Jakub Czuchnowski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jakub Czuchnowski has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Robert Prevedel
Cell Biology and Biophysics Unit, European Molecular Biology Laboratory Heidelberg, Germany; Developmental Biology, European Molecular Biology Laboratory Heidelberg, Germany; Molecular Medicine Partnership Unit (MMPU), European Molecular Biology Laborator
8 shared publications Jerome Mertz
Department of Biomedical Engineering Boston University 02215 Boston MA USA
3 shared publicationsBrandon Weissbourd
2 shared publicationsChuan Li
Boston University
2 shared publicationsHongli Ni
2 shared publications- Alba Diz-Muñoz
Cell Biology and Biophysics Unit, European Molecular Biology Laboratory, Heidelberg, Germany
1 shared publication
Latest Publications
- 4 August 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (16) , 29928
Versatile 3D space-variant deconvolution with measurement-free point spread function models
Deconvolution is the most widely used aberration correction technique in microscopy, however most techniques assume that the aberrations are the same for each point in the image, which is rarely true. Methods for tracking spatially varying aberrations require burdensome calibration or computation, or require symmetries in the aberration patterns. Here, we expand on existing modal deconvolution methods and demonstrate 3D fluorescence deconvolution in imaging systems that exhibit no simple symmetry by utilizing measurement-free point spread function models. Our method is based on a space-variant generalization of Richardson-Lucy deconvolution that makes use of point spread functions derived entirely by ray-tracing based on the optical system design. This enables a hybrid combination of physics-based modal deconvolution and simulation-based PSF modeling. Importantly, it obviates any requirement for guide stars or measurements for PSF calibration. We validate the performance of our method by applying it to snapshot multiplane imaging of both bead samples and biological specimens, and show that modal decomposition is a practical solution for deconvolving spatially varying aberrations that do not display clear symmetries.
- 4 August 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (16) , 29928
Versatile 3D space-variant deconvolution with measurement-free point spread function models
Deconvolution is the most widely used aberration correction technique in microscopy, however most techniques assume that the aberrations are the same for each point in the image, which is rarely true. Methods for tracking spatially varying aberrations require burdensome calibration or computation, or require symmetries in the aberration patterns. Here, we expand on existing modal deconvolution methods and demonstrate 3D fluorescence deconvolution in imaging systems that exhibit no simple symmetry by utilizing measurement-free point spread function models. Our method is based on a space-variant generalization of Richardson-Lucy deconvolution that makes use of point spread functions derived entirely by ray-tracing based on the optical system design. This enables a hybrid combination of physics-based modal deconvolution and simulation-based PSF modeling. Importantly, it obviates any requirement for guide stars or measurements for PSF calibration. We validate the performance of our method by applying it to snapshot multiplane imaging of both bead samples and biological specimens, and show that modal decomposition is a practical solution for deconvolving spatially varying aberrations that do not display clear symmetries.
- Open Access
- 1 March 2026
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (1) , 015075
Interrogation trajectory optimization for Fabry–Pérot based photoacoustic tomography
Fabry–Pérot based photoacoustic tomography (FP-PAT) is a promising all-optical imaging modality for a wide range of preclinical and clinical applications. However, there exist several challenges in routinely applying FP-PAT in time-critical experiments. Among those, the need for spectral tuning of the laser between each scan position can severely limit the effective imaging speed. Here, we present an interrogation trajectory optimization approach which allows to increase the overall speed in a way that is independent of the type of interrogation laser used as well as the FP quality. Our approach provides a way to tackle speed degradation caused by hardware limitations and simplify the use of FP-PAT systems.
