Simple recipe for accurate T 2 quantification with multi spin-echo acquisitions
- 19 March 2014
- journal article
- research article
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 27 (6) , 567-577
Abstract
The quantification of magnetic resonance relaxation parameters T 1 and T 2 have the potential for improved disease detection and classification over standard clinical weighted imaging. Performing a mono-exponential fit on multi spin-echo (MSE) data provides quantitative T 2 values in a clinically acceptable scan-time. However, due to technical imperfections of refocusing pulses, stimulated echo contributions to the signals lead to significant deviations in the resulting T 2 values. In this work, a simple auto-calibrating correction procedure is presented, allowing the accurate estimation of T 2 from MSE acquisitions. Correction factors for T 2 values obtained from MSE acquisitions with a mono-exponential fit are derived from simulations following the extended phase graph formulation. A closed formula is given for the calculation of the required correction factors directly from the measured data itself. Simulations and phantom experiments show high accuracy of corrected T 2 values for a wide range of clinically relevant T 2 values and for different nominal refocusing flip angles. In addition, corrected T 2 maps of the human brain are presented. A simple recipe is provided to correct T 2 values obtained from MSE acquisitions via a mono-exponential fit for the influence of stimulated echoes. Since all required parameters are extracted from the data themselves, no additional acquisitions are required.Keywords
This publication has 16 references indexed in Scilit:
- Differentiation of hepatocellular carcinoma and hepatic metastasis from cysts and hemangiomas with calculated T2 relaxation times and the T1/T2 relaxation times ratioJournal of Magnetic Resonance Imaging, 2006
- Insights into brain microstructure from the T2 distributionMagnetic Resonance Imaging, 2006
- Optimized clinical T2 relaxometry with a standard CPMG sequenceJournal of Magnetic Resonance Imaging, 2006
- Whole-brain T2 mapping demonstrates occult abnormalities in focal epilepsyNeurology, 2005
- Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady stateMagnetic Resonance in Medicine, 2003
- Spatial variation of T2 in human articular cartilage.Radiology, 1997
- In vivo measurement of T2 distributions and water contents in normal human brainMagnetic Resonance in Medicine, 1997
- Tissue characterisation of intracranial tumours: the value of magnetisation transfer and conventional MRINeuroradiology, 1995
- Echoes—how to generate, recognize, use or avoid them in MR‐imaging sequences. Part I: Fundamental and not so fundamental properties of spin echoesConcepts in Magnetic Resonance, 1991
- Modified Spin-Echo Method for Measuring Nuclear Relaxation TimesReview of Scientific Instruments, 1958