Daniel Neumann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Daniel Neumann has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Felix A. Breuer
Research Center Magnetic Resonance Bavaria (MRB)
2 shared publications- Martin Blaimer
Fraunhofer Institute for Integrated Circuits IIS,Wrzburg,Germany
2 shared publications - Peter Michael Jakob
Experimental Physics 5 University of Würzburg Würzburg Germany
2 shared publications Mark A. Griswold
Department of Radiology University Hospitals of Cleveland and Biomedical Engineering, Case Western Reserve University Cleveland Ohio USA
1 shared publicationMichael Völker
Research Center Magnetic Resonance Bavaria (MRB) Würzburg Germany
1 shared publicationTobias Brandt
Department of Radiation Oncology Friedrich‐Alexander‐University Erlangen‐Nuremberg Erlangen Germany
1 shared publication
Latest Publications
- 19 March 2014
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 27 (6) , 567-577
Simple recipe for accurate T 2 quantification with multi spin-echo acquisitions
The quantification of magnetic resonance relaxation parameters T 1 and T 2 have the potential for improved disease detection and classification over standard clinical weighted imaging. Performing a mono-exponential fit on multi spin-echo (MSE) data provides quantitative T 2 values in a clinically acceptable scan-time. However, due to technical imperfections of refocusing pulses, stimulated echo contributions to the signals lead to significant deviations in the resulting T 2 values. In this work, a simple auto-calibrating correction procedure is presented, allowing the accurate estimation of T 2 from MSE acquisitions. Correction factors for T 2 values obtained from MSE acquisitions with a mono-exponential fit are derived from simulations following the extended phase graph formulation. A closed formula is given for the calculation of the required correction factors directly from the measured data itself. Simulations and phantom experiments show high accuracy of corrected T 2 values for a wide range of clinically relevant T 2 values and for different nominal refocusing flip angles. In addition, corrected T 2 maps of the human brain are presented. A simple recipe is provided to correct T 2 values obtained from MSE acquisitions via a mono-exponential fit for the influence of stimulated echoes. Since all required parameters are extracted from the data themselves, no additional acquisitions are required.
- 19 March 2014
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 27 (6) , 567-577
Simple recipe for accurate T 2 quantification with multi spin-echo acquisitions
The quantification of magnetic resonance relaxation parameters T 1 and T 2 have the potential for improved disease detection and classification over standard clinical weighted imaging. Performing a mono-exponential fit on multi spin-echo (MSE) data provides quantitative T 2 values in a clinically acceptable scan-time. However, due to technical imperfections of refocusing pulses, stimulated echo contributions to the signals lead to significant deviations in the resulting T 2 values. In this work, a simple auto-calibrating correction procedure is presented, allowing the accurate estimation of T 2 from MSE acquisitions. Correction factors for T 2 values obtained from MSE acquisitions with a mono-exponential fit are derived from simulations following the extended phase graph formulation. A closed formula is given for the calculation of the required correction factors directly from the measured data itself. Simulations and phantom experiments show high accuracy of corrected T 2 values for a wide range of clinically relevant T 2 values and for different nominal refocusing flip angles. In addition, corrected T 2 maps of the human brain are presented. A simple recipe is provided to correct T 2 values obtained from MSE acquisitions via a mono-exponential fit for the influence of stimulated echoes. Since all required parameters are extracted from the data themselves, no additional acquisitions are required.
- Open Access
- 16 January 2014
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 72 (6) , 1680-1686
Reducing contrast contamination in radial turbo‐spin‐echo acquisitions by combining a narrow‐band KWIC filter with parallel imaging
Purpose Cartesian turbo spin‐echo (TSE) and radial TSE images are usually reconstructed by assembling data containing different contrast information into a single k‐space. This approach results in mixed contrast contributions in the images, which may reduce their diagnostic value. The goal of this work is to improve the image contrast from radial TSE acquisitions by reducing the contribution of signals with undesired contrast information. Methods Radial TSE acquisitions allow the reconstruction of multiple images with different T2 contrasts using the k‐space weighted image contrast (KWIC) filter. In this work, the image contrast is improved by reducing the band‐width of the KWIC filter. Data for the reconstruction of a single image are selected from within a small temporal range around the desired echo time. The resulting dataset is undersampled and, therefore, an iterative parallel imaging algorithm is applied to remove aliasing artifacts. Results Radial TSE images of the human brain reconstructed with the proposed method show an improved contrast when compared with Cartesian TSE images or radial TSE images with conventional KWIC reconstructions. Conclusion The proposed method provides multi‐contrast images from radial TSE data with contrasts similar to multi spin‐echo images. Contaminations from unwanted contrast weightings are strongly reduced. Magn Reson Med 72:1680–1686, 2014.
- 16 January 2014
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 72 (6) , 1680-1686
Open AccessReducing contrast contamination in radial turbo‐spin‐echo acquisitions by combining a narrow‐band KWIC filter with parallel imaging
Purpose Cartesian turbo spin‐echo (TSE) and radial TSE images are usually reconstructed by assembling data containing different contrast information into a single k‐space. This approach results in mixed contrast contributions in the images, which may reduce their diagnostic value. The goal of this work is to improve the image contrast from radial TSE acquisitions by reducing the contribution of signals with undesired contrast information. Methods Radial TSE acquisitions allow the reconstruction of multiple images with different T2 contrasts using the k‐space weighted image contrast (KWIC) filter. In this work, the image contrast is improved by reducing the band‐width of the KWIC filter. Data for the reconstruction of a single image are selected from within a small temporal range around the desired echo time. The resulting dataset is undersampled and, therefore, an iterative parallel imaging algorithm is applied to remove aliasing artifacts. Results Radial TSE images of the human brain reconstructed with the proposed method show an improved contrast when compared with Cartesian TSE images or radial TSE images with conventional KWIC reconstructions. Conclusion The proposed method provides multi‐contrast images from radial TSE data with contrasts similar to multi spin‐echo images. Contaminations from unwanted contrast weightings are strongly reduced. Magn Reson Med 72:1680–1686, 2014.