Darana Yuen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Darana Yuen has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Eric Tam
Uptown Eye Specialists, Vaughan, Canada; Department of Ophthalmology & Vision Sciences, University of Toronto, Toronto, Canada; William Osler Health System, Brampton, Ontario, Canada
1 shared publication- Eric Tam
Uptown Eye Specialists, Vaughan, Ontario, Canada
1 shared publication - Fahmeeda Murtaza
Temerty Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
1 shared publication Qayim Kaba
School of Medicine, Cardiff University, Cardiff, United Kingdom
1 shared publication- Qayim Kaba
Cardiff University, Cardiff, Wales, UK
1 shared publication - Shawn L. Cohen
Department of Ophthalmology, McGill University, Montreal, Quebec
1 shared publication
Latest Publications
- Open Access
- 1 May 2024
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 18, 1295-1312
Micropulse Transscleral Cyclophotocoagulation in Non-Incisional Eyes with Ocular Hypertension and Primary Open-Angle Glaucoma
Purpose: To investigate the safety and effectiveness of micropulse transscleral cyclophotocoagulation (MPTSCPC) in non-incisional eyes with ocular hypertension (OHT) and early, moderate, and severe primary open-angle glaucoma (POAG). Methods: Retrospective cohort study of eyes that underwent MPTSCPC from 2016 to 2019 at an outpatient clinic in Canada. Eyes were excluded if any incisional procedures, except cataract surgery, were performed prior to MPTSCPC treatment. Laser power ranged from 900 to 2500mW. Results: A total of 153 eyes from 93 patients were included (OHT n=22; early POAG n=46; moderate POAG n=35; severe POAG n=50). The baseline IOP was 18.37 ± 4.76mmHg in the total cohort. All cohorts experienced a significant mean IOP reduction by final follow-up (total p< 0.001; OHT p=0.003; early POAG p< 0.001; moderate POAG p=0.022; severe POAG p=0.015). Overall, 52.9% of eyes achieved an IOP reduction of ≥ 20% from baseline to final follow-up (OHT 59.1%; early POAG 58.7%; moderate POAG 45.7%; severe POAG 50.0%). There was worsening in best-corrected visual acuity in the total cohort (mean difference=0.11 ± 0.36 logMAR, p=0.11), mostly attributable to cataract progression (34.1% of phakic eyes) and ocular surface disease (7.2%). The number of topical medications and drug classes remained unchanged in the total cohort (p=0.425 and p=0.791, respectively). Twenty-two eyes (14.4%) required retreatment, which provided an additional IOP reduction of 1.26mmHg (p=0.344). By final follow-up, 8 eyes (5.2%) required escalation to incisional procedures. Conclusion: MPTSCPC is a safe and effective adjunct IOP-lowering treatment in non-incisional eyes with OHT and POAG.
- 1 May 2024
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 18, 1295-1312
Open AccessMicropulse Transscleral Cyclophotocoagulation in Non-Incisional Eyes with Ocular Hypertension and Primary Open-Angle Glaucoma
Purpose: To investigate the safety and effectiveness of micropulse transscleral cyclophotocoagulation (MPTSCPC) in non-incisional eyes with ocular hypertension (OHT) and early, moderate, and severe primary open-angle glaucoma (POAG). Methods: Retrospective cohort study of eyes that underwent MPTSCPC from 2016 to 2019 at an outpatient clinic in Canada. Eyes were excluded if any incisional procedures, except cataract surgery, were performed prior to MPTSCPC treatment. Laser power ranged from 900 to 2500mW. Results: A total of 153 eyes from 93 patients were included (OHT n=22; early POAG n=46; moderate POAG n=35; severe POAG n=50). The baseline IOP was 18.37 ± 4.76mmHg in the total cohort. All cohorts experienced a significant mean IOP reduction by final follow-up (total p< 0.001; OHT p=0.003; early POAG p< 0.001; moderate POAG p=0.022; severe POAG p=0.015). Overall, 52.9% of eyes achieved an IOP reduction of ≥ 20% from baseline to final follow-up (OHT 59.1%; early POAG 58.7%; moderate POAG 45.7%; severe POAG 50.0%). There was worsening in best-corrected visual acuity in the total cohort (mean difference=0.11 ± 0.36 logMAR, p=0.11), mostly attributable to cataract progression (34.1% of phakic eyes) and ocular surface disease (7.2%). The number of topical medications and drug classes remained unchanged in the total cohort (p=0.425 and p=0.791, respectively). Twenty-two eyes (14.4%) required retreatment, which provided an additional IOP reduction of 1.26mmHg (p=0.344). By final follow-up, 8 eyes (5.2%) required escalation to incisional procedures. Conclusion: MPTSCPC is a safe and effective adjunct IOP-lowering treatment in non-incisional eyes with OHT and POAG.
