Cardiac CT assessment of tissue thickness at the ostium of the left atrial appendage predicts acute success of radiofrequency ablation
Open Access
- 23 October 2017
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 40 (11) , 1218-1226
Abstract
Background: Tissue thickness at the site of ablation is a determinant of lesion transmurality. We reported the feasibility, safety, and efficacy of longstanding persistent atrial fibrillation ablation, incorporating deliberate left atrial appendage (LAA) isolation and occlusion, and identified systematic differences in ostial LAA tissue thickness in a matched cohort of cadaveric specimens.Methods: Preprocedural cardiac computed tomography (CCT) scans were acquired from 22 patients undergoing LAA isolation and subsequent occlusion. Using a novel CCT wall thickness algorithm, LAA ostial wall thickness was assessed in vivo, compared with measurements from the cadaveric specimens, and analyzed for differences between regions that demonstrated acute electrical reconnection and those that did not.Results: Mean tissue thickness calculated for each LAA ostial quadrant was 2.1 (±0.6) mm (anterior quadrant), 1.9 (±0.4) mm (superior quadrant), 1.5 (±0.4) mm (posterior quadrant), and 1.8 (±0.7) mm (inferior quadrant). Tissue was significantly thicker in the anterior (P = 0.004) and superior quadrants (P = 0.014) than the posterior quadrant. Higher thickness measurements were recorded from quadrants demonstrated to be thicker from histology. Tissue was significantly thicker in regions that demonstrated acute electrical reconnection (1.9 (±0.6) mm) when compared with those that did not (1.6 (±0.5) mm) (P = 0.008).Conclusions: CCT imaging may be used to detect differences in wall thickness at different atrial locations and success of LAA ablation may be affected by local tissue thickness. Atrial wall thickness may need to be considered as a metric to guide titration of radiofrequency energy for safe and successful ablation.Keywords
Funding Information
- Guy's and St Thomas' NHS Foundation Trust
- National Institute of General Medical Sciences
- National Institutes of Health (P41 GM103545-18)
- Boston Scientific Corporation
- Medical Research Council (MR/N001877/1)
This publication has 15 references indexed in Scilit:
- Low contact force and force-time integral predict early recovery and dormant conduction revealed by adenosine after pulmonary vein isolationEP Europace, 2015
- Left atrial appendage electrical isolation and concomitant device occlusion: A safety and feasibility study with histologic characterizationHeart Rhythm, 2015
- Relationship Between Catheter Contact Force and Radiofrequency Lesion Size and Incidence of Steam Pop in the Beating Canine HeartCirculation: Arrhythmia and Electrophysiology, 2014
- Contact force and force-time integral in atrial radiofrequency ablation predict transmurality of lesionsEP Europace, 2014
- 2012 focused update of the ESC Guidelines for the management of atrial fibrillationEuropean Heart Journal, 2012
- Left atrial thickness under the catheter ablation lines in patients with paroxysmal atrial fibrillation: insights from 64-slice multidetector computed tomographyHeart and Vessels, 2012
- 2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for Patient Selection, Procedural Techniques, Patient Management and Follow-up, Definitions, Endpoints, and Research Trial DesignA report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. Developed in partnership with the European Heart Rhythm Association (EHRA), a registered branch of the European Society of Cardiology (ESC) and the European Cardiac Arrhythmia Society (ECAS); and in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), the Asia Pacific Heart Rhythm Society (APHRS), and the Society of Thoracic Surgeons (STS). Endorsed by the governing bodies of the American College of Cardiology Foundation, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, the Asia Pacific Heart Rhythm Society, and the Heart Rhythm SocietyEP Europace, 2012
- Cardiac CT: How much can temporal resolution, spatial resolution, and volume coverage be improved?Journal of Cardiovascular Computed Tomography, 2009
- Aging Dilates Atrium and Pulmonary VeinsChest, 2008
- Anatomic Relations Between the Esophagus and Left Atrium and Relevance for Ablation of Atrial FibrillationCirculation, 2005