Comparative Analysis of the Efficacy of Continuous Glucose Monitoring and Self-Monitoring of Blood Glucose in Type 1 Diabetes Mellitus
Open Access
- 1 September 2012
- journal article
- research article
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 6 (5) , 1094-1102
Abstract
Self-monitoring of blood glucose (SMBG) and continuous glucose monitoring (CGM) have been proven effective in improving hemoglobin A1c (HbA1c) and in reducing hypoglycemia in patients with type 1 diabetes mellitus (T1DM). It is not clear, however, if CGM provides further efficacy and safety benefits beyond SMBG in the management of T1DM. MEDLINE (1966-November 2009), COCHRANE REGISTRY (all years), and EMBASE (1980-November 2009), and article bibliographies were searched for randomized controlled trials (RCTs) investigating the use of CGM in patients with T1DM, with clinical outcomes, including HbA1c and hypoglycemia and/or hyperglycemia. Fourteen RCTs met eligibility criteria [n = 1188 patients, 97.4% with T1DM, age 29.0 ± 14.3 years, diabetes duration 11.7 ± 7.0 years, and baseline HbA1c 8.3 ± 0.8% (mean ± standard deviation)]. Compared with SMBG, the use of CGM was associated with a greater reduction in HbA1c [−0.3% (confidence interval: 0.4, −0.2), p < .0001]. The number of hypoglycemic events was not significantly different between the CGM and SMBG groups (0.52 ± 0.52 versus 0.52 ± 0.63 events/day, p = .5), but duration of hypoglycemia was shorter for the CGM group (75 ± 39 versus 89 ± 19 min/day), with an incremental reduction of hypoglycemia duration of −15.2 min/day, p < .0001. Continuous glucose monitoring also resulted in a shorter duration of hyperglycemia than SMBG (172 ± 125 versus 217 ± 152 min/day, p = .04). The use of CGM is associated with improvement in metabolic control in T1DM, with significant short- and long-term reductions in HbA1c and reduction in the duration of periods of hypoglycemia and hyperglycemia versus SMBG.Keywords
This publication has 42 references indexed in Scilit:
- Incremental Value of Continuous Glucose Monitoring When Starting Pump Therapy in Patients With Poorly Controlled Type 1 DiabetesDiabetes Care, 2009
- Multicentre, randomised, controlled study of the impact of continuous sub-cutaneous glucose monitoring (GlucoDay®) on glycaemic control in type 1 and type 2 diabetes patientsDiabetes & Metabolism, 2009
- The Effect of Continuous Glucose Monitoring in Well-Controlled Type 1 DiabetesDiabetes Care, 2009
- Standards of Medical Care in Diabetes—2009Diabetes Care, 2009
- The Effect of Intensive Glycemic Treatment on Coronary Artery Calcification in Type 1 Diabetic Participants of the Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) StudyDiabetes, 2006
- Real-Time Continuous Glucose Monitoring in Pediatric Patients During and After Cardiac SurgeryPediatrics, 2006
- Use of the Continuous Glucose Monitoring System to Guide Therapy in Patients With Insulin-Treated Diabetes: A Randomized Controlled TrialMayo Clinic Proceedings, 2004
- Continuous Subcutaneous Glucose Monitoring in Children With Type 1 DiabetesPediatrics, 2001
- Assessing the quality of reports of randomized clinical trials: Is blinding necessary?Controlled Clinical Trials, 1996
- Meta-analysis in clinical trialsControlled Clinical Trials, 1986