First Year On-Orbit Calibration of the Chinese Environmental Trace Gas Monitoring Instrument Onboard GaoFen-5
- 1 December 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Geoscience and Remote Sensing
- Vol. 58 (12) , 8531-8540
Abstract
Environmental trace gas monitoring instrument (EMI) onboard GaoFen-5 was launched in May 2018 and has successfully operated on-orbit for more than a year. EMI contains four grating spectrometers, covering wavelengths in the range 240-710 nm with a spectral resolution of 0.3-0.5 nm, and enables one-day global coverage. For EMI on-orbit calibration, two onboard solar diffusers (SD), one surface reflectance aluminum diffuser, and one quartz volume diffuser (QVD) are used to measure solar spectra. The solar spectra are used to perform accurate spectral and radiometric calibrations. EMI on-orbit spectral calibration contains wavelength calibration and instrument spectral response function (ISRF), both of which are the key quantities in trace gas retrievals based on differential optical absorption spectroscopy (DOAS) analysis. The wavelength calibration is performed using the Fraunhofer lines in the solar spectrum, and the ISRF parameters are obtained by fitting high-resolution and EMI-measured solar spectra. Based on the known solar irradiation and characteristic of SD, SD radiance can be calculated and is used for EMI on-orbit radiometric calibration. The radiometric calibration also determines the absolute Earth reflectance spectra that are used as inputs for atmospheric retrieval algorithms. For EMI on-orbit radiometric monitoring, aluminum diffuser is used as reference SD to monitor QVD degradation. An internal white light source is used to detect pixel performance and monitor radiometric throughput.Keywords
Funding Information
- National Natural Science Foundation of China (41705016)
- Natural Science Foundation of Anhui Province (1808085QD114)
This publication has 15 references indexed in Scilit:
- On-Orbit Characterization of the MODIS SDSM Screen for Solar Diffuser Degradation EstimationIEEE Transactions on Geoscience and Remote Sensing, 2017
- In-flight performance of the Ozone Monitoring InstrumentAtmospheric Measurement Techniques, 2017
- Parameterizing the instrumental spectral response function and its changes by a super-Gaussian and its derivativesAtmospheric Measurement Techniques, 2017
- The GOME-2 instrument on the Metop series of satellites: instrument design, calibration, and level 1 data processing – an overviewAtmospheric Measurement Techniques, 2016
- Effect of AO/UV/RD exposure on spaceborne diffusers: a comparative experimentApplied Optics, 2015
- TROPOMI on the ESA Sentinel-5 Precursor: A GMES mission for global observations of the atmospheric composition for climate, air quality and ozone layer applicationsRemote Sensing of Environment, 2012
- An In-Orbit Radiometric Calibration Method of the Geostationary Ocean Color ImagerIEEE Transactions on Geoscience and Remote Sensing, 2010
- An improved high-resolution solar reference spectrum for earth's atmosphere measurements in the ultraviolet, visible, and near infraredJournal of Quantitative Spectroscopy and Radiative Transfer, 2010
- On-Orbit Calibration and Performance of Aqua MODIS Reflective Solar BandsIEEE Transactions on Geoscience and Remote Sensing, 2009
- The ozone monitoring instrumentIEEE Transactions on Geoscience and Remote Sensing, 2006