- Open Access
- 30 June 2022
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 31 (8) , 675-681
Transconjunctival XEN45 Implantation for Glaucoma Performed at the Slit Lamp: A Pilot Study
Précis: The ab externo implantation of a gel microstent is a novel, minimally invasive glaucoma surgery performed at the slit lamp that is effective for lowering intraocular pressure in patients with uncontrolled glaucoma. Purpose: To evaluate the intraocular pressure (IOP) -lowering effect of gel microstent (XEN® Gel Stent, Allergan, Irvine, CA) implantation using an ab externo approach in an office setting. Patients and Methods: This retrospective, multicenter chart review examined outcomes in patients with uncontrolled glaucoma receiving maximally tolerated medical therapy, who underwent slit lamp ab externo gel stent implantation. Postoperative IOP, the number of glaucoma medications, the final position of the stent and the needling rate were analyzed. Assessments occurred 1 day, 1 week and 1, 3, 6 and 12 months after implantation. Treatment success was defined as IOP ≥6 mmHg and ≤18 mmHg with ≥20% reduction from presurgical IOP, with or without medications. Results: Thirty-four (34) eyes from 28 patients were included. Mean preoperative IOP was 24.1±8.0 mmHg on 3.2±0.9 glaucoma medications. At 12 months postoperative, IOP was reduced to 15.4±4.7 mmHg on 0.6±1.0 medications; 46.9% and 81.3% of eyes achieved complete and partial success, respectively. The gel stent was properly positioned in 94.1% of eyes after one attempt at implantation and in 100% of eyes after a second attempt. In addition to malpositioning, observed complications included occlusion, erosion, and endophthalmitis following anterior chamber (AC) reformation. Adjunctive needling was required in 21% of implanted eyes. Conclusion: Slit-lamp-based transconjonctival XEN45 implantation reduced intraocular pressure in glaucoma patients in the first year of this pilot study and was most commonly associated with wound leak and hypotonic among other adverse events.
- 30 June 2022
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 31 (8) , 675-681
Open AccessTransconjunctival XEN45 Implantation for Glaucoma Performed at the Slit Lamp: A Pilot Study
Précis: The ab externo implantation of a gel microstent is a novel, minimally invasive glaucoma surgery performed at the slit lamp that is effective for lowering intraocular pressure in patients with uncontrolled glaucoma. Purpose: To evaluate the intraocular pressure (IOP) -lowering effect of gel microstent (XEN® Gel Stent, Allergan, Irvine, CA) implantation using an ab externo approach in an office setting. Patients and Methods: This retrospective, multicenter chart review examined outcomes in patients with uncontrolled glaucoma receiving maximally tolerated medical therapy, who underwent slit lamp ab externo gel stent implantation. Postoperative IOP, the number of glaucoma medications, the final position of the stent and the needling rate were analyzed. Assessments occurred 1 day, 1 week and 1, 3, 6 and 12 months after implantation. Treatment success was defined as IOP ≥6 mmHg and ≤18 mmHg with ≥20% reduction from presurgical IOP, with or without medications. Results: Thirty-four (34) eyes from 28 patients were included. Mean preoperative IOP was 24.1±8.0 mmHg on 3.2±0.9 glaucoma medications. At 12 months postoperative, IOP was reduced to 15.4±4.7 mmHg on 0.6±1.0 medications; 46.9% and 81.3% of eyes achieved complete and partial success, respectively. The gel stent was properly positioned in 94.1% of eyes after one attempt at implantation and in 100% of eyes after a second attempt. In addition to malpositioning, observed complications included occlusion, erosion, and endophthalmitis following anterior chamber (AC) reformation. Adjunctive needling was required in 21% of implanted eyes. Conclusion: Slit-lamp-based transconjonctival XEN45 implantation reduced intraocular pressure in glaucoma patients in the first year of this pilot study and was most commonly associated with wound leak and hypotonic among other adverse events.
- 1 May 2020
- Published by Elsevier in Ophthalmology Glaucoma
- Vol. 3 (3) , 181-189
The Effectiveness and Safety of Micropulse Cyclophotocoagulation in the Treatment of Ocular Hypertension and Glaucoma
- 1 May 2020
- Published by Elsevier in Ophthalmology Glaucoma
- Vol. 3 (3) , 181-189
The Effectiveness and Safety of Micropulse Cyclophotocoagulation in the Treatment of Ocular Hypertension and Glaucoma