Manindra Bhushan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Manindra Bhushan has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Abhay Kumar Singh
Department of Physics, GLA University, Mathura, India
1 shared publication - Abhinav Dewan
Rajiv Gandhi Canc Inst & Res Ctr, Dept Radiat Oncol, New Delhi, India
1 shared publication Anuj Vijay
Department of Physics, GLA University Mathura India
1 shared publication- Deepika Chauhan
Division of Biology, Kansas State University
1 shared publication - Dennis Mah
Procure Proton Therapy Center, Somerset, NJ
1 shared publication - Dominic Maes
Department of Radiation Oncology, Fred Hutchinson Cancer Center, Seattle, WA, USA; Department of Radiation Oncology, University of Washington, Seattle, WA, USA
1 shared publication
Latest Publications
- Open Access
- 24 August 2025
- Published by Wiley in Precision Radiation Oncology
- Vol. 9 (3) , 192-201
Dosimetric assessment of conventional and advanced algorithms in clinical stereotactic radiotherapy
Purpose: To systematically compare the dosimetric performance of conventional (Ray Tracing, AAA) and advanced (Monte Carlo, Acuros XB) dose calculation algorithms across homogeneous and heterogeneous tissues in stereotactic radiotherapy (SRT) and stereotactic body radiotherapy (SBRT).Methods: A retrospective analysis of 125 SRT cases (brain: 50, lung: 20, liver: 20, spine: 35) was conducted using CyberKnife and Varian systems. Plans were originally created using Type B (Anisotropic Analytical Algorithm [AAA] and Ray Tracing) algorithms and were subsequently recalculated using Type C (Acuros XB and Monte Carlo) algorithms, while maintaining identical beam geometry and monitor units. Dosimetric parameters (D95%, Dmean, Dmax, CI, HI, GI) were evaluated. Validation included point dose measurements with Cheese Phantom and gamma index analysis using the PTW 1600 SRS Phantom.Results: In lung cases, Type B algorithms overestimated D95% by 14% compared to Monte Carlo, which reduced Dmean by 13.7% and CI by 25.8%. In liver, Acuros XB lowered Dmean by 21.4% with a 0.8% CI reduction. For spine, Monte Carlo reduced D95% by 3.4%, with a 1.1% drop in Dmean and stable CI. Brain cases showed minimal differences, with Monte Carlo increasing CI by 2.5% (1.19 vs. 1.16). Gamma pass rates exceeded 98% for Monte Carlo and Acuros XB, surpassing Ray Tracing and AAA (≤96%).Conclusion: Advanced algorithms demonstrated superior dose accuracy, homogeneity, and organs at risk (OAR) sparing in heterogeneous anatomical regions. Despite higher computational requirements, their clinical implementation is justified for SRT/SBRT planning. This study supports a site‐specific approach, advocating for advanced algorithm use in anatomically complex scenarios.
- 24 August 2025
- Published by Wiley in Precision Radiation Oncology
- Vol. 9 (3) , 192-201
Open AccessDosimetric assessment of conventional and advanced algorithms in clinical stereotactic radiotherapy
Purpose: To systematically compare the dosimetric performance of conventional (Ray Tracing, AAA) and advanced (Monte Carlo, Acuros XB) dose calculation algorithms across homogeneous and heterogeneous tissues in stereotactic radiotherapy (SRT) and stereotactic body radiotherapy (SBRT).Methods: A retrospective analysis of 125 SRT cases (brain: 50, lung: 20, liver: 20, spine: 35) was conducted using CyberKnife and Varian systems. Plans were originally created using Type B (Anisotropic Analytical Algorithm [AAA] and Ray Tracing) algorithms and were subsequently recalculated using Type C (Acuros XB and Monte Carlo) algorithms, while maintaining identical beam geometry and monitor units. Dosimetric parameters (D95%, Dmean, Dmax, CI, HI, GI) were evaluated. Validation included point dose measurements with Cheese Phantom and gamma index analysis using the PTW 1600 SRS Phantom.Results: In lung cases, Type B algorithms overestimated D95% by 14% compared to Monte Carlo, which reduced Dmean by 13.7% and CI by 25.8%. In liver, Acuros XB lowered Dmean by 21.4% with a 0.8% CI reduction. For spine, Monte Carlo reduced D95% by 3.4%, with a 1.1% drop in Dmean and stable CI. Brain cases showed minimal differences, with Monte Carlo increasing CI by 2.5% (1.19 vs. 1.16). Gamma pass rates exceeded 98% for Monte Carlo and Acuros XB, surpassing Ray Tracing and AAA (≤96%).Conclusion: Advanced algorithms demonstrated superior dose accuracy, homogeneity, and organs at risk (OAR) sparing in heterogeneous anatomical regions. Despite higher computational requirements, their clinical implementation is justified for SRT/SBRT planning. This study supports a site‐specific approach, advocating for advanced algorithm use in anatomically complex scenarios.
