Sheraz M. Daya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sheraz M. Daya has a total of 138 co-authors. Here are the top co-authors by number of shared publications:
- Alessandra Di Maria
Department of Ophthalmology, IRCCS Humanitas Research Hospital, Milan, Italy
2 shared publications Camille Bosc
Clinique Jules Verne, Nantes, France
2 shared publicationsChristophe Chassain
Clinique Beau Soleil, Montpellier, France
2 shared publicationsDavid Shahnazaryan
Centre for Sight, London, UK
2 shared publications- Edward J. Holland
Cincinnati Eye Institute, University of Cincinnati, Cincinnati, Ohio, USA
2 shared publications - Erik Mertens
Medipolis, Antwerp, Belgium
2 shared publications
Latest Publications
- Open Access
- 1 August 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-11
Clinical Performance of an Isofocal Toric Intraocular Lens with Double C-Loop Haptics: A Multicenter Retrospective Study
Purpose: To evaluate clinical outcomes in eyes with pre-existing astigmatism undergoing cataract surgery or refractive lens exchange with the implantation of an isofocal optic-design toric intraocular lens (IOL) with double C-loop haptics. Method: This multicenter retrospective study comprised 100 eyes (65 patients) implanted with the Isopure Serenity toric IOL (BVI, Inc.) conducted across four sites. Postoperative evaluation at between 2 and 3 months included manifest refraction, monocular uncorrected and distance corrected visual acuity (UDVA and CDVA), monocular uncorrected and distance corrected intermediate visual acuity (UIVA and DCIVA, at 80 and 66 cm), monocular uncorrected and distance corrected near visual acuity (UNVA and DCNVA, at 40 cm), binocular defocus curve and rotational stability. Results: Manifest refraction spherical equivalent and refractive astigmatism were − 0.24± 0.41D and − 0.36± 0.36D, respectively. About 79% and 97% of eyes were within ± 0.50D and ± 1.00D, respectively, and 80% and 96% of eyes were ≤ 0.50D and ≤ 1.00D of refractive cylinder, respectively. At distance vision, the mean monocular CDVA was − 0.02± 0.06 logMAR and 92.93% of eyes showed a CDVA of ≥ 20/20. At intermediate vision, the mean monocular DCIVA values were 0.10± 0.07 and 0.17± 0.10 logMAR at 80 cm and 66 cm, respectively; and 96.92% and 88.33% of eyes showed a DCIVA of ≥ 20/32 at 80 cm and 66 cm, respectively. At near vision, the mean monocular DCNVA was 0.31± 0.08 logMAR and 75.44% of eyes showed a DCNVA of ≥ 20/40. The binocular depth of focus range was approximately 1.50D. The mean absolute IOL rotation was 2.73± 2.58 degrees with all eyes having a rotation of < 10 degrees. Conclusions: Eyes with pre-existing astigmatism implanted with the Isopure Serenity toric IOL showed good distance visual acuity and functional intermediate vision, with high refractive accuracy and good rotational stability following cataract and refractive lens exchange surgery.
