Pulsed Critical Field Measurements in Magnetic Systems
Authors:
- 1 March 1962
- journal article
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 33 (3) , 1289-1290
Abstract
Pulsed field magnetic moment measurements in several magnetic systems are briefly summarized. Particularly high sensitivity is attained for systems which exhibit a nonlinear variation of magnetization versus applied field, e.g., ``spin‐flop.'' Changes of magnetization as small as 0.1 gauss could be observed with applied fields of over 100 kgauss under favorable circumstances. Critical fields for Cr2O3 and (Cr2O3)0.9·(Al2O3)0.1 from 4.2°K to about 0.95 TN and the corresponding calculated values of (2λK)½ are presented, where λ is the exchange constant and K is the anisotropy energy. The values of (2λK)½ agree with earlier antiferromagnetic resonance measurements in similar crystals. Results of measurements in antiferromagnetic MnF2, CoF2, and FeTiO3, and in metamagnetic FeCl2 and CoCl2 are briefly discussed. Application of the method to paramagnets is also indicated.Keywords
This publication has 3 references indexed in Scilit:
- Antiferromagnetic Resonance in (Cr2O3)1−x·(Al2O3)x Single CrystalsJournal of Applied Physics, 1961
- Spin-Flopping in MnF2 by High Magnetic FieldsJournal of Applied Physics, 1961
- Neutron Diffraction Investigations of the Magnetic Ordering in Fe, Co, Fe, and CoPhysical Review B, 1959