3D steady‐state diffusion‐weighted imaging with trajectory using radially batched internal navigator echoes (TURBINE)
Open Access
- 26 October 2009
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 63 (1) , 235-242
Abstract
While most diffusion‐weighted imaging (DWI) is acquired using single‐shot diffusion‐weighted spin‐echo echo‐planar imaging, steady‐state DWI is an alternative method with the potential to achieve higher‐resolution images with less distortion. Steady‐state DWI is, however, best suited to a segmented three‐dimensional acquisition and thus requires three‐dimensional navigation to fully correct for motion artifacts. In this paper, a method for three‐dimensional motion‐corrected steady‐state DWI is presented. The method uses a unique acquisition and reconstruction scheme named trajectory using radially batched internal navigator echoes (TURBINE). Steady‐state DWI with TURBINE uses slab‐selection and a short echo‐planar imaging (EPI) readout each pulse repetition time. Successive EPI readouts are rotated about the phase‐encode axis. For image reconstruction, batches of cardiac‐synchronized readouts are used to form three‐dimensional navigators from a fully sampled central k‐space cylinder. In vivo steady‐state DWI with TURBINE is demonstrated in human brain. Motion artifacts are corrected using refocusing reconstruction and TURBINE images prove less distorted compared to two‐dimensional single‐shot diffusion‐weighted‐spin‐EPI. Magn Reson Med, 2010.Keywords
This publication has 23 references indexed in Scilit:
- High resolution diffusion-weighted imaging in fixed human brain using diffusion-weighted steady state free precessionNeuroImage, 2009
- Simultaneous phase correction and SENSE reconstruction for navigated multi‐shot DWI with non‐cartesian k‐space samplingMagnetic Resonance in Medicine, 2005
- Self‐navigated multishot echo‐planar pulse sequence for high‐resolution diffusion‐weighted imagingMagnetic Resonance in Medicine, 2005
- Quantitative diffusion imaging with steady‐state free precessionMagnetic Resonance in Medicine, 2004
- Nonlinear phase correction for navigated diffusion imagingMagnetic Resonance in Medicine, 2003
- Diffusion tensor imaging using single‐shot SENSE‐EPIMagnetic Resonance in Medicine, 2002
- Advances in sensitivity encoding with arbitrary k‐space trajectoriesMagnetic Resonance in Medicine, 2001
- Image reconstruction for echo planar imaging with nonequidistant k‐space samplingMagnetic Resonance in Medicine, 1992
- Effect of diffusion on the steady-state magnetization with pulsed field gradientsJournal of Magnetic Resonance (1969), 1990
- Intravoxel incoherent motion imaging using steady‐state free precessionMagnetic Resonance in Medicine, 1988