- 1 August 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-11
Open AccessClinical Performance of an Isofocal Toric Intraocular Lens with Double C-Loop Haptics: A Multicenter Retrospective Study
Purpose: To evaluate clinical outcomes in eyes with pre-existing astigmatism undergoing cataract surgery or refractive lens exchange with the implantation of an isofocal optic-design toric intraocular lens (IOL) with double C-loop haptics. Method: This multicenter retrospective study comprised 100 eyes (65 patients) implanted with the Isopure Serenity toric IOL (BVI, Inc.) conducted across four sites. Postoperative evaluation at between 2 and 3 months included manifest refraction, monocular uncorrected and distance corrected visual acuity (UDVA and CDVA), monocular uncorrected and distance corrected intermediate visual acuity (UIVA and DCIVA, at 80 and 66 cm), monocular uncorrected and distance corrected near visual acuity (UNVA and DCNVA, at 40 cm), binocular defocus curve and rotational stability. Results: Manifest refraction spherical equivalent and refractive astigmatism were − 0.24± 0.41D and − 0.36± 0.36D, respectively. About 79% and 97% of eyes were within ± 0.50D and ± 1.00D, respectively, and 80% and 96% of eyes were ≤ 0.50D and ≤ 1.00D of refractive cylinder, respectively. At distance vision, the mean monocular CDVA was − 0.02± 0.06 logMAR and 92.93% of eyes showed a CDVA of ≥ 20/20. At intermediate vision, the mean monocular DCIVA values were 0.10± 0.07 and 0.17± 0.10 logMAR at 80 cm and 66 cm, respectively; and 96.92% and 88.33% of eyes showed a DCIVA of ≥ 20/32 at 80 cm and 66 cm, respectively. At near vision, the mean monocular DCNVA was 0.31± 0.08 logMAR and 75.44% of eyes showed a DCNVA of ≥ 20/40. The binocular depth of focus range was approximately 1.50D. The mean absolute IOL rotation was 2.73± 2.58 degrees with all eyes having a rotation of < 10 degrees. Conclusions: Eyes with pre-existing astigmatism implanted with the Isopure Serenity toric IOL showed good distance visual acuity and functional intermediate vision, with high refractive accuracy and good rotational stability following cataract and refractive lens exchange surgery.
- Open Access
- 24 May 2026
- Published by Knowledge E DMCC in Journal of Ophthalmic and Vision Research
- Vol. 21, 1-15
Anterior Segment Eye Diseases and Quality of Life: An Updated Comprehensive Narrative Review
Anterior segment eye diseases significantly affect patients’ quality of life (QoL) by impairing physical health, psychological well-being, social interactions, and economic stability. Conditions such as dry eye disease, blepharitis, conjunctivitis, keratoconus, keratitis, and corneal dystrophies cause chronic discomfort, visual disturbance, and emotional distress, leading to reduced daily functioning and work productivity. Other disorders like chalazion, trichiasis, ptosis, strabismus, and thyroid eye disease entail a psychological burden by affecting appearance and social confidence. This narrative review comprehensively examines the multidimensional impact of anterior segment diseases on QoL. A systematic literature search was conducted in PubMed, Scopus, Web of Science, and Google Scholar for English-language articles published between December 1997 and February 2025. Using relevant keywords and Boolean operators, we initially identified 854 articles. Following duplicate removal and screening based on inclusion and exclusion criteria focused on QoL-related outcomes in anterior segment diseases, we selected 72 high-quality studies for the review. This methodology ensured a thorough and focused analysis of the available evidence. Findings highlight the importance of addressing both clinical symptoms and psychosocial effects in management strategies. Future research should emphasize interventions that improve ocular function alongside overall well-being.
- 24 May 2026
- Published by Knowledge E DMCC in Journal of Ophthalmic and Vision Research
- Vol. 21, 1-15
Open AccessAnterior Segment Eye Diseases and Quality of Life: An Updated Comprehensive Narrative Review
Anterior segment eye diseases significantly affect patients’ quality of life (QoL) by impairing physical health, psychological well-being, social interactions, and economic stability. Conditions such as dry eye disease, blepharitis, conjunctivitis, keratoconus, keratitis, and corneal dystrophies cause chronic discomfort, visual disturbance, and emotional distress, leading to reduced daily functioning and work productivity. Other disorders like chalazion, trichiasis, ptosis, strabismus, and thyroid eye disease entail a psychological burden by affecting appearance and social confidence. This narrative review comprehensively examines the multidimensional impact of anterior segment diseases on QoL. A systematic literature search was conducted in PubMed, Scopus, Web of Science, and Google Scholar for English-language articles published between December 1997 and February 2025. Using relevant keywords and Boolean operators, we initially identified 854 articles. Following duplicate removal and screening based on inclusion and exclusion criteria focused on QoL-related outcomes in anterior segment diseases, we selected 72 high-quality studies for the review. This methodology ensured a thorough and focused analysis of the available evidence. Findings highlight the importance of addressing both clinical symptoms and psychosocial effects in management strategies. Future research should emphasize interventions that improve ocular function alongside overall well-being.
