Q-value customized versus wavefront-optimized ablation in femtosecond laser-assisted LASIK for myopia and myopic astigmatism: a prospective contralateral comparative study
Open Access
- 2 November 2022
- journal article
- research article
- Published by Springer Nature in Eye and Vision
- Vol. 9 (1) , 1-13
Abstract
Background: Corneal refractive surgery for myopia results in an oblate shift with increased postoperative aberrations inversely affecting the quality of vision. Aspheric ablation profiles have been introduced to minimize such a problem. The aim of this study was to compare changes in corneal asphericity, central and mid-peripheral pachymetry between the Q-value customized and the wavefront-optimized (WFO) ablation profiles. Methods: A prospective, comparative non-randomized fellow eye study was conducted. Eighty eyes of 40 eligible patients underwent femtosecond laser-assisted laser in situ keratomileusis for myopia and myopic astigmatism. In each patient, the more myopic eye was included in the custom-Q ablation experimental group and the other less myopic eye was included in the WFO control group. For the custom-Q group, the target asphericity was set to the preoperative Q-value. Corneal asphericity, central and mid-peripheral pachymetric changes and the root mean square of corneal higher-order aberrations (RMSh) were assessed 6 months following surgery. Visual and refractive outcomes were also evaluated in both platforms 6 months postoperatively. Results: The mean preoperative refractive spherical equivalent was significantly more myopic in the custom-Q group than in the WFO group (P = 0.001). The mean Q-value changed from − 0.2 ± 0.1 to 0.6 ± 0.7 and from − 0.2 ± 0.1 to 0.4 ± 0.5 in the custom-Q and WFO groups, respectively. The oblate shift in corneal asphericity was not significantly different between both treatment groups (P = 0.094). The mean ablation depth at the pupillary center was significantly greater in the custom-Q group (P = 0.011), while there was no significant difference at the mid-peripheral pachymetry (P = 0.256). The RMSh significantly increased in both treatment profiles (P < 0.001) with no significant difference between the two groups (P = 0.06). The uncorrected distance visual acuity (UDVA) and the manifest refraction spherical equivalents (MRSE) significantly improved in both treatment groups (P < 0.001). Conclusions: The custom-Q treatment profile with target asphericity set at the preoperative Q-value achieved comparable outcomes vs. the WFO profile in terms of postoperative corneal asphericity and mid-peripheral pachymetry despite the greater amount of ablation, the smaller optical zone, and the resulting increase in postoperative corneal flattening in the custom-Q group. Trial registration (Clinicaltrials.gov): NCT04738903, 4 February 2021- Retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT04738903Keywords
Funding Information
- Assiut University
This publication has 29 references indexed in Scilit:
- Association Between the Percent Tissue Altered and Post–Laser In Situ Keratomileusis Ectasia in Eyes With Normal Preoperative TopographyAmerican Journal of Ophthalmology, 2014
- Q-value customized ablation (custom-Q) versus wavefront optimized ablation for primary myopia and myopic astigmatismInternational Ophthalmology, 2013
- Multi-aspheric description of the myopic cornea after different refractive treatments and its correlation with corneal higher order aberrationsJournal of Optometry, 2012
- Wavefront-Guided and Aspheric Ablation for Myopia – One-Year Results of the Zyoptix Personalized Treatment Advanced AlgorithmAmerican Journal of Ophthalmology, 2012
- Wavefront Ablation Profiles in Refractive Surgery: Description, Results, and LimitationsJournal of Refractive Surgery, 2012
- Transitioning to Optimized Correction with the WaveLight ALLEGRETTO WAVE: Case Distribution, Visual Outcomes, and Wavefront AberrationsJournal of Refractive Surgery, 2010
- Distribution of corneal spherical aberration in a comprehensive ophthalmology practice and whether keratometry can predict aberration valuesJournal of Cataract & Refractive Surgery, 2007
- Q-factor customized ablation profile for the correction of myopic astigmatismJournal of Cataract & Refractive Surgery, 2006
- Wavefront-optimized ablation profilesJournal of Cataract & Refractive Surgery, 2004
- Contrast sensitivity after laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2002