  • Clinical Evaluation of a New Point-of-Care System for Chemistry Panel Testing

    by Sara A Love, Karen Schulz, Penney Stack, Sharifa Abdirizak, Maniphone Souriyayong, Ruchika Malhotra, Clarke Xu, Prasad V A Pamidi

    Background: GEM Premier ChemSTAT™ is a point-of-care (POC) system that measures Na+, K+, Ca++, Cl−, glucose, hematocrit, creatinine, blood urea nitrogen (BUN), tCO2, pH, pCO2, and lactate from a single whole blood specimen, providing rapid results in POC settings such as the emergency department (ED). Accurate measurements of creatinine in whole blood and reporting of estimated glomerular filtration rate (eGFR) can minimize adverse effects of contrast-induced nephropathy. Methods: Heparinized whole blood specimens from the ED were analyzed on the ChemSTAT by POC staff. Method comparison was performed against the cobas Integra c501 for creatinine, BUN, and tCO2, and against the GEM Premier 4000 for all other analytes. Precision was conducted with whole blood specimens assayed in triplicate over 6 days. Creatinine results from whole blood and plasma were used for eGFR, by isotope dilution mass spectrometry-traceable Modification of Diet in Renal Disease and Chronic Kidney Disease Epidemiology Collaboration equations, and eGFR concordance was assessed. Results: Creatinine, BUN, and tCO2 correlated well with plasma samples on the cobas, and all other analytes correlated well with whole blood specimens on the GEM Premier 4000 across the tested sample ranges. The regression slope was 0.951 to 1.047, along with a correlation coefficient (r) of ≥0.982 for all analytes. The pooled within-sample precision was 0% to 2.5% for all analytes. Conclusions: ChemSTAT demonstrated a strong correlation with the comparative methods and excellent precision. The system's analytical performance and continuous quality management make it suitable for use in the ED to provide rapid reliable test results, which could minimize the time to treatment and improve ED efficiency.


  • Heroin‐related Deaths from the Hennepin County Medical Examiner's Office from 2004 Through 2015

    by Sara A. Love, Jessica Lelinski, Julie Kloss, Owen Middleton, Fred S. Apple

    Over the past two decades, prescription and illicit opioid use has led to changes in public health policy to address the increasing number of opioid‐related deaths. The purpose of this study was to review cases from Hennepin County Medical Examiner's Office between 2004 through 2015 where heroin was listed as a significant contributor or as the cause of death. We identified 322 heroin‐related deaths, which were predominantly male (255; 79%). 6‐Monoacetylmorphine (6‐MAM) median (range) concentrations were as follows: blood (n = 7), 0.010 (0.006–0.078) mg/L; urine (n = 30), 0.359 (0.009–1.75) mg/L; and vitreous humor (n = 31), 0.034 (0.004–0.24) mg/L. Free morphine was measurable in 273 cases and the percent free morphine (range), when grouped by COD, was opioid (n = 124), 28% (2.2%–92%), and mixed drug toxicity (n = 135), 35.3% (1.5%–100%); (p < 0.01). Quantitation of 6‐MAM in blood and vitreous humor, along with a free to total morphine ratio >26%, was useful in establishing heroin‐related deaths.


  • Urine Creatinine Concentrations in Drug Monitoring Participants and Hospitalized Patients

    by Sara A. Love, Jesse C. Seegmiller, Julie Kloss, Fred S. Apple

    Urine drug testing is commonly performed in both clinical and forensic arenas for screening, monitoring and compliance purposes. We sought to determine if urine creatinine concentrations in monitoring program participants were significantly different from hospital in-patients and out-patients undergoing urine drug testing. We retrospectively reviewed urine creatinine submitted in June through December 2015 for all specimens undergoing urine drug testing. The 20,479 creatinine results were categorized as hospitalized patients (H) and monitoring/compliance groups for pain management (P), legal (L) or recovery (R). Median creatinine concentrations (interquartile range, mg/dL) were significantly different (P < 0.001) between groups: H 126 (122–136); P 138 (137–143); L 147 (144–154); R 95 (92–97). In the two groups subject to on-demand sampling time pressures, median creatinine concentrations were significantly lower in the R vs. L group (P<0.001). In conclusion, recovery (R) participants have more dilute specimens, reflected by significantly lower creatinine concentration and may indicate participants’ attempts to tamper with their drug test results through dilution means.


  • Open Access

    Incidence of Undetectable, Measurable, and Increased Cardiac Troponin I Concentrations Above the 99th Percentile Using a High-Sensitivity vs a Contemporary Assay in Patients Presenting to the Emergency Department

    by Sara A Love, Yader Sandoval, Stephen W Smith, Jennifer Nicholson, Jing Cao, Ranka Ler, Karen Schulz, Fred S Apple

    INTRODUCTION: We compared the incidence of undetectable [below the limit of detection (LoD)], measurable (LoD to 99th percentile), and increased cardiac troponin I (cTnI) concentrations above the 99th percentile between Abbott high-sensitivity cTnI (hs-cTnI) and contemporary cTnI assays in a US emergency department population. METHODS: Patients (n = 2100) presenting to the emergency department who had serial cTnI (0, 3, 6, 9 h) measurements ordered on clinical indication were enrolled. Contemporary cTnI [Abbott Architect used clinically; 99th percentile: 0.030 μg/L (30 ng/L)] and hs-cTnI [Abbott investigational; sex-specific 99th percentiles: female (F) 16 ng/L, male (M) 34 ng/L] assays simultaneously measured fresh EDTA plasma. RESULTS: The hs-cTnI assay measured fewer undetectable cTnI concentrations compared to the contemporary cTnI assay across baseline (F: 31% vs 47%, M: 22% vs 40%) and serial (F: 21% vs 46%; M: 19% vs 54%) measurements. Conversely, the proportion of measurable cTnI concentrations was higher using hs-cTnI compared to contemporary cTnI assay across both baseline (F: 46% vs 31%; M: 60% vs 33%) and serial (F: 48% vs 28%; M: 83% vs 40%) measurements. The overall proportion of patients with increased cTnI concentrations above the 99th percentile was not significantly different between the contemporary (31%) and hs-cTnI (26%) assays (P = 0.09). CONCLUSIONS: In patients presenting to the emergency department, the use of the Abbott hs-cTnI assay provides clinicians with more numeric cTnI concentrations. This occurs via a shift from results below the LoD to those between the LoD and the 99th percentile and does not increase in the number of cTnI concentrations above the 99th percentile.