A modified approach to actively remove high viscosity silicone oil through 23-gauge cannula
Authors:
Open Access
- 18 September 2016
- journal article
- Published by Press of International Journal of Ophthalmology (IJO Press) in International Journal of Ophthalmology
- Vol. 9 (9) , 1294-1298
Abstract
To report a simple approach to actively remove high viscosity silicone oil through a 23-gauge cannula via pars plana. Forty-eight eyes of 48 patients underwent silicone oil (5700 centistokes) removal (SOR) were enrolled. A section of blood transfusion set was prepared to connect a standard 23-gauge cannula and vitrectomy machine. Silicone oil was removed with suction of 500-mm Hg vacuum through the cannula. Main outcome measures were SOR duration, number of sutured sites, intraocular pressure (IOP), best-corrected visual acuity (BCVA), and complications. Silicone oil was successfully removed in all cases. The mean SOR time was 5.70±0.85min. Nine eyes (18.75%) needed suture partial sclerotomies. No intraoperative complications were noted. Transient hypotony (≤8 mm Hg) was seen in 3 eyes (6.25%) on postoperative day 1, but all resolved within 1wk. Retinal reattachment was achieved in all cases and no other postoperative complications were noted during 3-month following-up. BCVA at the final visit improved or stabilized in all patients comparing to the preoperative level. Active removal of high viscosity silicone oil through a 23-gauge instrument cannula jointed with blood transfusion set is a practical and reliable technique when considering two sides of efficacy and safety.Keywords
This publication has 19 references indexed in Scilit:
- A machine-independent method to have active removal of 5,000 centistokes silicone oil using plastic infusion tube and 23-gauge microcannulas.BMC Ophthalmology, 2015
- Surveillance d’un tamponnement par huile de siliconeJournal Français d'Ophtalmologie, 2014
- A Novel Technique for High-Density Silicone Oil RemovalRetina, 2012
- ACTIVE SILICONE OIL REMOVAL WITH A MODIFIED VACUUM SYRINGERETINAL Cases & Brief Reports, 2012
- A New Approach for Active Removal of 5,000 Centistokes Silicone Oil Through 23-Gauge CannulaRetina, 2010
- EFFECTS OF PERFLUOROCARBON LIQUIDS AND SILICONE OIL ON HUMAN RETINAL PIGMENT EPITHELIAL CELLS AND RETINAL GANGLION CELLSRetina, 2009
- Removal of Densiron-68 with a 23-gauge transconjunctival vitrectomy systemEye, 2009
- Short-term Outcomes of 23-gauge Pars Plana VitrectomyAmerican Journal of Ophthalmology, 2008
- Active Removal of Silicone Oil With 25-Gauge Sutureless SystemRetina, 2007
- TRANSCONJUNCTIVAL SUTURELESS 23-GAUGE VITRECTOMYRetina, 2005