- Open Access
- 30 September 2021
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 32 (3) , 70-81
Dosimetric Evaluation of Low-Dose Spillage Volumes for Head and Neck Cancer Using Intensity-Modulated Radiation Therapy and Volumetric Modulated Arc Therapy Treatment Techniques
Gourav Kumar , Manindra Bhushan , Lalit Kumar , Vimal Kishore , Kothanda Raman , Pawan Kumar , Soumitra Barik , Sandeep Purohit. Progress in Medical Physics 2021;32:70-81. https://doi.org/10.14316/pmp.2021.32.3.70
- 30 September 2021
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 32 (3) , 70-81
Open AccessDosimetric Evaluation of Low-Dose Spillage Volumes for Head and Neck Cancer Using Intensity-Modulated Radiation Therapy and Volumetric Modulated Arc Therapy Treatment Techniques
Gourav Kumar , Manindra Bhushan , Lalit Kumar , Vimal Kishore , Kothanda Raman , Pawan Kumar , Soumitra Barik , Sandeep Purohit. Progress in Medical Physics 2021;32:70-81. https://doi.org/10.14316/pmp.2021.32.3.70
- Open Access
- 1 September 2017
- Published by Elsevier in International Journal of Particle Therapy
- Vol. 4 (2) , 1-10
Dosimetric Comparison of Pencil-Beam Scanning and Photon-Based Radiation Therapy as a Boost in Carcinoma of Cervix
Purpose: Brachytherapy is essential for local treatment in cervical carcinoma, but some patients are not suitable for it. Presently, for these patients, the authors prefer a boost by using intensity-modulated radiation therapy (IMRT). The authors evaluated the dosimetric comparison of proton-modulated radiation therapy versus IMRT and volumetric-modulated arc therapy (VMAT) as a boost to know whether protons can replace photons. Patients and Methods: Five patients who received external beam radiation therapy to the pelvis by IMRT were reviewed. Three different plans were made, including pencil beam scanning (PBS), IMRT, and VMAT. The prescribed planning target volume (PTV) was 20 Gy in 4 fractions. The dose to 95% PTV (D95%), the conformity index, and the homogeneity index were evaluated for PTV. The Dmax, D2cc, and Dmean were evaluated for organs at risk along with the integral dose of normal tissue and organs at risk. Results: The PTV coverage was optimal and homogeneous with modulated protons ...
- 1 September 2017
- Published by Elsevier in International Journal of Particle Therapy
- Vol. 4 (2) , 1-10
Open AccessDosimetric Comparison of Pencil-Beam Scanning and Photon-Based Radiation Therapy as a Boost in Carcinoma of Cervix
Purpose: Brachytherapy is essential for local treatment in cervical carcinoma, but some patients are not suitable for it. Presently, for these patients, the authors prefer a boost by using intensity-modulated radiation therapy (IMRT). The authors evaluated the dosimetric comparison of proton-modulated radiation therapy versus IMRT and volumetric-modulated arc therapy (VMAT) as a boost to know whether protons can replace photons. Patients and Methods: Five patients who received external beam radiation therapy to the pelvis by IMRT were reviewed. Three different plans were made, including pencil beam scanning (PBS), IMRT, and VMAT. The prescribed planning target volume (PTV) was 20 Gy in 4 fractions. The dose to 95% PTV (D95%), the conformity index, and the homogeneity index were evaluated for PTV. The Dmax, D2cc, and Dmean were evaluated for organs at risk along with the integral dose of normal tissue and organs at risk. Results: The PTV coverage was optimal and homogeneous with modulated protons ...