Noninvasive measurement of instantaneous, radial artery blood pressure
Authors:
- S. TanakaSTS. Tanaka
- Shumei GaoSGShumei Gao
- M. NogawaMNM. Nogawa
- K.-I. YamakoshiKYK.-I. Yamakoshi
- 11 July 2005
- journal article
- clinical trial
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Engineering in Medicine and Biology Magazine
- Vol. 24 (4) , 32-37
Abstract
A new prototype system for the noninvasive measurement of instantaneous blood pressure (BP) in the human radial artery has been developed. The system is based on the volume-compensation method, but several components were newly designed, namely, a disk-type cuff for local pressurization and a nozzle-flapper-type electro-pneumatic converter (EPC) for the cuff-pressure control. Results of experiments indicated that, using the disk-type cuff, the radial artery could be completely compressed, and the newly devised EPC had sufficient frequency response for BP measurement in humans. It was also found that the prototype system comprising these components was capable of noninvasively measuring instantaneous BP in the human radial artery, not only under rest conditions but also in a stressful condition, such as during the cold pressor test. In conclusion, the newly developed local pressurization technique appears promising as a useful and helpful means for instantaneous BP monitoring over longer periods of time than have previously been possible. Using this method, it is possible to construct an instrument that is more compact and more comfortable for the subject to use than a conventional commercial instrument. Finally, it has been reported that it may be possible to monitor cardiac output continuously by BP waveform analysis. Thus, continuous cardiac output monitoring might be another potential and important application of the newly designed instrument.Keywords
This publication has 13 references indexed in Scilit:
- Beat-to-beat stroke volume estimation from aortic pressure waveform in conscious rats: comparison of modelsAmerican Journal of Physiology-Heart and Circulatory Physiology, 2001
- Noninvasive cardiac output measurement in orthostasis: pulse contour analysis compared with acetylene rebreathingJournal of Applied Physiology, 1999
- Continuous stroke volume monitoring by modelling flow from non-invasive measurement of arterial pressure in humans under orthostatic stressClinical Science, 1999
- Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording.Hypertension, 1993
- Ambulatory monitoring of indirect beat-to-beat arterial pressure in human fingers by a volume-compensation methodMedical & Biological Engineering & Computing, 1991
- Continuous cardiac output monitoring by pulse contour during cardiac surgeryEuropean Heart Journal, 1990
- Arterial tonometry: Review and analysisJournal of Biomechanics, 1983
- New oscillometric method for indirect measurement of systolic and mean arterial pressure in the human finger. Part 2: correlation studyMedical & Biological Engineering & Computing, 1982
- New oscillometric method for indirect measurement of systolic and mean arterial pressure in the human finger. Part 1: Model experimentMedical & Biological Engineering & Computing, 1982
- Indirect Measurement of Instantaneous Arterial Blood Pressure in the Human Finger by the Vascular Unloading TechniqueIEEE Transactions on Biomedical Engineering, 1980