Yu Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yu Wang has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Fuqi Si
Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, Anhui, China
2 shared publications - Minjie Zhao
Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Sciences, Chinese Academy of Sciences, Hefei 230031, China
2 shared publications - Cheng Liu
Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, 230026, China
1 shared publication - Fan Lu
Anhui Institute of Optics and Fine Mechanics Chinese Academy of Science 230031 Hefei ,China
1 shared publication - Fang Lin
University of Science and Technology of China 230031 Hefei China
1 shared publication Haijin Zhou
Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China
1 shared publication
Latest Publications
- 1 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Geoscience and Remote Sensing
- Vol. 58 (12) , 8531-8540
First Year On-Orbit Calibration of the Chinese Environmental Trace Gas Monitoring Instrument Onboard GaoFen-5
Environmental trace gas monitoring instrument (EMI) onboard GaoFen-5 was launched in May 2018 and has successfully operated on-orbit for more than a year. EMI contains four grating spectrometers, covering wavelengths in the range 240-710 nm with a spectral resolution of 0.3-0.5 nm, and enables one-day global coverage. For EMI on-orbit calibration, two onboard solar diffusers (SD), one surface reflectance aluminum diffuser, and one quartz volume diffuser (QVD) are used to measure solar spectra. The solar spectra are used to perform accurate spectral and radiometric calibrations. EMI on-orbit spectral calibration contains wavelength calibration and instrument spectral response function (ISRF), both of which are the key quantities in trace gas retrievals based on differential optical absorption spectroscopy (DOAS) analysis. The wavelength calibration is performed using the Fraunhofer lines in the solar spectrum, and the ISRF parameters are obtained by fitting high-resolution and EMI-measured solar spectra. Based on the known solar irradiation and characteristic of SD, SD radiance can be calculated and is used for EMI on-orbit radiometric calibration. The radiometric calibration also determines the absolute Earth reflectance spectra that are used as inputs for atmospheric retrieval algorithms. For EMI on-orbit radiometric monitoring, aluminum diffuser is used as reference SD to monitor QVD degradation. An internal white light source is used to detect pixel performance and monitor radiometric throughput.
- 1 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Geoscience and Remote Sensing
- Vol. 58 (12) , 8531-8540
First Year On-Orbit Calibration of the Chinese Environmental Trace Gas Monitoring Instrument Onboard GaoFen-5
Environmental trace gas monitoring instrument (EMI) onboard GaoFen-5 was launched in May 2018 and has successfully operated on-orbit for more than a year. EMI contains four grating spectrometers, covering wavelengths in the range 240-710 nm with a spectral resolution of 0.3-0.5 nm, and enables one-day global coverage. For EMI on-orbit calibration, two onboard solar diffusers (SD), one surface reflectance aluminum diffuser, and one quartz volume diffuser (QVD) are used to measure solar spectra. The solar spectra are used to perform accurate spectral and radiometric calibrations. EMI on-orbit spectral calibration contains wavelength calibration and instrument spectral response function (ISRF), both of which are the key quantities in trace gas retrievals based on differential optical absorption spectroscopy (DOAS) analysis. The wavelength calibration is performed using the Fraunhofer lines in the solar spectrum, and the ISRF parameters are obtained by fitting high-resolution and EMI-measured solar spectra. Based on the known solar irradiation and characteristic of SD, SD radiance can be calculated and is used for EMI on-orbit radiometric calibration. The radiometric calibration also determines the absolute Earth reflectance spectra that are used as inputs for atmospheric retrieval algorithms. For EMI on-orbit radiometric monitoring, aluminum diffuser is used as reference SD to monitor QVD degradation. An internal white light source is used to detect pixel performance and monitor radiometric throughput.
- Open Access
- 1 January 2017
- Published by Atlantis Press SARL
Design of Stepper Motor Control Circuit with Adjustable Torque
- 1 January 2017
- Published by Atlantis Press SARL
Open AccessDesign of Stepper Motor Control Circuit with Adjustable Torque
- 26 October 2015
- Published by Optica Publishing Group in Applied Optics
- Vol. 54 (31) , 9157-9166
Effect of AO/UV/RD exposure on spaceborne diffusers: a comparative experiment
The environmental measuring instrument (EMI) is a nadir-viewing wide-field imaging spectrometer, which adopts spaceborne diffusers in in-flight calibration systems, including an aluminum diffuser and a quartz volume diffuser. Spaceborne diffusers, are the key components of in-flight calibration systems, and are used to introduce sunlight into the EMI. Hemispheric reflectance and bidirectional reflectance distribution function were experimentally measured to analyze spaceborne diffuser performance. Radiation exposure experiments on atomic oxygen, UV, and radiation dose of the spaceborne diffusers were performed at ground level because the EMI works in low Earth orbit space environments. Effects of radiation exposure on spaceborne diffusers were discussed in detail. Protective methods were introduced to reduce the effects of the space environment, and an in-orbit monitoring method was also proposed.
- 26 October 2015
- Published by Optica Publishing Group in Applied Optics
- Vol. 54 (31) , 9157-9166
Effect of AO/UV/RD exposure on spaceborne diffusers: a comparative experiment
The environmental measuring instrument (EMI) is a nadir-viewing wide-field imaging spectrometer, which adopts spaceborne diffusers in in-flight calibration systems, including an aluminum diffuser and a quartz volume diffuser. Spaceborne diffusers, are the key components of in-flight calibration systems, and are used to introduce sunlight into the EMI. Hemispheric reflectance and bidirectional reflectance distribution function were experimentally measured to analyze spaceborne diffuser performance. Radiation exposure experiments on atomic oxygen, UV, and radiation dose of the spaceborne diffusers were performed at ground level because the EMI works in low Earth orbit space environments. Effects of radiation exposure on spaceborne diffusers were discussed in detail. Protective methods were introduced to reduce the effects of the space environment, and an in-orbit monitoring method was also proposed.