Abstract
OBJECTIVE To compare the improvements in glycemic control associated with transitioning to insulin pump therapy in patients using continuous glucose monitoring versus standard blood glucose self-monitoring. RESEARCH DESIGN AND METHODS The RealTrend study was a 6-month, randomized, parallel-group, two-arm, open-label study of 132 adults and children with uncontrolled type 1 diabetes (A1C ≥8%) being treated with multiple daily injections. One group was fitted with the Medtronic MiniMed Paradigm REAL-Time system (PRT group), an insulin pump with integrated continuous subcutaneous glucose monitoring (CGM) capability, with instructions to wear CGM sensors at least 70% of the time. Conventional insulin pump therapy was initiated in the other group (continuous subcutaneous insulin infusion [CSII] group). Outcome measures included A1C and glycemic variability. RESULTS A total of 115 patients completed the study. Between baseline and trial end, A1C improved significantly in both groups (PRT group −0.81 ± 1.09%, P < 0.001; CSII group −0.57 ± 0.94%, P < 0.001), with no significant difference between groups. When the 91 patients who were fully protocol-compliant (including CGM sensor wear ≥70% of the time) were considered, A1C improvement was significantly greater in the PRT group (P = 0.004) (PRT group −0.96 ± 0.93%, P < 0.001; CSII group −0.55 ± 0.93%, P < 0.001). Hyperglycemia parameters decreased in line with improvements in A1C with no impact on hypoglycemia. CONCLUSIONS CGM-enabled insulin pump therapy improves glycemia more than conventional pump therapy during the first 6 months of pump use in patients who wear CGM sensors at least 70% of the time.Keywords
This publication has 20 references indexed in Scilit:
- Standards of Medical Care in Diabetes—2009Diabetes Care, 2009
- Continuous Glucose Monitoring and Intensive Treatment of Type 1 DiabetesNew England Journal of Medicine, 2008
- Severe hypoglycaemia and glycaemic control in Type 1 diabetes: meta‐analysis of multiple daily insulin injections compared with continuous subcutaneous insulin infusionDiabetic Medicine, 2008
- In Type 1 diabetic patients with good glycaemic control, blood glucose variability is lower during continuous subcutaneous insulin infusion than during multiple daily injections with insulin glargineDiabetic Medicine, 2008
- The transition to young adulthood in youth with type 1 diabetes on intensive treatmentPediatric Diabetes, 2007
- Improved Glycemic Control in Poorly Controlled Patients with Type 1 Diabetes Using Real-Time Continuous Glucose MonitoringDiabetes Care, 2006
- Is the Frequency of Self-Monitoring of Blood Glucose Related to Long-Term Metabolic Control? Multicenter Analysis Including 24 500 Patients from 191 Centers in Germany and AustriaExperimental and Clinical Endocrinology & Diabetes, 2006
- A Randomized, Prospective Trial Comparing the Efficacy of Continuous Subcutaneous Insulin Infusion With Multiple Daily Injections Using Insulin GlargineDiabetes Care, 2004
- Family conflict, adherence, and glycaemic control in youth with short duration Type 1 diabetesDiabetic Medicine, 2002
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusNew England Journal of Medicine, 1993