Transconjunctival XEN45 Implantation for Glaucoma Performed at the Slit Lamp: A Pilot Study
Open Access
- 30 June 2022
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 31 (8) , 675-681
Abstract
Précis: The ab externo implantation of a gel microstent is a novel, minimally invasive glaucoma surgery performed at the slit lamp that is effective for lowering intraocular pressure in patients with uncontrolled glaucoma. Purpose: To evaluate the intraocular pressure (IOP) -lowering effect of gel microstent (XEN® Gel Stent, Allergan, Irvine, CA) implantation using an ab externo approach in an office setting. Patients and Methods: This retrospective, multicenter chart review examined outcomes in patients with uncontrolled glaucoma receiving maximally tolerated medical therapy, who underwent slit lamp ab externo gel stent implantation. Postoperative IOP, the number of glaucoma medications, the final position of the stent and the needling rate were analyzed. Assessments occurred 1 day, 1 week and 1, 3, 6 and 12 months after implantation. Treatment success was defined as IOP ≥6 mmHg and ≤18 mmHg with ≥20% reduction from presurgical IOP, with or without medications. Results: Thirty-four (34) eyes from 28 patients were included. Mean preoperative IOP was 24.1±8.0 mmHg on 3.2±0.9 glaucoma medications. At 12 months postoperative, IOP was reduced to 15.4±4.7 mmHg on 0.6±1.0 medications; 46.9% and 81.3% of eyes achieved complete and partial success, respectively. The gel stent was properly positioned in 94.1% of eyes after one attempt at implantation and in 100% of eyes after a second attempt. In addition to malpositioning, observed complications included occlusion, erosion, and endophthalmitis following anterior chamber (AC) reformation. Adjunctive needling was required in 21% of implanted eyes. Conclusion: Slit-lamp-based transconjonctival XEN45 implantation reduced intraocular pressure in glaucoma patients in the first year of this pilot study and was most commonly associated with wound leak and hypotonic among other adverse events.Keywords
This publication has 18 references indexed in Scilit:
- Early Clinical Results of a Novel Ab Interno Gel Stent for the Surgical Treatment of Open-angle GlaucomaJournal of Glaucoma, 2016
- Outcomes of Sequential Glaucoma Drainage Implants in Refractory GlaucomaJournal of Glaucoma, 2016
- Global Prevalence of Glaucoma and Projections of Glaucoma Burden through 2040Ophthalmology, 2014
- Causes of vision loss worldwide, 1990–2010: a systematic analysisThe Lancet Global Health, 2013
- The carbon footprint of cataract surgeryEye, 2013
- Treatment Outcomes in the Tube Versus Trabeculectomy (TVT) Study After Five Years of Follow-upAmerican Journal of Ophthalmology, 2012
- Postoperative Complications in the Tube Versus Trabeculectomy (TVT) Study During Five Years of Follow-upAmerican Journal of Ophthalmology, 2012
- Micro-invasive glaucoma surgeryCurrent Opinion in Ophthalmology, 2012
- Perioperative Complications of Trabeculectomy in the Collaborative Initial Glaucoma Treatment Study (CIGTS)American Journal of Ophthalmology, 2005
- Vision related quality of life and topical glaucoma treatment side effectsHealth and Quality of Life Outcomes, 2003