Parameters affecting anterior capsulotomy tear strength and distension
- 1 March 2019
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 45 (3) , 355-360
Abstract
Purpose To study the effects of anterior capsulotomy diameter and discontinuity on tear threshold load and distension for the technique of continuous curvilinear capsulorhexis (CCC). Setting Singapore National Eye Centre, Singapore, and CapsuLaser Inc., Livermore, California, USA. Design Two separate randomized pairwise cadaver eye preclinical studies. Methods Capsulotomies were performed in 40 cadaver eyes of 20 donors using CCC. The pairwise comparisons were divided into 2 study groups: Study A: Continuous versus discontinuous capsulotomies; Study B: Capsulotomy diameter of 5.0 mm and smaller versus diameters of 5.2 mm and larger. A shoe-tree method was used to apply load to the capsulotomy rim, and the Instron tensile stress instrument measured threshold load and distension to initiate a capsular tear. Wilcoxon matched-pairs signed-rank tests were performed to assess statistical superiority. Results In Study Group A, all pairs demonstrated that continuous capsulotomies were better than discontinuous capsulotomies for both the anterior tear threshold load and distension (P < .01). In Study Group B, 80% of the pairs demonstrated that diameters of 5.2 mm and larger were better than those of 5.0 mm and smaller diameter (P < .05). Conclusions Anterior capsulotomies behave as nonlinear elastic (elastomeric) systems when exposed to an external load and distension. This study demonstrated that continuous circular capsulotomies were more resistant to anterior tears than discontinuous capsulotomies. A point of irregularity or a defect in a capsulotomy rim has a high probability of being the tear initiation point. Furthermore, larger diameter capsulotomies were more resistant to anterior tears than smaller capsulotomies.Keywords
This publication has 24 references indexed in Scilit:
- Efficacy and Safety of Femtosecond Laser-Assisted Cataract Surgery Compared with Manual Cataract SurgeryOphthalmology, 2016
- Comparison of Manual, Femtosecond Laser, and Precision Pulse Capsulotomy Edge Tear Strength in Paired Human Cadaver EyesOphthalmology, 2016
- Femtosecond laser–assisted cataract surgery versus standard phacoemulsification cataract surgery: Outcomes and safety in more than 4000 cases at a single centerJournal of Cataract & Refractive Surgery, 2015
- Femtosecond laser: The future of cataract surgery?Journal of Cataract & Refractive Surgery, 2011
- Initial Clinical Evaluation of an Intraocular Femtosecond Laser in Cataract SurgeryJournal of Refractive Surgery, 2009
- Phacoemulsification with topical anesthesia: Resident experienceJournal of Cataract & Refractive Surgery, 2006
- Intraoperative complications of 1000 phacoemulsification procedures: A prospective studyJournal of Cataract & Refractive Surgery, 1998
- Development, advantages, and methods of the continuous circular capsulorhexis techniqueJournal of Cataract & Refractive Surgery, 1990
- Theorie und Operationstechnik der KapsulorhexisKlinische Monatsblätter für Augenheilkunde, 1987
- On a new method to cure cataract by extraction of the lens.British Journal of Ophthalmology, 1967