Beam's‐eye‐view imaging during non‐coplanar lung SBRT
- 1 December 2015
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 42 (12) , 6776-6783
Abstract
Purpose: Beam's‐eye‐view (BEV) imaging with an electronic portal imaging device (EPID) can be performed during lung stereotactic body radiation therapy (SBRT) to monitor the tumor location in real‐time. Image quality for each patient and treatment field depends on several factors including the patient anatomy and the gantry and couch angles. The authors investigated the angular dependence of automatic tumor localization during non‐coplanar lung SBRT delivery.Methods: All images were acquired at a frame rate of 12 Hz with an amorphous silicon EPID. A previously validated markerless lung tumor localization algorithm was employed with manual localization as the reference. From ten SBRT patients, 12 987 image frames of 123 image sequences acquired at 48 different gantry–couch rotations were analyzed. δ was defined by the position difference of the automatic and manual localization.Results: Regardless of the couch angle, the best tracking performance was found in image sequences with a gantry angle within 20° of 250° (δ = 1.40 mm). Image sequences acquired with gantry angles of 150°, 210°, and 350° also led to good tracking performances with δ = 1.77–2.00 mm. Overall, the couch angle was not correlated with the tracking results. Among all the gantry–couch combinations, image sequences acquired at (θ = 30°, ϕ = 330°), (θ = 210°, ϕ = 10°), and (θ = 250°, ϕ = 30°) led to the best tracking results with δ = 1.19–1.82 mm. The worst performing combinations were (θ = 90° and 230°, ϕ = 10°) and (θ = 270°, ϕ = 30°) with δ > 3.5 mm. However, 35% (17/48) of the gantry–couch rotations demonstrated substantial variability in tracking performances between patients. For example, the field angle (θ = 70°, ϕ = 10°) was acquired for five patients. While the tracking errors were ≤1.98 mm for three patients, poor performance was found for the other two patients with δ ≥ 2.18 mm, leading to average tracking error of 2.70 mm. Only one image sequence was acquired for all other gantry–couch rotations (δ = 1.18–10.29 mm).Conclusions: Non‐coplanar beams with gantry–couch rotation of (θ = 30°, ϕ = 330°), (θ = 210°, ϕ = 10°), and (θ = 250°, ϕ = 30°) have the highest accuracy for BEV lung tumor localization. Additionally, gantry angles of 150°, 210°, 250°, and 350° also offer good tracking performance. The beam geometries (θ = 90° and 230°, ϕ = 10°) and (θ = 270°, ϕ = 30°) are associated with substantial automatic localization errors. Overall, lung tumor visibility and tracking performance were patient dependent for a substantial number of the gantry–couch angle combinations studied.Keywords
Funding Information
- National Institutes of Health (NIH) (R01CA188446-01)
- National Institutes of Health (R01CA188446-01)
- National Institutes of Health (R01CA188446-01)
This publication has 24 references indexed in Scilit:
- Geometric uncertainty of 2D projection imaging in monitoring 3D tumor motionPhysics in Medicine & Biology, 2007
- Optimal number of beams for stereotactic body radiotherapy of lung and liver lesionsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Radiotherapy of Mobile TumorsSeminars in Radiation Oncology, 2006
- The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)Medical Physics, 2006
- Clinical outcomes of a phase I/II study of 48 Gy of stereotactic body radiotherapy in 4 fractions for primary lung cancer using a stereotactic body frameInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- Stereotactic body radiation therapy of early-stage non–small-cell lung carcinoma: Phase I studyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- Treatment planning of stereotactic radiotherapy for solitary lung tumorInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- Stereotactic radiotherapy for primary lung cancer and pulmonary metastases: A noninvasive treatment approach in medically inoperable patientsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2004
- Stereotactic single-dose radiotherapy of stage I non–small-cell lung cancer (NSCLC)International Journal of Radiation Oncology - Biology - Physics (IJROBP), 2003
- Small‐volume image‐guided radiotherapy using hypofractionated, coplanar, and noncoplanar multiple fields for patients with inoperable Stage I nonsmall cell lung carcinomasCancer, 2002