Performance of High Flow Rate Samplers for Respirable Particle Collection
Open Access
- 21 July 2010
- journal article
- research article
- Published by Oxford University Press (OUP) in Annals of Occupational Hygiene
- Vol. 54 (6) , 697-709
Abstract
The American Conference of Governmental Industrial hygienists (ACGIH) lowered the threshold limit value (TLV) for respirable crystalline silica (RCS) exposure from 0.05 to 0.025 mg m−3 in 2006. For a working environment with an airborne dust concentration near this lowered TLV, the sample collected with current standard respirable aerosol samplers might not provide enough RCS for quantitative analysis. Adopting high flow rate sampling devices for respirable dust containing silica may provide a sufficient amount of RCS to be above the limit of quantification even for samples collected for less than full shift. The performances of three high flow rate respirable samplers (CIP10-R, GK2.69, and FSP10) have been evaluated in this study. Eleven different sizes of monodisperse aerosols of ammonium fluorescein were generated with a vibrating orifice aerosol generator in a calm air chamber in order to determine the sampling efficiency of each sampler. Aluminum oxide particles generated by a fluidized bed aerosol generator were used to test (i) the uniformity of a modified calm air chamber, (ii) the effect of loading on the sampling efficiency, and (iii) the performance of dust collection compared to lower flow rate cyclones in common use in the USA (10-mm nylon and Higgins–Dewell cyclones). The coefficient of variation for eight simultaneous samples in the modified calm air chamber ranged from 1.9 to 6.1% for triplicate measures of three different aerosols. The 50% cutoff size (50dae) of the high flow rate samplers operated at the flow rates recommended by manufacturers were determined as 4.7, 4.1, and 4.8 μm for CIP10-R, GK2.69, and FSP10, respectively. The mass concentration ratio of the high flow rate samplers to the low flow rate cyclones decreased with decreasing mass median aerodynamic diameter (MMAD) and high flow rate samplers collected more dust than low flow rate samplers by a range of 2–11 times based on gravimetric analysis. Dust loading inside the high flow rate samplers does not appear to affect the particle separation in either FSP10 or GK2.69. The high flow rate samplers overestimated compared to the International Standards Organization/Comité Européen de Normalisation/ACGIH respirable convention [up to 40% at large MMAD (27.5 μm)] and could provide overestimated exposure data with the current flow rates. However, both cyclones appeared to be able to provide relatively unbiased assessments of RCS when their flow rates were adjusted.Keywords
This publication has 31 references indexed in Scilit:
- Size Distributions of 0.5 to 20 μm Aerodynamic Diameter Lead-Containing Particles from Aerosol Sampler Walls and FiltersAerosol Science and Technology, 2009
- Reducing Silica and Dust Exposures in Construction During Use of Powered Concrete-Cutting Hand Tools: Efficacy of Local Exhaust Ventilation on Hammer DrillsJournal of Occupational and Environmental Hygiene, 2008
- Study of fifteen respirable aerosol samplers used in occupational hygieneAnnals of Occupational Hygiene, 2001
- Study of fifteen respirable aerosol samplers used in occupational hygieneAnnals of Occupational Hygiene, 2001
- Shift of Aerosol Penetration in Respirable Cyclone SamplersAIHA Journal, 1999
- Proficiency Analytical Testing (PAT) Silica Variability, 1990–1998AIHA Journal, 1999
- The performance evaluation of aerosol samplers tested with monodisperse aerosolsJournal of Aerosol Science, 1995
- Laboratory Evaluation of the CIP 10 Personal Dust SamplerAIHA Journal, 1988
- Generation of Large, Solid, Monodisperse Calibration AerosolsAerosol Science and Technology, 1988
- A HIGHER-FLOW RATE CYCLONE FOR DETERMINATION OF RESPIRABLE DUSTAnnals of Occupational Hygiene, 1987