- 1 March 2026
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (1) , 015075
Open AccessInterrogation trajectory optimization for Fabry–Pérot based photoacoustic tomography
Fabry–Pérot based photoacoustic tomography (FP-PAT) is a promising all-optical imaging modality for a wide range of preclinical and clinical applications. However, there exist several challenges in routinely applying FP-PAT in time-critical experiments. Among those, the need for spectral tuning of the laser between each scan position can severely limit the effective imaging speed. Here, we present an interrogation trajectory optimization approach which allows to increase the overall speed in a way that is independent of the type of interrogation laser used as well as the FP quality. Our approach provides a way to tackle speed degradation caused by hardware limitations and simplify the use of FP-PAT systems.
- Open Access
- 28 January 2026
Implications of temporal sampling in voltage imaging microscopy
Voltage imaging microscopy has emerged as a powerful tool to investigate neural activity both in vivo and in vitro. Various imaging approaches have been developed, including point-scanning, line-scanning and wide-field microscopes, however the effects of their different temporal sampling methods on signal fidelity have not yet been fully investigated. To provide an analysis of the inherent advantages and disadvantages of temporal sampling in scanning and wide-field microscopes and their effect on the fidelity of voltage spike detection. We develop a mathematical framework based on a mixture of analytical modeling and computer simulations with Monte-Carlo approaches. Scanning microscopes outperform wide-field microscopes in low signal-to-noise conditions and when only a small subset of spikes needs to be detected. Wide-field microscopes outperform scanning microscopes when the measurement is temporally undersampled and a large fraction of the spikes needs to be detected. Both modalities converge in performance as sampling increases and the frame rate reaches the decay rate of the voltage indicator. Our work provides guidance for the selection of optimal temporal sampling parameters for voltage imaging. Most importantly it advises against using scanning voltage imaging microscopes at frame rates below 500 Hz.
- 28 January 2026
Open AccessImplications of temporal sampling in voltage imaging microscopy
Voltage imaging microscopy has emerged as a powerful tool to investigate neural activity both in vivo and in vitro. Various imaging approaches have been developed, including point-scanning, line-scanning and wide-field microscopes, however the effects of their different temporal sampling methods on signal fidelity have not yet been fully investigated. To provide an analysis of the inherent advantages and disadvantages of temporal sampling in scanning and wide-field microscopes and their effect on the fidelity of voltage spike detection. We develop a mathematical framework based on a mixture of analytical modeling and computer simulations with Monte-Carlo approaches. Scanning microscopes outperform wide-field microscopes in low signal-to-noise conditions and when only a small subset of spikes needs to be detected. Wide-field microscopes outperform scanning microscopes when the measurement is temporally undersampled and a large fraction of the spikes needs to be detected. Both modalities converge in performance as sampling increases and the frame rate reaches the decay rate of the voltage indicator. Our work provides guidance for the selection of optimal temporal sampling parameters for voltage imaging. Most importantly it advises against using scanning voltage imaging microscopes at frame rates below 500 Hz.
- Open Access
Implications of temporal sampling in voltage imaging microscopy
Significance: Voltage imaging microscopy has emerged as a powerful tool to investigate neural activity both in vivo and in vitro. Various imaging approaches have been developed, including point-scanning, line-scanning and wide-field microscopes, however the effects of their different temporal sampling methods on signal fidelity have not yet been fully investigated. Aim: To provide an analysis of the inherent advantages and disadvantages of temporal sampling in scanning and wide-field microscopes and their effect on the fidelity of voltage spike detection. Approach: We develop a mathematical framework based on a mixture of analytical modeling and computer simulations with Monte-Carlo approaches. Results: Scanning microscopes outperform wide-field microscopes in low signal-to-noise conditions and when only a small subset of spikes needs to be detected. Wide-field microscopes outperform scanning microscopes when the measurement is temporally undersampled and a large fraction of the spikes needs to be detected. Both modalities converge in performance as sampling increases and the frame rate reaches the decay rate of the voltage indicator. Conclusions: Our work provides guidance for the selection of optimal temporal sampling parameters for voltage imaging. Most importantly it advises against using scanning voltage imaging microscopes at frame rates below 500 Hz.
