Impact of contact force sensing technology on outcome of catheter ablation of idiopathic pre-mature ventricular contractions originating from the outflow tracts
- 18 November 2020
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 23 (4) , 603-609
Abstract
Aims: Catheter ablation of frequent idiopathic pre-mature ventricular contractions (PVC) is increasingly performed. While potential benefits of contact force (CF)-sensing technology for atrial fibrillation ablation have been assessed in several studies, the impact of CF-sensing on ventricular arrhythmia ablation remains unknown. This study aimed to compare outcomes of idiopathic outflow tract PVC ablation when using standard ablation catheters as opposed to CF-sensing catheters. Methods and results: In a retrospective multi-centre study, unselected patients undergoing catheter ablation of idiopathic outflow tract PVCs between 2013 and 2016 were enrolled. All procedures were performed using irrigated-tip ablation catheters and a 3D electro-anatomical mapping system. Sustained ablation success was defined as a ≥80% reduction of pre-procedural PVC burden determined by 24 h Holter ECG during follow-up. Overall, 218 patients were enrolled (median age 52 years, 51% males). Baseline and procedural data were similar in the standard ablation (24%) and the CF-sensing group (76%). Overall, the median PVC burden decreased from 21% (IQR 10–30%) before ablation to 0.2% (IQR 0–3.0%) after a median follow-up of 2.3 months (IQR 1.4–3.9 months). The rates of both acute (91% vs. 91%, P = 0.94) and sustained success (79% vs. 74%, P = 0.44) were similar in the standard ablation and the CF-sensing groups. No differences were observed in subgroups according to arrhythmia origin from the RVOT (65%) or LVOT (35%). Complications were rare (1.8%) and evenly distributed between the two groups. Conclusion: The use of CF-sensing technology is not associated with increased success rate nor decreased complication rate in idiopathic outflow tract PVC ablation.Keywords
Funding Information
- Goldschmidt-Jacobson Foundation
- Cardiovascular Research Foundation Basel
- Swiss National Science Foundation
- Swiss National Science Foundation
- Swiss Heart Foundation
This publication has 20 references indexed in Scilit:
- 2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmiasEP Europace, 2019
- Role of Contact Force Sensing in Catheter Ablation of Cardiac ArrhythmiasJACC: Clinical Electrophysiology, 2018
- Contact force sensing for ablation of persistent atrial fibrillation: A randomized, multicenter trialHeart Rhythm, 2018
- Use of contact force sensing technology during radiofrequency ablation reduces recurrence of atrial fibrillation: A systematic review and meta-analysisHeart Rhythm, 2015
- Multicenter Outcomes for Catheter Ablation of Idiopathic Premature Ventricular ComplexesJACC: Clinical Electrophysiology, 2015
- Surgical cryoablation for ventricular tachyarrhythmia arising from the left ventricular outflow tract regionHeart Rhythm, 2015
- Neurohormonal, Structural, and Functional Recovery Pattern After Premature Ventricular Complex Ablation Is Independent of Structural Heart Disease Status in Patients With Depressed Left Ventricular Ejection FractionJACC, 2013
- Reasons for failed ablation for idiopathic right ventricular outflow tract-like ventricular arrhythmiasHeart Rhythm, 2013
- A novel radiofrequency ablation catheter using contact force sensing: Toccata studyHeart Rhythm, 2012
- Area Under the Real‐Time Contact Force Curve (Force–Time Integral) Predicts Radiofrequency Lesion Size in an In Vitro Contractile ModelJournal of Cardiovascular Electrophysiology, 2010