- Open Access
- 1 September 2025
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 3121-3131
Clinical Outcomes of a Multicenter Study Following Implantation of an Isofocal Optic IOL with Double C-Loop Haptics
Purpose: To report clinical outcomes in patients implanted with an isofocal optic-design intraocular lens (IOL) with double C-loop haptics following cataract surgery. Methods: This was a multicentre-prospective-study involving 108 eyes (54 subjects) implanted with the Isopure Serenity (BVI, Inc). IOL. At least 3 months after the surgery, the following parameters were analysed: refraction, monocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA) and distance corrected-intermediate visual acuity (DCIVA) both at 80 and 66 cm, uncorrected near visual acuity (UNVA), and distance corrected near visual acuity (DCNVA) at 40 cm. In addition, the binocular defocus curve was measured. Results: 79.63% and 98.15% of eyes were within ± 0.50D and ± 1.00D of the target spherical equivalent, respectively. 68.41% and 98.15% of eyes had a UDVA and CDVA of 20/20 or better, respectively, with 88.89% and 99.07% achieving 20/25 or better, respectively (the mean values for UDVA and CDVA were 0.02± 0.11 and – 0.04± 0.05 logMAR, respectively). 77.14% and 39.39% of eyes achieved a DCIVA of 20/32 or better at 80 cm and 66 cm, respectively, and 90% and 72.73% achieved a DCIVA of 20/40 or better at 80 and 66 cm, respectively (the mean values for DCIVA were 0.19± 0.10 and 0.28± 0.11 logMAR, 80 cm and at 66 cm, respectively). 25% and 15.15% of eyes had a UNVA and DCNVA of 20/32 or better, respectively, with 39.81% and 31.82% achieving a UNVA and DCNVA of 20/40 or better, respectively (mean values for UNVA and DCNVA were 0.37± 0.15 logMAR and 0.40± 0.13 logMAR, respectively). The defocus curve showed a peak of visual acuity at far distance with a depth-of-focus value of about 1.75D. Conclusion: Patients implanted with the new Isopure Serenity IOL with double C-loop haptics showed good visual performance at far distance with functional intermediate vision and accurate refractive outcomes.
- 1 September 2025
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 3121-3131
Open AccessClinical Outcomes of a Multicenter Study Following Implantation of an Isofocal Optic IOL with Double C-Loop Haptics
Purpose: To report clinical outcomes in patients implanted with an isofocal optic-design intraocular lens (IOL) with double C-loop haptics following cataract surgery. Methods: This was a multicentre-prospective-study involving 108 eyes (54 subjects) implanted with the Isopure Serenity (BVI, Inc). IOL. At least 3 months after the surgery, the following parameters were analysed: refraction, monocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA) and distance corrected-intermediate visual acuity (DCIVA) both at 80 and 66 cm, uncorrected near visual acuity (UNVA), and distance corrected near visual acuity (DCNVA) at 40 cm. In addition, the binocular defocus curve was measured. Results: 79.63% and 98.15% of eyes were within ± 0.50D and ± 1.00D of the target spherical equivalent, respectively. 68.41% and 98.15% of eyes had a UDVA and CDVA of 20/20 or better, respectively, with 88.89% and 99.07% achieving 20/25 or better, respectively (the mean values for UDVA and CDVA were 0.02± 0.11 and – 0.04± 0.05 logMAR, respectively). 77.14% and 39.39% of eyes achieved a DCIVA of 20/32 or better at 80 cm and 66 cm, respectively, and 90% and 72.73% achieved a DCIVA of 20/40 or better at 80 and 66 cm, respectively (the mean values for DCIVA were 0.19± 0.10 and 0.28± 0.11 logMAR, 80 cm and at 66 cm, respectively). 25% and 15.15% of eyes had a UNVA and DCNVA of 20/32 or better, respectively, with 39.81% and 31.82% achieving a UNVA and DCNVA of 20/40 or better, respectively (mean values for UNVA and DCNVA were 0.37± 0.15 logMAR and 0.40± 0.13 logMAR, respectively). The defocus curve showed a peak of visual acuity at far distance with a depth-of-focus value of about 1.75D. Conclusion: Patients implanted with the new Isopure Serenity IOL with double C-loop haptics showed good visual performance at far distance with functional intermediate vision and accurate refractive outcomes.