Open AccessImplications of temporal sampling in voltage imaging microscopy
Significance: Voltage imaging microscopy has emerged as a powerful tool to investigate neural activity both in vivo and in vitro. Various imaging approaches have been developed, including point-scanning, line-scanning and wide-field microscopes, however the effects of their different temporal sampling methods on signal fidelity have not yet been fully investigated. Aim: To provide an analysis of the inherent advantages and disadvantages of temporal sampling in scanning and wide-field microscopes and their effect on the fidelity of voltage spike detection. Approach: We develop a mathematical framework based on a mixture of analytical modeling and computer simulations with Monte-Carlo approaches. Results: Scanning microscopes outperform wide-field microscopes in low signal-to-noise conditions and when only a small subset of spikes needs to be detected. Wide-field microscopes outperform scanning microscopes when the measurement is temporally undersampled and a large fraction of the spikes needs to be detected. Both modalities converge in performance as sampling increases and the frame rate reaches the decay rate of the voltage indicator. Conclusions: Our work provides guidance for the selection of optimal temporal sampling parameters for voltage imaging. Most importantly it advises against using scanning voltage imaging microscopes at frame rates below 500 Hz.
- Open Access
3D space-variant modal deconvolution with computed point spread functions
Deconvolution is the most widely used aberration correction technique in microscopy, however most techniques assume that the aberrations are the same for each point in the image, which is rarely true. Methods for tracking spatially varying aberrations require burdensome calibration or computation, or require symmetries in the aberration patterns. Here, we expand on existing modal deconvolution methods to demonstrate 3D fluorescence deconvolution in imaging systems that exhibit no simple symmetry. Our method is based on a space-variant generalization of Richardson-Lucy deconvolution that makes use of ZEMAX\textsuperscript{\textregistered}-derived point spread functions without the requirement of guide stars or calibration measurements. We validate the performance of our method by applying it to snapshot multiplane imaging of both bead samples and biological specimens, and show that modal decomposition is a practical solution for deconvolving spatially varying aberrations that do not display clear symmetries.
Open Access3D space-variant modal deconvolution with computed point spread functions
Deconvolution is the most widely used aberration correction technique in microscopy, however most techniques assume that the aberrations are the same for each point in the image, which is rarely true. Methods for tracking spatially varying aberrations require burdensome calibration or computation, or require symmetries in the aberration patterns. Here, we expand on existing modal deconvolution methods to demonstrate 3D fluorescence deconvolution in imaging systems that exhibit no simple symmetry. Our method is based on a space-variant generalization of Richardson-Lucy deconvolution that makes use of ZEMAX\textsuperscript{\textregistered}-derived point spread functions without the requirement of guide stars or calibration measurements. We validate the performance of our method by applying it to snapshot multiplane imaging of both bead samples and biological specimens, and show that modal decomposition is a practical solution for deconvolving spatially varying aberrations that do not display clear symmetries.
- Open Access
Interrogation trajectory optimisation for Fabry-Perot based photoacoustic tomography
Fabry-Pérot based photoacoustic tomography (FP-PAT) is a promising all-optical imaging modality for a wide range of preclinical and clinical applications. However, there exist several challenges in routinely applying FP-PAT in time-critical experiments. Among those, the need for spectral tuning of the laser between each scan position can severely limit the effective imaging speed. Here, we present an interrogation trajectory optimization approach which allows to increase the overall speed in a way that is independent of the type of interrogation laser used as well as the FP quality. Our approach provides a way to tackle speed degradation caused by hardware limitations and simplify the use of FP-PAT systems.
Open AccessInterrogation trajectory optimisation for Fabry-Perot based photoacoustic tomography
Fabry-Pérot based photoacoustic tomography (FP-PAT) is a promising all-optical imaging modality for a wide range of preclinical and clinical applications. However, there exist several challenges in routinely applying FP-PAT in time-critical experiments. Among those, the need for spectral tuning of the laser between each scan position can severely limit the effective imaging speed. Here, we present an interrogation trajectory optimization approach which allows to increase the overall speed in a way that is independent of the type of interrogation laser used as well as the FP quality. Our approach provides a way to tackle speed degradation caused by hardware limitations and simplify the use of FP-PAT systems.
