Diagnostic quality of CT pulmonary angiography in pulmonary thromboembolism: A comparison of three different kV values
Authors:
Open Access
- 1 January 2013
- journal article
- clinical trial
- Published by International Scientific Information, Inc. in Medical Science Monitor
- Vol. 19, 908-915
Abstract
Our purpose was to evaluate the effectiveness of different kilovolt (kV) uses in computed tomography pulmonary angiography (CTPA) in the diagnosis of pulmonary thromboembolism (PTE). We also aimed to establish the optimal kV value and investigate the possibility of obtaining appropriate imaging quality with minimal radiation dose. We compared 120, 100, and 80 kV CTPA for 90 patients in whom PTE was clinically considered. The examinations were carried out using a 128 multislice CT device (Definition AS, Siemens Medical Solutions, Forchheim, Germany). Each kV value was used on 30 patients in 3 groups. Patients in all groups were compared with respect to the mean radiation dose they received, pulmonary arterial attenuation values, image quality, and motion artefacts. With respect to pulmonary arterial attenuation values, imaging with 80 kV yielded significantly higher values (p<0.05). However, no difference was found between 120 kV, 100 kV, and 80 kV with respect to image quality. Similarly, no significant difference was detected between the groups with respect to pulmonary artery contrasting and motion artefacts. Statistically significant differences were present in DLP values and effective dose among all 3 groups (p<0.001). Using 80 kV as the low value in CTPA imaging for patients pre-diagnosed with PTE will increase the density of pulmonary arteries and decrease the amount of radiation received.Keywords
This publication has 14 references indexed in Scilit:
- Image Quality and Radiation Dose of Pulmonary CT Angiography Performed Using 100 and 120 kVpAmerican Journal of Roentgenology, 2012
- Progressive intra-individual radiation dose reduction during CT surveillance of a patient with alcapa syndromeDiagnostic and Interventional Radiology, 2012
- Diagnostic Accuracy of Pulmonary CT Angiography at Low Tube Voltage: Intraindividual Comparison of a Normal-Dose Protocol at 120 kVp and a Low-Dose Protocol at 80 kVp Using Reduced Amount of Contrast Medium in a Simulation StudyAmerican Journal of Roentgenology, 2011
- The value of computed tomographic obstruction index in the identification of massive pulmonary thromboembolismDiagnostic and Interventional Radiology, 2011
- The analysis of non-thromboembolic findings encountered in multidetector computed tomography pulmonary angiography studies in patients with suspected pulmonary embolismTurkish Journal of Emergency Medicine, 2011
- CT Angiography of Pulmonary Arteries to Detect Pulmonary Embolism: Improvement of Vascular Enhancement with Low Kilovoltage SettingsRadiology, 2006
- Radiation Dose Estimates From Cardiac Multislice Computed Tomography in Daily PracticeCirculation, 2006
- Aorto-iliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation doseEuropean Radiology, 2004
- New CT Index to Quantify Arterial Obstruction in Pulmonary EmbolismAmerican Journal of Roentgenology, 2001
- Trends in the Incidence of Deep Vein Thrombosis and Pulmonary EmbolismArchives of internal medicine (1960), 1998