- 1 August 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (8) , 746
Comment on: From the editor. Current and future nomenclature and categorization of intraocular lenses
An abstract is unavailable. This article is available as a PDF only.
- 1 August 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (8) , 746
Comment on: From the editor. Current and future nomenclature and categorization of intraocular lenses
An abstract is unavailable. This article is available as a PDF only.
- Open Access
- 1 July 2025
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 2259-2269
Double C-Loop Haptic Lenses Are Rotationally Stable – A Systematic Review
The purpose of this review is to summarize the clinical rotational stability outcomes reported in patients following implantation of the POD platform with double C-loop haptics. A literature search in PubMed (US National Library of Medicine) was carried out to find publications, both prospective and retrospective, which report rotational stability outcomes in patients who were implanted with this platform after cataract or refractive lens exchange surgeries. This platform is used in different commercially available intraocular lenses (IOLs), both monofocal and trifocal, made of hydrophilic or hydrophobic material. 19 clinical peer-reviewed studies published between 2013 and 2024 were included in this review. The data reported in the clinical publications was analyzed in detail, focusing on rotational stability (mean rotation values and ranges, and percentage of eyes with some degrees of rotation), measurement methods and rotation follow-up period. Our review encompassed a total of 1428 eyes implanted with the POD platform analyzed at different follow-up periods, up to a maximum of 26 months. The mean rotation across all the studies was 2.61 °.The analysis carried out in this review leads us to conclude that the POD platform provides good rotational stability when used with different IOL models based on monofocal or trifocal designs and made using hydrophilic or hydrophobic material.
- 1 July 2025
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 2259-2269
Open AccessDouble C-Loop Haptic Lenses Are Rotationally Stable – A Systematic Review
The purpose of this review is to summarize the clinical rotational stability outcomes reported in patients following implantation of the POD platform with double C-loop haptics. A literature search in PubMed (US National Library of Medicine) was carried out to find publications, both prospective and retrospective, which report rotational stability outcomes in patients who were implanted with this platform after cataract or refractive lens exchange surgeries. This platform is used in different commercially available intraocular lenses (IOLs), both monofocal and trifocal, made of hydrophilic or hydrophobic material. 19 clinical peer-reviewed studies published between 2013 and 2024 were included in this review. The data reported in the clinical publications was analyzed in detail, focusing on rotational stability (mean rotation values and ranges, and percentage of eyes with some degrees of rotation), measurement methods and rotation follow-up period. Our review encompassed a total of 1428 eyes implanted with the POD platform analyzed at different follow-up periods, up to a maximum of 26 months. The mean rotation across all the studies was 2.61 °.The analysis carried out in this review leads us to conclude that the POD platform provides good rotational stability when used with different IOL models based on monofocal or trifocal designs and made using hydrophilic or hydrophobic material.
- 1 May 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (5) , 436
Comment on: Evidence-based functional classification of simultaneous vision intraocular lenses: seeking a global consensus by the ESCRS Functional Vision Working Group
An abstract is unavailable. This article is available as a PDF only.
- 1 May 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (5) , 436
Comment on: Evidence-based functional classification of simultaneous vision intraocular lenses: seeking a global consensus by the ESCRS Functional Vision Working Group
An abstract is unavailable. This article is available as a PDF only.
