Collection Efficiencies of High Flow Rate Personal Respirable Samplers When Measuring Arizona Road Dust and Analysis of Quartz by X-ray Diffraction
Authors:
Open Access
- 27 January 2014
- journal article
- research article
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 58 (4) , 512-523
Abstract
Prolonged exposure to respirable crystalline silica (RCS) causes silicosis and is also considered a cause of cancer. To meet emerging needs for precise measurements of RCS, from shorter sampling periods (−1 and with flow rates proposed by the National Institute for Occupational Safety and Health of 11.2 and 4.4 l · min−1. Samplers were exposed to aerosols of ultrafine and medium grades of Arizona road dust (ARD) generated in a calm air chamber. All analyses for RCS in this study were performed at the Health and Safety Laboratory. The difference in flow rates for the GK2.69 is small and does not result in a substantial difference in collection efficiency for the dusts tested, while the performance of the FSP10 at 11.2 l · min−1 was more comparable with samples from the SIMPEDS. Conversely, the GK2.69 collected proportionately more crystalline silica in the respirable dust than other samplers, which then produced RCS results most comparable with the SIMPEDS. The CIP 10 R collected less ultrafine ARD than other samplers, as might be expected based on earlier performance evaluations. The higher flow rate for the FSP10 should be an added advantage for task-specific sampling or when measuring air concentrations less than current occupational exposure limits.Keywords
This publication has 8 references indexed in Scilit:
- Quartz Measurement in Coal Dust with High-Flow Rate Samplers: Laboratory StudyAnnals of Occupational Hygiene, 2011
- Performance of High Flow Rate Samplers for Respirable Particle CollectionAnnals of Occupational Hygiene, 2010
- Comparison of Portable, Real-Time Dust Monitors Sampling Actively, with Size-Selective Adaptors, and PassivelyAnnals of Occupational Hygiene, 2007
- Analytical Performance CriteriaJournal of Occupational and Environmental Hygiene, 2007
- Study of fifteen respirable aerosol samplers used in occupational hygieneAnnals of Occupational Hygiene, 2001
- Study of fifteen respirable aerosol samplers used in occupational hygieneAnnals of Occupational Hygiene, 2001
- Performance assessment of three personal cyclone models, using an Aerodynamic Particle SizerJournal of Aerosol Science, 1995
- A HIGHER-FLOW RATE CYCLONE FOR DETERMINATION OF RESPIRABLE DUSTAnnals of Occupational Hygiene, 1987