Use of a Hydroxyapatite-coated Stem in Patients with Dorr Type C Femoral Bone
- 1 December 2007
- journal article
- section i
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 465, 112-116
Abstract
Type C bone, as described by Dorr, exhibits both cellular and structural compromise, which presents a challenge for fixation of a total hip arthroplasty (THA). We evaluated the performance of the Omnifit® HA stem, a hydroxyapatite-coated titanium alloy stem, by retrospectively reviewing the clinical and radiographic data of 15 patients with femoral Type C bone who received the stem during primary THA between 1991 and 1994. The patients were followed a minimum of 9 years (mean, 11.5 years; range, 9-14 years). The average age at surgery was 54 years and the average body mass index was 28. Eight of the patients were men. The median Harris hip score was 94.5 points. Radiographically, two independent reviewers identified all patients as Type C bone. The average canal to calcar isthmus ratio was 0.74 (range, 0.65-0.95). At most recent followup, four patients demonstrated proximal osteolysis. Using plain radiography we detected no patients with distal osteolysis or subsidence. At 9 to 14 years, the stem has performed well in a selected series of patients with poor bone quality and the outcomes compare favorably with previously reported findings using this design of stem in other bone types. These results support the decision to use a hydroxyapatite-coated stem in patients with Type C bone. Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.Keywords
This publication has 15 references indexed in Scilit:
- Hydroxyapatite-coated Femoral ComponentsClinical Orthopaedics and Related Research, 2006
- The migration of femoral components after total hip replacement surgery: accuracy and precision of software-aided measurementsSkeletal Radiology, 2003
- Hydroxyapatite Femoral Stems for Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2001
- Hydroxyapatite in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1998
- Remodeling of Bone around Hydroxyapatite-Coated Femoral Stems*Journal of Bone and Joint Surgery, 1996
- Six-year results of hydroxyapatite-coated total hip replacementThe Journal of Bone and Joint Surgery. British volume, 1995
- Structural and cellular assessment of bone quality of proximal femurBone, 1993
- Hydroxylapatite coating of porous implants improves bone ingrowth and interface attachment strengthJournal of Biomedical Materials Research, 1992
- Ectopic Ossification Following Total Hip ReplacementJournal of Bone and Joint Surgery, 1973
- Traumatic Arthritis of the Hip after Dislocation and Acetabular FracturesJournal of Bone and Joint Surgery, 1969