Shinobu Tanaka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shinobu Tanaka has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Masamichi Nogawa
Kanazawa University
7 shared publications - Ken-Ichi Yamakoshi
Graduate School of Natural Science & Technology, Kanazawa University, Kakuma, Kanazawa 920-1192, Japan
3 shared publications - Peter Rolfe
Oxford BioHorizons Ltd
3 shared publications - Takehiro Yamakoshi
Graduate School of Natural Sci. & Tech., Kanazawa Univ., Kanazawa, Japan
3 shared publications - Yukihiro Sawada
Sapporo Medical University
3 shared publications K. Yamakoshi
Graduate School of Natural Science and Technology, Kanazawa University, 920-1192 Japan
2 shared publications
Latest Publications
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2012 (1094687X) , 5765-5768
Development of a new aortoscope system for the use of endovascular intervention
“Balloon aortoscopy” is a technique for viewing inner wall of aorta and used in clinics [1, 2]. By this method, endoluminal aortic surface could be clearly monitored, however, during this period, the aortic blood flow is blocked off by the inflated balloon. To solve this clinical problem, we have been developing a prototype aortoscope system without blocking off aortic flow aiming for the use of an assistive technique for endovascular interventions such as stent-graft placement for aortic aneurysm and have been evaluating through in vitro and in vivo tests. The technique introduced for this purpose was the use of intermittent and instantaneous saline jet controlled by a high-speed electromagnetic valve synchronized to heart beat (diastolic phase). In the previous study, we designed an endoscope with two channels (one for saline discharge and the other for forceps insertion), and confirmed the validity of this method by in vitro and in vivo tests [3, 4]. Based on these findings, in this study, we have newly designed a conventional and low price endoscope system aiming for wide clinical use. From the results of in vitro tests using a mock circulation system, it was confirmed that the newly designed system was capable of visualizing a target installed on an inner surface of the mock system suggesting an availability of the system for an aortoscope without blocking off aortic flow.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2012 (1094687X) , 5765-5768
Development of a new aortoscope system for the use of endovascular intervention
“Balloon aortoscopy” is a technique for viewing inner wall of aorta and used in clinics [1, 2]. By this method, endoluminal aortic surface could be clearly monitored, however, during this period, the aortic blood flow is blocked off by the inflated balloon. To solve this clinical problem, we have been developing a prototype aortoscope system without blocking off aortic flow aiming for the use of an assistive technique for endovascular interventions such as stent-graft placement for aortic aneurysm and have been evaluating through in vitro and in vivo tests. The technique introduced for this purpose was the use of intermittent and instantaneous saline jet controlled by a high-speed electromagnetic valve synchronized to heart beat (diastolic phase). In the previous study, we designed an endoscope with two channels (one for saline discharge and the other for forceps insertion), and confirmed the validity of this method by in vitro and in vivo tests [3, 4]. Based on these findings, in this study, we have newly designed a conventional and low price endoscope system aiming for wide clinical use. From the results of in vitro tests using a mock circulation system, it was confirmed that the newly designed system was capable of visualizing a target installed on an inner surface of the mock system suggesting an availability of the system for an aortoscope without blocking off aortic flow.
- 17 September 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 54 (10) , 1892-1895
Accuracy Assessment of a Noninvasive Device for Monitoring Beat-by-Beat Blood Pressure in the Radial Artery Using the Volume-Compensation Method
For the noninvasive and accurate measurement of instantaneous blood pressure (BP) in the radial artery, the performance of a device based on the principle of volume-compensation was assessed by comparison with simultaneous measurement of direct (invasive) radial artery pressure in nine healthy subjects. Bias and precision of systolic BP (SBP) and diastolic BP (DBP) derived from Bland-Altman plots of data from the present system and the direct method averaged -0.5 plusmn 2.1 mmHg and 0.6 plusmn 1.8 mmHg respectively, over a wide range of SBP and DBP. These results clearly indicate that, using this system, instantaneous radial artery pressure can be measured noninvasively with high accuracy.