- Open Access
- 1 April 2024
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 18, 997-1007
Visual and Refractive Outcomes of a New Hydrophobic Trifocal Toric Intraocular Lens
Purpose: To evaluate the visual outcomes and efficacy of astigmatism correction using a new hydrophobic trifocal toric intraocular lens (IOL). Methods: This study involved 62 eyes implanted with the FineVision HP Toric IOL. The visual and refractive outcomes were assessed preoperatively and 6 weeks after the surgery. Specifically, monocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA) at 80 and 60 cm and uncorrected near visual acuity at (UNVA) at 40 cm were evaluated. The rotational stability of the lens was also assessed. Results: Sixty-one eyes (98.39%) were within ± 1.00D and 55 eyes (88.71%) were within ± 0.50 D of spherical equivalent, with a mean value of 0.09± 0.39 D. 51 (82.26%) and 61 (98.39%) eyes had a UDVA of ≥ 20/20 and ≥ 20/25, respectively, and for CDVA these values were as follows: 59 (95.16%) and 62 eyes (100%), respectively. The mean UDVA and CDVA were 0.01± 0.06 and − 0.01± 0.04logMAR, respectively. Greater than or equal to unaided 20/20 vision was achieved at 40 cm in 42 (67.74%), UIVA at 60 cm in 42 (67.74%) and 50 eyes (80.65%) at 80 cm. Those achieving ≥ 20/25 were 56 (90.32%, 40 cm), 59 (95.16%, 60 cm), and 62 eyes (100%, 80 cm). Postoperative mean values were 0.04± 0.07, 0.03± 0.07, and 0.00± 0.07logMAR for UCNVA, UIVA at 60 cm, and UIVA at 80 cm, respectively. The mean rotation of the IOL was 5.8 degrees. Conclusion: This hydrophobic trifocal toric IOL provides good refractive outcomes with excellent visual acuity across multiple distances, providing a full range of focus.
- 1 April 2024
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 18, 997-1007
Open AccessVisual and Refractive Outcomes of a New Hydrophobic Trifocal Toric Intraocular Lens
Purpose: To evaluate the visual outcomes and efficacy of astigmatism correction using a new hydrophobic trifocal toric intraocular lens (IOL). Methods: This study involved 62 eyes implanted with the FineVision HP Toric IOL. The visual and refractive outcomes were assessed preoperatively and 6 weeks after the surgery. Specifically, monocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA) at 80 and 60 cm and uncorrected near visual acuity at (UNVA) at 40 cm were evaluated. The rotational stability of the lens was also assessed. Results: Sixty-one eyes (98.39%) were within ± 1.00D and 55 eyes (88.71%) were within ± 0.50 D of spherical equivalent, with a mean value of 0.09± 0.39 D. 51 (82.26%) and 61 (98.39%) eyes had a UDVA of ≥ 20/20 and ≥ 20/25, respectively, and for CDVA these values were as follows: 59 (95.16%) and 62 eyes (100%), respectively. The mean UDVA and CDVA were 0.01± 0.06 and − 0.01± 0.04logMAR, respectively. Greater than or equal to unaided 20/20 vision was achieved at 40 cm in 42 (67.74%), UIVA at 60 cm in 42 (67.74%) and 50 eyes (80.65%) at 80 cm. Those achieving ≥ 20/25 were 56 (90.32%, 40 cm), 59 (95.16%, 60 cm), and 62 eyes (100%, 80 cm). Postoperative mean values were 0.04± 0.07, 0.03± 0.07, and 0.00± 0.07logMAR for UCNVA, UIVA at 60 cm, and UIVA at 80 cm, respectively. The mean rotation of the IOL was 5.8 degrees. Conclusion: This hydrophobic trifocal toric IOL provides good refractive outcomes with excellent visual acuity across multiple distances, providing a full range of focus.
