An Investigation of Stochastic Variance Reduction Algorithms for Relative Difference Penalized 3D PET Image Reconstruction
Open Access
- 31 August 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 42 (1) , 29-41
Abstract
Penalised PET image reconstruction algorithms are often accelerated during early iterations with the use of subsets. However, these methods may exhibit limit cycle behaviour at later iterations due to variations between subsets. Desirable converged images can be achieved for a subclass of these algorithms via the implementation of a relaxed step size sequence, but the heuristic selection of parameters will impact the quality of the image sequence and algorithm convergence rates. In this work, we demonstrate the adaption and application of a class of stochastic variance reduction gradient algorithms for PET image reconstruction using the relative difference penalty and numerically compare convergence performance to BSREM. The two investigated algorithms are: SAGA and SVRG. These algorithms require the retention in memory of recently computed subset gradients, which are utilised in subsequent updates. We present several numerical studies based on Monte Carlo simulated data and a patient data set for fully 3D PET acquisitions. The impact of the number of subsets, different preconditioners and step size methods on the convergence of regions of interest values within the reconstructed images is explored. We observe that when using constant preconditioning, SAGA and SVRG demonstrate reduced variations in voxel values between subsequent updates and are less reliant on step size hyper-parameter selection than BSREM reconstructions. Furthermore, SAGA and SVRG can converge significantly faster to the penalised maximum likelihood solution than BSREM, particularly in low count data.Keywords
All Related Versions
Funding Information
- General Electric (GE) Healthcare
- National Institute for Health and Care Research (NIHR) University College London Hospital (UCLH) Biomedical Research Centre
- Engineering and Physical Sciences Research Council (EPSRC) Centre for Doctoral Training i4Health (EP/S021930/1)
- EPSRC project (EP/T000864/1)
- CCP SyneRBI through EPSRC (EP/T026693/1)
This publication has 45 references indexed in Scilit:
- Acceleration of motion-compensated PET reconstruction: ordered subsets-gates EM algorithms anda priorireference gate informationPhysics in Medicine & Biology, 2011
- GATE V6: a major enhancement of the GATE simulation platform enabling modelling of CT and radiotherapyPhysics in Medicine & Biology, 2011
- Globally convergent image reconstruction for emission tomography using relaxed ordered subsets algorithmsIEEE Transactions on Medical Imaging, 2003
- One-pass list-mode EM algorithm for high-resolution 3-D PET image reconstruction into large arraysIEEE Transactions on Nuclear Science, 2002
- A concave prior penalizing relative differences for maximum-a-posteriori reconstruction in emission tomographyIEEE Transactions on Nuclear Science, 2002
- Fast EM-like methods for maximum "a posteriori" estimates in emission tomographyIEEE Transactions on Medical Imaging, 2001
- A row-action alternative to the EM algorithm for maximizing likelihood in emission tomographyIEEE Transactions on Medical Imaging, 1996
- Accelerated image reconstruction using ordered subsets of projection dataIEEE Transactions on Medical Imaging, 1994
- Algebraic reconstruction techniques can be made computationally efficient (positron emission tomography application)IEEE Transactions on Medical Imaging, 1993
- Birthday paradox, coupon collectors, caching algorithms and self-organizing searchDiscrete Applied Mathematics, 1992