Long-term stability and performance characteristics of crystal quartz gauge at high pressures and temperatures
Authors:
- Y. SudoYSY. Sudo
- B.K. SinhaBSB.K. Sinha
- M. NiwaMNM. Niwa
- 1 March 2000
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 47 (2) , 346-354
Abstract
Good long-term stability of high precision quartz pressure sensors is necessary for various applications ranging from pressure transient analysis to permanent monitoring systems for optimal reservoir management in the petroleum industry. A crystal quartz gauge (CQG/sup 1/) is a dual-mode, thickness-shear, quartz pressure sensor that has been used in oil field services for the past 8 years. High accuracy, resolution, and fast response time of this sensor enable a reliable estimate of formation permeability and oil/water interfaces in reservoirs that help reduce the overall cost of oil and gas production. The sensing resonator characteristics can be described in terms of equivalent circuit parameters (motional resistance and capacitance), resonator-Q and the short-term frequency stability of both the B- and C-modes of vibrations at various temperatures. The pressure reading errors of manufactured gauges are less than 8.89 kPa (1 psi) (plus 0.01% of the reading because of the uncertainty of the dead-weight tester). The pressure resolution is better than 20.7 Pa (0.003 psi) over a 1-s gate time. An extremely effective dynamic compensation algorithm yields corrected pressure readings with a very fast response time as short as a strain-gauge-based pressure transducer while retaining the high performance of a quartz gauge. Recent long-term stability tests of CBGs show a negligibly small drift of the order of a few tenths of 1 psi (0.1 psi=689 Pa) at 103 MPa (15 kpsi) and 175/spl deg/C for a period of more than 1 yr. These results confirm that the CQG characteristics exceed the demanding specifications for both the well tests and permanent monitoring systems.Keywords
This publication has 15 references indexed in Scilit:
- A dual-mode thickness-shear quartz pressure sensorIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1993
- Experimental verification of stress compensation in the SBTC-cutIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1989
- A Reduced Hysteresis, Extended Range Quartz Pressure Transducer1987
- Jumps in Frequency Temperature Response of Contoured Resonators: An Analysis Performed with a Perturbation Model and X-Ray Patterns1984
- Elastic waves in crystals under a biasFerroelectrics, 1982
- Stress Compensated Orientations for Thickness-Shear Quartz Resonators1981
- Stress Induced Frequency Shifts in Thickness-Mode Quartz Resonators1980
- Perturbation theory for linear electroelastic equations for small fields superposed on a biasThe Journal of the Acoustical Society of America, 1978
- Static and Dynamic Frequency-Temperature Behavior of Singly and Doubly Rotated, Oven-Controlled Quartz Resonators1978