Dosimetric assessment of conventional and advanced algorithms in clinical stereotactic radiotherapy
Open Access
- 24 August 2025
- journal article
- Published by Wiley in Precision Radiation Oncology
- Vol. 9 (3) , 192-201
Abstract
Purpose: To systematically compare the dosimetric performance of conventional (Ray Tracing, AAA) and advanced (Monte Carlo, Acuros XB) dose calculation algorithms across homogeneous and heterogeneous tissues in stereotactic radiotherapy (SRT) and stereotactic body radiotherapy (SBRT).Methods: A retrospective analysis of 125 SRT cases (brain: 50, lung: 20, liver: 20, spine: 35) was conducted using CyberKnife and Varian systems. Plans were originally created using Type B (Anisotropic Analytical Algorithm [AAA] and Ray Tracing) algorithms and were subsequently recalculated using Type C (Acuros XB and Monte Carlo) algorithms, while maintaining identical beam geometry and monitor units. Dosimetric parameters (D95%, Dmean, Dmax, CI, HI, GI) were evaluated. Validation included point dose measurements with Cheese Phantom and gamma index analysis using the PTW 1600 SRS Phantom.Results: In lung cases, Type B algorithms overestimated D95% by 14% compared to Monte Carlo, which reduced Dmean by 13.7% and CI by 25.8%. In liver, Acuros XB lowered Dmean by 21.4% with a 0.8% CI reduction. For spine, Monte Carlo reduced D95% by 3.4%, with a 1.1% drop in Dmean and stable CI. Brain cases showed minimal differences, with Monte Carlo increasing CI by 2.5% (1.19 vs. 1.16). Gamma pass rates exceeded 98% for Monte Carlo and Acuros XB, surpassing Ray Tracing and AAA (≤96%).Conclusion: Advanced algorithms demonstrated superior dose accuracy, homogeneity, and organs at risk (OAR) sparing in heterogeneous anatomical regions. Despite higher computational requirements, their clinical implementation is justified for SRT/SBRT planning. This study supports a site‐specific approach, advocating for advanced algorithm use in anatomically complex scenarios.Keywords
This publication has 28 references indexed in Scilit:
- Multi-organ segmentation of organ-at-risk (OAR's) of head and neck site using ensemble learning techniqueRadiography, 2024
- Clinical impact of the VOLO optimizer on treatment plan quality and clinical treatment efficiency for CyberKnifeJournal of Applied Clinical Medical Physics, 2020
- Comparison of five dose calculation algorithms in a heterogeneous media using design of experimentPhysica Medica, 2019
- A Randomized Phase 2 Study Comparing 2 Stereotactic Body Radiation Therapy Schedules for Medically Inoperable Patients With Stage I Peripheral Non-Small Cell Lung Cancer: NRG Oncology RTOG 0915 (NCCTG N0927)International Journal of Radiation Oncology - Biology - Physics (IJROBP), 2015
- 7. Prescribing, Recording, and ReportingJournal of the ICRU, 2014
- 4. Treatment Planning AlgorithmsJournal of the ICRU, 2014
- Dosimetric comparison of Acuros XB, AAA, and XVMC in stereotactic body radiotherapy for lung cancerMedical Physics, 2014
- Dosimetric impact of Acuros XB deterministic radiation transport algorithm for heterogeneous dose calculation in lung cancerMedical Physics, 2013
- Dosimetric Impact of Using the Acuros XB Algorithm for Intensity Modulated Radiation Therapy and RapidArc Planning in Nasopharyngeal CarcinomasInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2013
- Clinical Accuracy of the Respiratory Tumor Tracking System of the CyberKnife: Assessment by Analysis of Log FilesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009