- 17 September 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 54 (10) , 1892-1895
Accuracy Assessment of a Noninvasive Device for Monitoring Beat-by-Beat Blood Pressure in the Radial Artery Using the Volume-Compensation Method
For the noninvasive and accurate measurement of instantaneous blood pressure (BP) in the radial artery, the performance of a device based on the principle of volume-compensation was assessed by comparison with simultaneous measurement of direct (invasive) radial artery pressure in nine healthy subjects. Bias and precision of systolic BP (SBP) and diastolic BP (DBP) derived from Bland-Altman plots of data from the present system and the direct method averaged -0.5 plusmn 2.1 mmHg and 0.6 plusmn 1.8 mmHg respectively, over a wide range of SBP and DBP. These results clearly indicate that, using this system, instantaneous radial artery pressure can be measured noninvasively with high accuracy.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2007 (1094687X) , 722-725
A Preliminary Study on Driver's Stress Index Using a New Method Based on Differential Skin Temperature Measurement
Prolonged periods of driving in monotonous situations may lower a driver's activation state as well as increasing their stress level due to the compulsion to maintain safe driving, which may result in an increased risk of a traffic accident. There is therefore an opportunity for technological assessment of driver physiological status to be applied in-car, hopefully reducing the incidence of potentially dangerous situations. As part of our long-term aim to develop such a system, we describe here the investigation of differential skin temperature measurement as a possible marker of a driver's stress level. 10 healthy male subjects were studied, under environment-controlled conditions, whilst being subjected to simulated monotonous travel at constant speed on a test-course. We acquired measurements of relevant physiological variables, including truncal and peripheral skin temperatures (Ts), beat-by-beat blood pressure (BP), cardiac output (CO), total peripheral resistance (TPR), and normalized pulse volume (NPV) used as an indicator of local peripheral vascular tone. We then investigated the driver's reactivity in terms of cardiovascular haemodynamics and skin temperatures. We found that the simulated monotonous driving produced a gradual drop in peripheral Ts following the driving stress, which, through interpretation of the TPR and NPV recordings, could be explained by peripheral sympathetic activation. On the other hand, the truncal Ts was not influenced by the stress. These findings lead us to suggest that truncal-peripheral differential Ts might be used as a possible index indicative of the driver's stress. Such an index, if decisively validated, would be easy to apply in real driving situations by using radiation thermometer.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2007 (1094687X) , 722-725
A Preliminary Study on Driver's Stress Index Using a New Method Based on Differential Skin Temperature Measurement
Prolonged periods of driving in monotonous situations may lower a driver's activation state as well as increasing their stress level due to the compulsion to maintain safe driving, which may result in an increased risk of a traffic accident. There is therefore an opportunity for technological assessment of driver physiological status to be applied in-car, hopefully reducing the incidence of potentially dangerous situations. As part of our long-term aim to develop such a system, we describe here the investigation of differential skin temperature measurement as a possible marker of a driver's stress level. 10 healthy male subjects were studied, under environment-controlled conditions, whilst being subjected to simulated monotonous travel at constant speed on a test-course. We acquired measurements of relevant physiological variables, including truncal and peripheral skin temperatures (Ts), beat-by-beat blood pressure (BP), cardiac output (CO), total peripheral resistance (TPR), and normalized pulse volume (NPV) used as an indicator of local peripheral vascular tone. We then investigated the driver's reactivity in terms of cardiovascular haemodynamics and skin temperatures. We found that the simulated monotonous driving produced a gradual drop in peripheral Ts following the driving stress, which, through interpretation of the TPR and NPV recordings, could be explained by peripheral sympathetic activation. On the other hand, the truncal Ts was not influenced by the stress. These findings lead us to suggest that truncal-peripheral differential Ts might be used as a possible index indicative of the driver's stress. Such an index, if decisively validated, would be easy to apply in real driving situations by using radiation thermometer.