- Open Access
- 13 September 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-15
Sensing their plasma membrane curvature allows migrating cells to circumvent obstacles
To navigate through diverse tissues, migrating cells must balance persistent self-propelled motion with adaptive behaviors to circumvent obstacles. We identify a curvature-sensing mechanism underlying obstacle evasion in immune-like cells. Specifically, we propose that actin polymerization at the advancing edge of migrating cells is inhibited by the curvature-sensitive BAR domain protein Snx33 in regions with inward plasma membrane curvature. The genetic perturbation of this machinery reduces the cells’ capacity to evade obstructions combined with faster and more persistent cell migration in obstacle-free environments. Our results show how cells can read out their surface topography and utilize actin and plasma membrane biophysics to interpret their environment, allowing them to adaptively decide if they should move ahead or turn away. On the basis of our findings, we propose that the natural diversity of BAR domain proteins may allow cells to tune their curvature sensing machinery to match the shape characteristics in their environment.
- 13 September 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-15
Open AccessSensing their plasma membrane curvature allows migrating cells to circumvent obstacles
To navigate through diverse tissues, migrating cells must balance persistent self-propelled motion with adaptive behaviors to circumvent obstacles. We identify a curvature-sensing mechanism underlying obstacle evasion in immune-like cells. Specifically, we propose that actin polymerization at the advancing edge of migrating cells is inhibited by the curvature-sensitive BAR domain protein Snx33 in regions with inward plasma membrane curvature. The genetic perturbation of this machinery reduces the cells’ capacity to evade obstructions combined with faster and more persistent cell migration in obstacle-free environments. Our results show how cells can read out their surface topography and utilize actin and plasma membrane biophysics to interpret their environment, allowing them to adaptively decide if they should move ahead or turn away. On the basis of our findings, we propose that the natural diversity of BAR domain proteins may allow cells to tune their curvature sensing machinery to match the shape characteristics in their environment.
- 14 December 2022
- Published by Optica Publishing Group in Optics Continuum
- Vol. 1 (12) , 2600-2606
Zernike mode rescaling extends capabilities of adaptive optics for microscopy
Zernike polynomials are widely used mathematical models of experimentally observed optical aberrations, and they have found widespread use in adaptive optic realizations that are used to correct wavefront aberrations. However, Zernike aberrations lose their orthogonality when used in combination with Gaussian beams and, as a consequence, start to cross-couple between each other, a phenomenon that does not occur for Zernike aberrations in plane waves. Here, we describe how the aberration radius (i.e. the radius of the beam relative to the active aperture of an active optical element) influences this cross-coupling of Zernike aberrations in a way that is distinct from simple truncation or balancing. Furthermore, we show that this effect can actually be harnessed to allow efficient compensation of higher-order aberrations using only low-order Zernike modes. This finding has important practical implications, as it suggests the possibility of using adaptive optics devices with low element numbers to compensate aberrations that would normally require more complex and expensive devices.
- 14 December 2022
- Published by Optica Publishing Group in Optics Continuum
- Vol. 1 (12) , 2600-2606
Zernike mode rescaling extends capabilities of adaptive optics for microscopy
Zernike polynomials are widely used mathematical models of experimentally observed optical aberrations, and they have found widespread use in adaptive optic realizations that are used to correct wavefront aberrations. However, Zernike aberrations lose their orthogonality when used in combination with Gaussian beams and, as a consequence, start to cross-couple between each other, a phenomenon that does not occur for Zernike aberrations in plane waves. Here, we describe how the aberration radius (i.e. the radius of the beam relative to the active aperture of an active optical element) influences this cross-coupling of Zernike aberrations in a way that is distinct from simple truncation or balancing. Furthermore, we show that this effect can actually be harnessed to allow efficient compensation of higher-order aberrations using only low-order Zernike modes. This finding has important practical implications, as it suggests the possibility of using adaptive optics devices with low element numbers to compensate aberrations that would normally require more complex and expensive devices.