- 18 May 2023
- Published by Springer Nature
- p. 121-125
Measurement of Endothelial Cells
- 4 April 2019
- Published by BMJ in British Journal of Ophthalmology
- Vol. 104 (3) , 437-442
Comparison of anterior capsulotomy techniques: continuous curvilinear capsulorhexis, femtosecond laser-assisted capsulotomy and selective laser capsulotomy
Purpose To compare the anterior capsulotomy edge tear strength created by manual continuous curvilinear capsulorhexis (CCC), femtosecond laser-assisted capsulotomy (FLACS), and selective laser capsulotomy (SLC). Setting Singapore National Eye Centre, Singapore and Excel-Lens, Livermore, California, USA. Design Three armed study in paired human eyes. Methods Capsulotomies were performed in 60 cadaver eyes of 30 donors using CCC, Victus Femtosecond Laser, (Bausch & Lomb, Rochester, New York, USA) or CAPSULaser, (Excel-Lens, Los Gatos, California, USA). Three pairwise study groups each involved 10 pairs of eyes. Study group 1: SLC eyes compared with fellow eyes with CCC. Study group 2: CCC eyes compared with fellow eyes with FLACS. Study group 3: FLACS eyes compared with fellow eyes with SLC. A shoe-tree method was used to apply load to the capsulotomy edge, and Instron tensile stress instrument measured distension and threshold load applied to initiate capsule fracture. Relative fracture strengths and distension of CCC, FLACS and SLC were determined. Scanning electron microscopy (SEM) of capsule edges were reviewed Results Anterior capsulotomies behave as non-linear elastic (elastomeric) systems when exposed to an external load. The pairwise study demonstrated that the SLC fracture strength was superior to that of CCC by a factor of 1.46-fold with SLC 277±38 mN versus CCC with 190±37 mN. Furthermore, CCC fracture strength was superior to that of FLACS by a factor of 1.28-fold with CCC 186 + 37 mN versus FLACS 145 ± 35 mN (p < 0.001). This was determined by statistical analysis utilising the Wilcoxon matched-pairs signed-ranks test and in accordance with the Consolidated Standards of Reporting Trials guidelines. The capsule edge of SLC on SEM demonstrated a rolled over edge anteriorly and an alteration of collagen. Conclusions The strength of the capsulotomy edge for SLC was significantly stronger than that of CCC which and both were significantly stronger than FLACS. The relative strengths can be explained by SEM of each type of capsulotomy.
- 4 April 2019
- Published by BMJ in British Journal of Ophthalmology
- Vol. 104 (3) , 437-442
Comparison of anterior capsulotomy techniques: continuous curvilinear capsulorhexis, femtosecond laser-assisted capsulotomy and selective laser capsulotomy
Purpose To compare the anterior capsulotomy edge tear strength created by manual continuous curvilinear capsulorhexis (CCC), femtosecond laser-assisted capsulotomy (FLACS), and selective laser capsulotomy (SLC). Setting Singapore National Eye Centre, Singapore and Excel-Lens, Livermore, California, USA. Design Three armed study in paired human eyes. Methods Capsulotomies were performed in 60 cadaver eyes of 30 donors using CCC, Victus Femtosecond Laser, (Bausch & Lomb, Rochester, New York, USA) or CAPSULaser, (Excel-Lens, Los Gatos, California, USA). Three pairwise study groups each involved 10 pairs of eyes. Study group 1: SLC eyes compared with fellow eyes with CCC. Study group 2: CCC eyes compared with fellow eyes with FLACS. Study group 3: FLACS eyes compared with fellow eyes with SLC. A shoe-tree method was used to apply load to the capsulotomy edge, and Instron tensile stress instrument measured distension and threshold load applied to initiate capsule fracture. Relative fracture strengths and distension of CCC, FLACS and SLC were determined. Scanning electron microscopy (SEM) of capsule edges were reviewed Results Anterior capsulotomies behave as non-linear elastic (elastomeric) systems when exposed to an external load. The pairwise study demonstrated that the SLC fracture strength was superior to that of CCC by a factor of 1.46-fold with SLC 277±38 mN versus CCC with 190±37 mN. Furthermore, CCC fracture strength was superior to that of FLACS by a factor of 1.28-fold with CCC 186 + 37 mN versus FLACS 145 ± 35 mN (p < 0.001). This was determined by statistical analysis utilising the Wilcoxon matched-pairs signed-ranks test and in accordance with the Consolidated Standards of Reporting Trials guidelines. The capsule edge of SLC on SEM demonstrated a rolled over edge anteriorly and an alteration of collagen. Conclusions The strength of the capsulotomy edge for SLC was significantly stronger than that of CCC which and both were significantly stronger than FLACS. The relative strengths can be explained by SEM of each type of capsulotomy.