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 5129-5132
Hemodynamic Responses during Simulated Automobile Driving in a Monotonous Situation
Long hours of automobile driving under monotonous situations may cause the lowering of what we term a driver's activation state (DAS) or in other words the production of drowsiness, resulting in an increased risk of a traffic accident. There is therefore a need to create a newly advanced system focused on the DAS in-car, hopefully thus avoiding potentially dangerous situations. In order to develop such a system as a final goal, we have firstly set out to acquire such cardiovascular variables as beat-by-beat blood pressure (BP), RR interval from ECG and normalized pulse volume (NPV) used as a peripheral vascular tone of alpha-adrenergic sympathetic activity, during presentation to the driver of a screen movie simulating monotonous travel at constant speed on a test-course. Subsequently, we have investigated the reactivity in terms of the driver's cardiovascular hemodynamics. Through the successful monitoring of cardiovascular parameters during the movie presentation obtained in 11 healthy male subjects, the following results were obtained: The monotonous driving produces a statistically significant gradual rise in BP following drowsiness, which could be explained by enhancement of sympathetic activity using a time-frequency analysis of BP and RR. This finding strongly indicates that continuous driving in such monotonous situations can make a driver considerably stressful and thus may cause a gradual increase in BP, and that this gradual BP increase may be used as a possible index relevant to the DAS. This finding was also confirmed by the analysis of NPV, suggesting that the gradual increase in BP during the monotonous driving would be rather caused by a regulation of peripheral vasomotor constriction
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 5129-5132
Hemodynamic Responses during Simulated Automobile Driving in a Monotonous Situation
Long hours of automobile driving under monotonous situations may cause the lowering of what we term a driver's activation state (DAS) or in other words the production of drowsiness, resulting in an increased risk of a traffic accident. There is therefore a need to create a newly advanced system focused on the DAS in-car, hopefully thus avoiding potentially dangerous situations. In order to develop such a system as a final goal, we have firstly set out to acquire such cardiovascular variables as beat-by-beat blood pressure (BP), RR interval from ECG and normalized pulse volume (NPV) used as a peripheral vascular tone of alpha-adrenergic sympathetic activity, during presentation to the driver of a screen movie simulating monotonous travel at constant speed on a test-course. Subsequently, we have investigated the reactivity in terms of the driver's cardiovascular hemodynamics. Through the successful monitoring of cardiovascular parameters during the movie presentation obtained in 11 healthy male subjects, the following results were obtained: The monotonous driving produces a statistically significant gradual rise in BP following drowsiness, which could be explained by enhancement of sympathetic activity using a time-frequency analysis of BP and RR. This finding strongly indicates that continuous driving in such monotonous situations can make a driver considerably stressful and thus may cause a gradual increase in BP, and that this gradual BP increase may be used as a possible index relevant to the DAS. This finding was also confirmed by the analysis of NPV, suggesting that the gradual increase in BP during the monotonous driving would be rather caused by a regulation of peripheral vasomotor constriction
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 5129-5132
Hemodynamic Responses during Simulated Automobile Driving in a Monotonous Situation
Long hours of automobile driving under monotonous situations may cause the lowering of what we term a driver's activation state (DAS) or in other words the production of drowsiness, resulting in an increased risk of a traffic accident. There is therefore a need to create a newly advanced system focused on the DAS in-car, hopefully thus avoiding potentially dangerous situations. In order to develop such a system as a final goal, we have firstly set out to acquire such cardiovascular variables as beat-by-beat blood pressure (BP), RR interval from ECG and normalized pulse volume (NPV) used as a peripheral vascular tone of alpha-adrenergic sympathetic activity, during presentation to the driver of a screen movie simulating monotonous travel at constant speed on a test-course. Subsequently, we have investigated the reactivity in terms of the driver's cardiovascular hemodynamics. Through the successful monitoring of cardiovascular parameters during the movie presentation obtained in 11 healthy male subjects, the following results were obtained: The monotonous driving produces a statistically significant gradual rise in BP following drowsiness, which could be explained by enhancement of sympathetic activity using a time-frequency analysis of BP and RR. This finding strongly indicates that continuous driving in such monotonous situations can make a driver considerably stressful and thus may cause a gradual increase in BP, and that this gradual BP increase may be used as a possible index relevant to the DAS. This finding was also confirmed by the analysis of NPV, suggesting that the gradual increase in BP during the monotonous driving would be rather caused by a regulation of peripheral vasomotor constriction
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 5129-5132
Hemodynamic Responses during Simulated Automobile Driving in a Monotonous Situation
