Breakage and retention of thoracic paravertebral catheter: a case report
Open Access
- 5 January 2017
- journal article
- case report
- Published by Springer Nature in JA Clinical Reports
- Vol. 3 (1) , 4
Abstract
Paravertebral catheters are generally inserted and removed without complications. However, catheter breakage occurs rarely. This is the first report describing breakage of a thoracic paravertebral catheter and retention of the catheter fragment within the patient. A 65-year-old female patient complained of an unusual sensation in her back during postoperative chemotherapy for lung cancer. A catheter fragment was identified in the soft tissues of the back on computed tomography. The paravertebral catheter had been placed 2 years prior left lower lobectomy. The patient had neither neurological symptoms nor infection signs around the fragment. However, the potential side effects of chemotherapy, including coagulopathy and immunosuppression, increased the risk of late-onset hematoma and abscess formation around the fragment. Therefore, we surgically removed the catheter fragment. Analysis of the fragment revealed that the catheter had been severed by the cutting edge of the Tuohy needle or the suture needle. In this report, a paravertebral catheter fragment was retained in the posterior mediastinum for 2 years. The catheter was likely damaged during the insertion procedure. We suggest that catheters should not be withdrawn through the Tuohy needle, but be withdrawn together with the Tuohy needle. Although secure fixation of the catheter can be achieved with sutures, to reduce the risk of damage to the catheter, alternative methods, such as surgical tapes or skin glue should be considered. After removal of a catheter, its tip should be checked to ensure that the entire catheter has been completely removed. If a catheter fragment is retained within the patient, removal of the fragment should be considered according to the patient’s condition and risks.Keywords
This publication has 8 references indexed in Scilit:
- Delayed Onset of Subdural Hematoma following Epidural Catheter BreakageGlobal Spine Journal, 2015
- Ultrasound-guided thoracic paravertebral puncture and placement of catheters in human cadavers: where do catheters go?British Journal of Anaesthesia, 2010
- Cochrane Database of Systematic ReviewsCochrane Database of Systematic Reviews, 2007
- Subcutaneous effusion resulting from an epidural catheter fragmentBritish Journal of Anaesthesia, 2006
- Breakage of Epidural Catheters: A Comparison of an Arrow Reinforced Catheter and Other Nonreinforced CathetersAnesthesia & Analgesia, 2001
- Epidural catheter breakage: a possible mechanismInternational Journal of Obstetric Anesthesia, 2000
- Radicular Pain Due to a Retained Fragment of Epidural CatheterAnesthesiology, 1997
- Lumbar Stenosis Complicating Retained Epidural Catheter TipAnesthesiology, 1995