Using a microfluidic device for 1 l DNA microarray hybridization in 500 s
Authors:
Open Access
- 28 April 2005
- journal article
- research article
- Published by Oxford University Press (OUP) in Nucleic Acids Research
- Vol. 33 (8) , e78
Abstract
This work describes a novel and simple modification of the current microarray format. It reduces the sample/reagent volume to 1 μl and the hybridization time to 500 s. Both 20mer and 80mer oligonucleotide probes and singly labeled 20mer and 80mer targets, representative of the T-cell acute lymphocytic leukemia 1 (TAL1) gene, have been used to elucidate the performance of this hybridization approach. In this format, called shuttle hybridization, a conventional flat glass DNA microarray is integrated with a PMMA microfluidic chip to reduce the sample and reagent consumption to 1/100 of that associated with the conventional format. A serpentine microtrench is designed and fabricated on a PMMA chip using a widely available CO2 laser scriber. The trench spacing is compatible with the inter-spot distance in standard microarrays. The microtrench chip and microarray chip are easily aligned and assembled manually so that the microarray is integrated with a microfluidic channel. Discrete sample plugs are employed in the microchannel for hybridization. Flowing through the microchannel with alternating depths and widths scrambles continuous sample plug into discrete short plugs. These plugs are shuttled back and forth along the channel, sweeping over microarray probes while re-circulation mixing occurs inside the plugs. Integrating the microarrays into the microfluidic channel reduces the DNA–DNA hybridization time from 18 h to 500 s. Additionally, the enhancement of DNA hybridization reaction by the microfluidic device is investigated by determining the coefficient of variation (CV), the growth rate of the hybridization signal and the ability to discriminate single-base mismatch. Detection limit of 19 amol was obtained for shuttle hybridization. A 1 μl target was used to hybridize with an array that can hold 5000 probes.Keywords
This publication has 25 references indexed in Scilit:
- Ultrasonic Mixing in Microfluidic Channels Using Integrated TransducersAnalytical Chemistry, 2004
- Modeling of DNA hybridization kinetics for spatially resolved biochipsAnalytical Biochemistry, 2003
- Fluorescent labelling of cRNA for microarray applicationsNucleic Acids Research, 2003
- A Microfluidic System for Controlling Reaction Networks in TimeAngewandte Chemie International Edition, 2003
- Assessing unmodified 70-mer oligonucleotide probe performance on glass-slide microarraysGenome Biology, 2003
- Factors influencing cDNA microarray hybridization on silylated glass slidesAnalytical Biochemistry, 2002
- Chaotic Mixer for MicrochannelsScience, 2002
- Chemiluminescence Detection for Hybridization Assays on the Flow-Thru Chip, a Three-Dimensional Microchannel BiochipAnalytical Chemistry, 2001
- Comparison between Different Strategies of Covalent Attachment of DNA to Glass Surfaces to Build DNA MicroarraysAnalytical Biochemistry, 2000
- Dissociation kinetics of 19 base paired oligonucleotide-DNA duplexes containing different single mismatched base pairsNucleic Acids Research, 1987