- 16 November 2022
- Published by Optica Publishing Group in Optics Letters
- Vol. 47 (23) , 6089-6092
Transfer function asymmetry in Fabry–Perot-based optical pressure sensors
Optical resonators are some of the most promising optical devices for manufacturing high-performance pressure sensors for photoacoustic imaging. Among these, Fabry–Perot (FP)-based pressure sensors have been successfully used for a multitude of applications. However, critical performance aspects of FP-based pressure sensors have not been studied extensively, including the effects that system parameters such as beam diameter and cavity misalignment have on transfer function shape. Here, we discuss the possible origins of the transfer function asymmetry, ways to correctly estimate the FP pressure sensitivity under practical experimental conditions, as well as show the importance of proper assessments for real-world applications.
- 16 November 2022
- Published by Optica Publishing Group in Optics Letters
- Vol. 47 (23) , 6089-6092
Transfer function asymmetry in Fabry–Perot-based optical pressure sensors
Optical resonators are some of the most promising optical devices for manufacturing high-performance pressure sensors for photoacoustic imaging. Among these, Fabry–Perot (FP)-based pressure sensors have been successfully used for a multitude of applications. However, critical performance aspects of FP-based pressure sensors have not been studied extensively, including the effects that system parameters such as beam diameter and cavity misalignment have on transfer function shape. Here, we discuss the possible origins of the transfer function asymmetry, ways to correctly estimate the FP pressure sensitivity under practical experimental conditions, as well as show the importance of proper assessments for real-world applications.
- Open Access
- 5 April 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (04) , 046001-7
Comparing free-space and fiber-coupled detectors for Fabry–Pérot-based all-optical photoacoustic tomography
Significance: Highly sensitive detection is crucial for all-optical photoacoustic (PA) imaging. However, free-space optical detectors are prone to optical aberrations, which can degrade the pressure sensitivity and result in deteriorated image quality. While spatial mode-filtering has been proposed to alleviate these problems in Fabry–Pérot-based pressure sensors, their real functional advantage has never been properly investigated. Aim: We rigorously and quantitatively compare the performance of free-space and fiber-coupled detectors for Fabry–Pérot-based pressure sensors. Approach: We develop and characterize a quantitative correlative setup capable of simultaneous PA imaging using a free space and a fiber-coupled detector. Results: We found that fiber-coupled detectors are superior in terms of both signal level and image quality in realistic all-optical PA tomography settings. Conclusions: Our study has important practical implications in the field of PA imaging, as for most applications and implementations fiber-coupled detectors are relatively easy to employ since they do not require modifications to the core of the system but only to the peripherally located detector.
- 5 April 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (04) , 046001-7
Open AccessComparing free-space and fiber-coupled detectors for Fabry–Pérot-based all-optical photoacoustic tomography
Significance: Highly sensitive detection is crucial for all-optical photoacoustic (PA) imaging. However, free-space optical detectors are prone to optical aberrations, which can degrade the pressure sensitivity and result in deteriorated image quality. While spatial mode-filtering has been proposed to alleviate these problems in Fabry–Pérot-based pressure sensors, their real functional advantage has never been properly investigated. Aim: We rigorously and quantitatively compare the performance of free-space and fiber-coupled detectors for Fabry–Pérot-based pressure sensors. Approach: We develop and characterize a quantitative correlative setup capable of simultaneous PA imaging using a free space and a fiber-coupled detector. Results: We found that fiber-coupled detectors are superior in terms of both signal level and image quality in realistic all-optical PA tomography settings. Conclusions: Our study has important practical implications in the field of PA imaging, as for most applications and implementations fiber-coupled detectors are relatively easy to employ since they do not require modifications to the core of the system but only to the peripherally located detector.