the brain, providing a valuable tool to quantify regional spectroscopic information.
- Open Access
Investigating Rubidium Density and Temperature Distributions in a High-Throughput 129Xe-Rb Spin-Exchange Optical Pumping Polarizer
Accurate knowledge of the rubidium (Rb) vapor density, , is necessary to correctly model the spin dynamics of Xe-Rb spin-exchange optical pumping (SEOP). Here we present a systematic evaluation of within a high-throughput Xe-Rb hyperpolarizer during continuous-flow SEOP. Near-infrared ( (D)/5 (D)) and violet (/6) atomic absorption spectroscopy was used to measure within 3.5 L cylindrical SEOP cells containing different spatial distributions and amounts of Rb metal. We were able to quantify deviation from the Beer-Lambert law at high optical depth for D and 6 absorption by comparison with measurements of the D and 6 absorption lines, respectively. D absorption deviates from the Beer-Lambert law at m whilst 5S absorption deviates from the Beer-Lambert law at m. The measured was used to estimate a Xe-Rb spin exchange cross section of m s, consistent with spin-exchange cross sections from the literature. Significant heterogeneity was observed in a SEOP cell containing 1 g of Rb localized at the back of the cell. While homogeneity was improved for a greater surface area of the Rb source distribution in the cell, or by using a Rb presaturator, the measured was consistently lower than that predicted by saturation Rb vapor density curves. Efforts to optimize and thermal management within spin polarizer systems are necessary to maximize potential future enhancements of this technology.Open AccessInvestigating Rubidium Density and Temperature Distributions in a High-Throughput 129Xe-Rb Spin-Exchange Optical Pumping Polarizer
Accurate knowledge of the rubidium (Rb) vapor density, , is necessary to correctly model the spin dynamics of Xe-Rb spin-exchange optical pumping (SEOP). Here we present a systematic evaluation of within a high-throughput Xe-Rb hyperpolarizer during continuous-flow SEOP. Near-infrared ( (D)/5 (D)) and violet (/6) atomic absorption spectroscopy was used to measure within 3.5 L cylindrical SEOP cells containing different spatial distributions and amounts of Rb metal. We were able to quantify deviation from the Beer-Lambert law at high optical depth for D and 6 absorption by comparison with measurements of the D and 6 absorption lines, respectively. D absorption deviates from the Beer-Lambert law at m whilst 5S absorption deviates from the Beer-Lambert law at m. The measured was used to estimate a Xe-Rb spin exchange cross section of m s, consistent with spin-exchange cross sections from the literature. Significant heterogeneity was observed in a SEOP cell containing 1 g of Rb localized at the back of the cell. While homogeneity was improved for a greater surface area of the Rb source distribution in the cell, or by using a Rb presaturator, the measured was consistently lower than that predicted by saturation Rb vapor density curves. Efforts to optimize and thermal management within spin polarizer systems are necessary to maximize potential future enhancements of this technology. - Open Access
Longitudinal lung function assessment of patients hospitalised with COVID-19 using 1 H and 129 Xe lung MRI
Introduction: Microvascular abnormalities and impaired gas transfer have been observed in patients with COVID-19. The progression of pathophysiological pulmonary changes during the post-acute period in these patients remains unclear. Methods: Patients who were hospitalised due to COVID-19 pneumonia underwent a pulmonary 1 H and 129 Xe MRI protocol at 6, 12, 25 and 51 weeks after hospital admission. The imaging protocol included: ultra-short echo time, dynamic contrast enhanced lung perfusion, 129 Xe lung ventilation, 129 Xe diffusion weighted and 129 Xe 3D spectroscopic imaging of gas exchange. Results: 9 patients were recruited and underwent MRI at 6 (n=9), 12 (n=9), 25 (n=6) and 51 (n=8) weeks after hospital admission. Patients with signs of interstitial lung damage at 3 months were excluded from this study. At 6 weeks after hospital admission, patients demonstrated impaired 129 Xe gas transfer (RBC:M) but normal lung microstructure (ADC, Lm D ). Minor ventilation abnormalities present in four patients were largely resolved in the 6–25 week period. At 12 week follow up, all patients with lung perfusion data available (n=6) showed an increase in both pulmonary blood volume and flow when compared to 6 weeks, though this was not statistically significant. At 12 week follow up, significant improvements in 129 Xe gas transfer were observed compared to 6-week examinations, however 129 Xe gas transfer remained abnormally low at weeks 12, 25 and 51. Changes in 129 Xe gas transfer correlated significantly with changes in pulmonary blood volume and TL CO Z-score. Conclusions: This study demonstrates that multinuclear MRI is sensitive to functional pulmonary changes in the follow up of patients who were hospitalised with COVID-19. Impairment of xenon transfer may indicate damage to the pulmonary microcirculation.
Open AccessLongitudinal lung function assessment of patients hospitalised with COVID-19 using 1 H and 129 Xe lung MRI
Introduction: Microvascular abnormalities and impaired gas transfer have been observed in patients with COVID-19. The progression of pathophysiological pulmonary changes during the post-acute period in these patients remains unclear. Methods: Patients who were hospitalised due to COVID-19 pneumonia underwent a pulmonary 1 H and 129 Xe MRI protocol at 6, 12, 25 and 51 weeks after hospital admission. The imaging protocol included: ultra-short echo time, dynamic contrast enhanced lung perfusion, 129 Xe lung ventilation, 129 Xe diffusion weighted and 129 Xe 3D spectroscopic imaging of gas exchange. Results: 9 patients were recruited and underwent MRI at 6 (n=9), 12 (n=9), 25 (n=6) and 51 (n=8) weeks after hospital admission. Patients with signs of interstitial lung damage at 3 months were excluded from this study. At 6 weeks after hospital admission, patients demonstrated impaired 129 Xe gas transfer (RBC:M) but normal lung microstructure (ADC, Lm D ). Minor ventilation abnormalities present in four patients were largely resolved in the 6–25 week period. At 12 week follow up, all patients with lung perfusion data available (n=6) showed an increase in both pulmonary blood volume and flow when compared to 6 weeks, though this was not statistically significant. At 12 week follow up, significant improvements in 129 Xe gas transfer were observed compared to 6-week examinations, however 129 Xe gas transfer remained abnormally low at weeks 12, 25 and 51. Changes in 129 Xe gas transfer correlated significantly with changes in pulmonary blood volume and TL CO Z-score. Conclusions: This study demonstrates that multinuclear MRI is sensitive to functional pulmonary changes in the follow up of patients who were hospitalised with COVID-19. Impairment of xenon transfer may indicate damage to the pulmonary microcirculation.