Echocardiographic assessment of left ventricular outflow tract diameter in preterm infants
Open Access
- 1 November 2014
- journal article
- research article
- Published by Wiley in Australasian Journal of Ultrasound in Medicine
- Vol. 17 (4) , 146-149
Abstract
Introduction: Left ventricular output (LVO) measurement is an important part of the echocardiographic assessment of cardiac function in preterm infants. The accurate measurement of left ventricular outflow tract diameter (LVOD) is key to the calculation of LVO. Given the lack of an appropriate gold standard, we used right ventricular output (RVO) as the comparator and sought to identify the most accurate method of determining LVO in preterm infants. Methods: We studied stable preterm infants without significant cardiac shunts. LVOD was measured at the aortic valve, the aortic sinus and at the sinotubular junction. LVOs were calculated and the precision and accuracy of each was determined relative to the RVO using the Bland-Altman method. Results: 52 infants were included in this analysis. The mean difference between RVO and LVO was largest when LVOD was measured at the aortic valve and aortic sinus, +106 and −115 ml/kg/min, respectively, and smallest when measured at the sinotubular junction, 9 ml/kg/min. Limits of agreement between RVO and LVO were narrowest when LVOD was measured at the STJ. Conclusion: LVOD measurement at the sinotubular junction provides more precise and accurate measurement of LVO, in comparison to RVO, than measurement at the aortic valve or the aortic sinus.Keywords
This publication has 21 references indexed in Scilit:
- The Methodology of Doppler-Derived Central Blood Flow Measurements in Newborn InfantsInternational Journal of Pediatrics, 2012
- Targeted Neonatal Echocardiography in the Neonatal Intensive Care Unit: Practice Guidelines and Recommendations for TrainingJournal of the American Society of Echocardiography, 2011
- Haemodynamically unstable preterm infant: an unresolved management conundrumEuropean Journal of Pediatrics, 2011
- Functional cardiac MRI in preterm and term newbornsArchives of Disease in Childhood - Fetal and Neonatal Edition, 2010
- Cardiac output measurement in newborn infants using the ultrasonic cardiac output monitor: an assessment of agreement with conventional echocardiography, repeatability and new user experienceArchives of Disease in Childhood - Fetal and Neonatal Edition, 2010
- Central blood flow measurements in stable preterm infants after the transitional periodArchives of Disease in Childhood - Fetal and Neonatal Edition, 2010
- Nasal Continuous Positive Airway Pressure (n-CPAP) Does Not Change Cardiac Output in Preterm InfantsAmerican Journal of Perinatology, 2008
- Influence of sampling site and flow area on cardiac output measurements by Doppler echocardiographyJACC, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Noninvasive Measurement of Cardiac Output in Healthy Preterm and Term Newborn InfantsAmerican Journal of Perinatology, 1984