Long hours of automobile driving under monotonous situations may cause the lowering of what we term a driver's activation state (DAS) or in other words the production of drowsiness, resulting in an increased risk of a traffic accident. There is therefore a need to create a newly advanced system focused on the DAS in-car, hopefully thus avoiding potentially dangerous situations. In order to develop such a system as a final goal, we have firstly set out to acquire such cardiovascular variables as beat-by-beat blood pressure (BP), RR interval from ECG and normalized pulse volume (NPV) used as a peripheral vascular tone of alpha-adrenergic sympathetic activity, during presentation to the driver of a screen movie simulating monotonous travel at constant speed on a test-course. Subsequently, we have investigated the reactivity in terms of the driver's cardiovascular hemodynamics. Through the successful monitoring of cardiovascular parameters during the movie presentation obtained in 11 healthy male subjects, the following results were obtained: The monotonous driving produces a statistically significant gradual rise in BP following drowsiness, which could be explained by enhancement of sympathetic activity using a time-frequency analysis of BP and RR. This finding strongly indicates that continuous driving in such monotonous situations can make a driver considerably stressful and thus may cause a gradual increase in BP, and that this gradual BP increase may be used as a possible index relevant to the DAS. This finding was also confirmed by the analysis of NPV, suggesting that the gradual increase in BP during the monotonous driving would be rather caused by a regulation of peripheral vasomotor constriction
- 11 July 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Engineering in Medicine and Biology Magazine
- Vol. 24 (4) , 32-37
Noninvasive measurement of instantaneous, radial artery blood pressure
A new prototype system for the noninvasive measurement of instantaneous blood pressure (BP) in the human radial artery has been developed. The system is based on the volume-compensation method, but several components were newly designed, namely, a disk-type cuff for local pressurization and a nozzle-flapper-type electro-pneumatic converter (EPC) for the cuff-pressure control. Results of experiments indicated that, using the disk-type cuff, the radial artery could be completely compressed, and the newly devised EPC had sufficient frequency response for BP measurement in humans. It was also found that the prototype system comprising these components was capable of noninvasively measuring instantaneous BP in the human radial artery, not only under rest conditions but also in a stressful condition, such as during the cold pressor test. In conclusion, the newly developed local pressurization technique appears promising as a useful and helpful means for instantaneous BP monitoring over longer periods of time than have previously been possible. Using this method, it is possible to construct an instrument that is more compact and more comfortable for the subject to use than a conventional commercial instrument. Finally, it has been reported that it may be possible to monitor cardiac output continuously by BP waveform analysis. Thus, continuous cardiac output monitoring might be another potential and important application of the newly designed instrument.
- 11 July 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Engineering in Medicine and Biology Magazine
- Vol. 24 (4) , 32-37
Noninvasive measurement of instantaneous, radial artery blood pressure
A new prototype system for the noninvasive measurement of instantaneous blood pressure (BP) in the human radial artery has been developed. The system is based on the volume-compensation method, but several components were newly designed, namely, a disk-type cuff for local pressurization and a nozzle-flapper-type electro-pneumatic converter (EPC) for the cuff-pressure control. Results of experiments indicated that, using the disk-type cuff, the radial artery could be completely compressed, and the newly devised EPC had sufficient frequency response for BP measurement in humans. It was also found that the prototype system comprising these components was capable of noninvasively measuring instantaneous BP in the human radial artery, not only under rest conditions but also in a stressful condition, such as during the cold pressor test. In conclusion, the newly developed local pressurization technique appears promising as a useful and helpful means for instantaneous BP monitoring over longer periods of time than have previously been possible. Using this method, it is possible to construct an instrument that is more compact and more comfortable for the subject to use than a conventional commercial instrument. Finally, it has been reported that it may be possible to monitor cardiac output continuously by BP waveform analysis. Thus, continuous cardiac output monitoring might be another potential and important application of the newly designed instrument.
- 1 January 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2005 (1094687X) , 3939-3941
Fully Automatic System for Monitoring Blood Pressure from a Toilet-Seat Using the Volume-Oscillometric Method
Daily monitoring of health condition at home is very important subject not only as an effective scheme for early diagnosis and treatment of cardiovascular and other diseases, but also for prevention and control of such diseases. From this point of view, we have been developing a fully automated "non-conscious" monitoring system for home health care. In this paper are described, structural detail of a newly developed toilet-seat-installed blood pressure measurement system and some results obtained by the system. Also described is outline of a newly designed system for measuring hydrostatic pressure difference between the heart and the measuring site, i.e., thigh, during blood pressure measurement
- 1 January 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2005 (1094687X) , 3939-3941
Fully Automatic System for Monitoring Blood Pressure from a Toilet-Seat Using the Volume-Oscillometric Method
Daily monitoring of health condition at home is very important subject not only as an effective scheme for early diagnosis and treatment of cardiovascular and other diseases, but also for prevention and control of such diseases. From this point of view, we have been developing a fully automated "non-conscious" monitoring system for home health care. In this paper are described, structural detail of a newly developed toilet-seat-installed blood pressure measurement system and some results obtained by the system. Also described is outline of a newly designed system for measuring hydrostatic pressure difference between the heart and the measuring site, i.e., thigh, during blood pressure measurement