Incidence of Undetectable, Measurable, and Increased Cardiac Troponin I Concentrations Above the 99th Percentile Using a High-Sensitivity vs a Contemporary Assay in Patients Presenting to the Emergency Department
Authors:
Open Access
- 1 August 2016
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 62 (8) , 1115-1119
Abstract
INTRODUCTION: We compared the incidence of undetectable [below the limit of detection (LoD)], measurable (LoD to 99th percentile), and increased cardiac troponin I (cTnI) concentrations above the 99th percentile between Abbott high-sensitivity cTnI (hs-cTnI) and contemporary cTnI assays in a US emergency department population. METHODS: Patients (n = 2100) presenting to the emergency department who had serial cTnI (0, 3, 6, 9 h) measurements ordered on clinical indication were enrolled. Contemporary cTnI [Abbott Architect used clinically; 99th percentile: 0.030 μg/L (30 ng/L)] and hs-cTnI [Abbott investigational; sex-specific 99th percentiles: female (F) 16 ng/L, male (M) 34 ng/L] assays simultaneously measured fresh EDTA plasma. RESULTS: The hs-cTnI assay measured fewer undetectable cTnI concentrations compared to the contemporary cTnI assay across baseline (F: 31% vs 47%, M: 22% vs 40%) and serial (F: 21% vs 46%; M: 19% vs 54%) measurements. Conversely, the proportion of measurable cTnI concentrations was higher using hs-cTnI compared to contemporary cTnI assay across both baseline (F: 46% vs 31%; M: 60% vs 33%) and serial (F: 48% vs 28%; M: 83% vs 40%) measurements. The overall proportion of patients with increased cTnI concentrations above the 99th percentile was not significantly different between the contemporary (31%) and hs-cTnI (26%) assays (P = 0.09). CONCLUSIONS: In patients presenting to the emergency department, the use of the Abbott hs-cTnI assay provides clinicians with more numeric cTnI concentrations. This occurs via a shift from results below the LoD to those between the LoD and the 99th percentile and does not increase in the number of cTnI concentrations above the 99th percentile.Keywords
Funding Information
- Abbott Laboratories
- Minneapolis Medical Research Foundation
This publication has 17 references indexed in Scilit:
- Present and Future of Cardiac Troponin in Clinical Practice: A Paradigm Shift to High-Sensitivity AssaysThe American Journal of Medicine, 2016
- Direct comparison of clinical decision limits for cardiac troponin T and IHeart, 2016
- Sex-specific versus overall cut points for a high sensitivity troponin I assay in predicting 1-year outcomes in emergency patients presenting with chest painHeart, 2016
- High-sensitivity cardiac troponin I at presentation in patients with suspected acute coronary syndrome: a cohort studyThe Lancet, 2015
- The utility of presentation and 4-hour high sensitivity troponin I to rule-out acute myocardial infarction in the emergency departmentClinical Biochemistry, 2015
- Diagnosis of Type 1 and Type 2 Myocardial Infarction Using a High-Sensitivity Cardiac Troponin I Assay with Sex-Specific 99th Percentiles Based on the Third Universal Definition of Myocardial Infarction Classification SystemClinical Chemistry, 2015
- High sensitivity cardiac troponin and the under-diagnosis of myocardial infarction in women: prospective cohort studyBMJ, 2015
- Undetectable High-Sensitivity Cardiac Troponin T Level in the Emergency Department and Risk of Myocardial InfarctionJACC, 2014
- Avoiding the Imminent Plague of TroponinitisJACC, 2014
- Determination of 19 Cardiac Troponin I and T Assay 99th Percentile Values from a Common Presumably Healthy PopulationClinical Chemistry, 2012