Implications of temporal sampling in voltage imaging microscopy
Preprint
Abstract
Significance: Voltage imaging microscopy has emerged as a powerful tool to investigate neural activity both in vivo and in vitro. Various imaging approaches have been developed, including point-scanning, line-scanning and wide-field microscopes, however the effects of their different temporal sampling methods on signal fidelity have not yet been fully investigated. Aim: To provide an analysis of the inherent advantages and disadvantages of temporal sampling in scanning and wide-field microscopes and their effect on the fidelity of voltage spike detection. Approach: We develop a mathematical framework based on a mixture of analytical modeling and computer simulations with Monte-Carlo approaches. Results: Scanning microscopes outperform wide-field microscopes in low signal-to-noise conditions and when only a small subset of spikes needs to be detected. Wide-field microscopes outperform scanning microscopes when the measurement is temporally undersampled and a large fraction of the spikes needs to be detected. Both modalities converge in performance as sampling increases and the frame rate reaches the decay rate of the voltage indicator. Conclusions: Our work provides guidance for the selection of optimal temporal sampling parameters for voltage imaging. Most importantly it advises against using scanning voltage imaging microscopes at frame rates below 500 Hz.Keywords
All Related Versions
This publication has 16 references indexed in Scilit:
- Sustained deep-tissue voltage recording using a fast indicator evolved for two-photon microscopyCell, 2022
- Large-scale voltage imaging in behaving mice using targeted illuminationiScience, 2021
- Ultrafast Two-Photon Imaging of a High-Gain Voltage Indicator in Awake Behaving MiceCell, 2019
- Voltage imaging with genetically encoded indicatorsCurrent Opinion in Chemical Biology, 2017
- Bayes optimal template matching for spike sorting – combining fisher discriminant analysis with optimal filteringJournal of Computational Neuroscience, 2015
- An optimized fluorescent probe for visualizing glutamate neurotransmissionNature Methods, 2013
- Imaging neural activity in worms, flies and mice with improved GCaMP calcium indicatorsNature Methods, 2009
- Automatic spike detection based on adaptive template matching for extracellular neural recordingsJournal of Neuroscience Methods, 2007
- Online detection and sorting of extracellularly recorded action potentials in human medial temporal lobe recordings, in vivoJournal of Neuroscience Methods, 2006
- Using noise signature to optimize spike-sorting and to assess neuronal classification qualityJournal of Neuroscience Methods, 2002