- 1 March 2019
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 45 (3) , 355-360
Parameters affecting anterior capsulotomy tear strength and distension
Purpose To study the effects of anterior capsulotomy diameter and discontinuity on tear threshold load and distension for the technique of continuous curvilinear capsulorhexis (CCC). Setting Singapore National Eye Centre, Singapore, and CapsuLaser Inc., Livermore, California, USA. Design Two separate randomized pairwise cadaver eye preclinical studies. Methods Capsulotomies were performed in 40 cadaver eyes of 20 donors using CCC. The pairwise comparisons were divided into 2 study groups: Study A: Continuous versus discontinuous capsulotomies; Study B: Capsulotomy diameter of 5.0 mm and smaller versus diameters of 5.2 mm and larger. A shoe-tree method was used to apply load to the capsulotomy rim, and the Instron tensile stress instrument measured threshold load and distension to initiate a capsular tear. Wilcoxon matched-pairs signed-rank tests were performed to assess statistical superiority. Results In Study Group A, all pairs demonstrated that continuous capsulotomies were better than discontinuous capsulotomies for both the anterior tear threshold load and distension (P < .01). In Study Group B, 80% of the pairs demonstrated that diameters of 5.2 mm and larger were better than those of 5.0 mm and smaller diameter (P < .05). Conclusions Anterior capsulotomies behave as nonlinear elastic (elastomeric) systems when exposed to an external load and distension. This study demonstrated that continuous circular capsulotomies were more resistant to anterior tears than discontinuous capsulotomies. A point of irregularity or a defect in a capsulotomy rim has a high probability of being the tear initiation point. Furthermore, larger diameter capsulotomies were more resistant to anterior tears than smaller capsulotomies.
- 1 March 2019
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 45 (3) , 355-360
Parameters affecting anterior capsulotomy tear strength and distension
Purpose To study the effects of anterior capsulotomy diameter and discontinuity on tear threshold load and distension for the technique of continuous curvilinear capsulorhexis (CCC). Setting Singapore National Eye Centre, Singapore, and CapsuLaser Inc., Livermore, California, USA. Design Two separate randomized pairwise cadaver eye preclinical studies. Methods Capsulotomies were performed in 40 cadaver eyes of 20 donors using CCC. The pairwise comparisons were divided into 2 study groups: Study A: Continuous versus discontinuous capsulotomies; Study B: Capsulotomy diameter of 5.0 mm and smaller versus diameters of 5.2 mm and larger. A shoe-tree method was used to apply load to the capsulotomy rim, and the Instron tensile stress instrument measured threshold load and distension to initiate a capsular tear. Wilcoxon matched-pairs signed-rank tests were performed to assess statistical superiority. Results In Study Group A, all pairs demonstrated that continuous capsulotomies were better than discontinuous capsulotomies for both the anterior tear threshold load and distension (P < .01). In Study Group B, 80% of the pairs demonstrated that diameters of 5.2 mm and larger were better than those of 5.0 mm and smaller diameter (P < .05). Conclusions Anterior capsulotomies behave as nonlinear elastic (elastomeric) systems when exposed to an external load and distension. This study demonstrated that continuous circular capsulotomies were more resistant to anterior tears than discontinuous capsulotomies. A point of irregularity or a defect in a capsulotomy rim has a high probability of being the tear initiation point. Furthermore, larger diameter capsulotomies were more resistant to anterior tears than smaller capsulotomies.