Mock circulatory loops used for testing cardiac assist devices: A review of computational and experimental models
Authors:
- 28 September 2021
- journal article
- review article
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 44 (11) , 793-806
Abstract
Heart failure is a major health risk, and with limited availability of donor organs, there is an increasing need for developing cardiac assist devices (CADs). Mock circulatory loops (MCL) are an important in-vitro test platform for CAD’s performance assessment and optimisation. The MCL is a lumped parameter model constructed out of hydraulic and mechanical components aiming to simulate the native cardiovascular system (CVS) as closely as possible. Further development merged MCLs and numerical circulatory models to improve flexibility and accuracy of the system; commonly known as hybrid MCLs. A total of 128 MCLs were identified in a literature research until 25 September 2020. It was found that the complexity of the MCLs rose over the years, recent MCLs are not only capable of mimicking the healthy and pathological conditions, but also implemented cerebral, renal and coronary circulations and autoregulatory responses. Moreover, the development of anatomical models made flow visualisation studies possible. Mechanical MCLs showed excellent controllability and repeatability, however, often the CVS was overly simplified or lacked autoregulatory responses. In numerical MCLs the CVS is represented with a higher order of lumped parameters compared to mechanical test rigs, however, complex physiological aspects are often simplified. In hybrid MCLs complex physiological aspects are implemented in the hydraulic part of the system, whilst the numerical model represents parts of the CVS that are too difficult to represent by mechanical components per se. This review aims to describe the advances, limitations and future directions of the three types of MCLs.Keywords
Funding Information
- EPSRC Centre for Doctoral Training in Medical Imaging
- magAssist Inc
This publication has 116 references indexed in Scilit:
- Numerical simulation of left ventricular assist device implantations: Comparing the ascending and the descending aorta cannulationsMedical Engineering & Physics, 2013
- Effects of Intra‐Aortic Balloon Pump Timing on Baroreflex Activities in a Closed‐Loop Cardiovascular Hybrid ModelArtificial Organs, 2012
- A Controller for a Miniature Intra-Aortic Ventricular Assist DeviceArtificial Organs, 2010
- The use of computational fluid dynamics in the development of ventricular assist devicesMedical Engineering & Physics, 2010
- Flow Analysis of Ventricular Assist Device Inflow and Outflow Cannula Positioning Using a Naturally Shaped Ventricle and Aortic BranchArtificial Organs, 2010
- A Mock Circulatory System With Physiological Distribution of Terminal Resistance and Compliance: Application for Testing the Intra‐Aortic Balloon PumpArtificial Organs, 2010
- A new pulse duplicator with a passive fill ventricle for analysis of cardiac dynamicsJournal of Artificial Organs, 2010
- Numerical Modeling of Hemodynamics with Pulsatile Impeller Pump SupportAnnals of Biomedical Engineering, 2010
- Past, Present, and Future of Long‐Term Mechanical Cardiac Support in AdultsJournal of Cardiac Surgery, 2008
- Construction of an Artificial Heart Pump Performance Test SystemCardiovascular Engineering, 2006