Abstract
High quality factor and sensitivity are critical to wireless sensors targeting small perturbation detection. Although introducing parity-time symmetric dynamics promises enhanced performance, the symmetric scheme often yields limited sensing behaviors. In particular, its implementation is hindered by the inherent difficulties in decoupling capacitance- and coupling strength–induced responses, the requirements of delicately matching and/or tuning both gain and loss, and the need of strong coupling strength. Here, we report a concept of critical point (CP)–based wireless sensors that do not rely on balanced gain-loss configurations, delivering ultrahigh quality factor with an extended interrogation distance. Owing to a sharp and deep reflection dip, the CP-based scheme can resolve the change in coupling coefficient down to 1.92 × 10 −4 and features frequency-independent responses. Furthermore, the CP-based scheme allows for identification of tiny asymmetric capacitive perturbations as small as 2.5 × 10 −5 without requiring active tuning of the other parameters under weak coupling.
Funding Information
  • National Natural Science Foundation of China (62304011)
  • National Natural Science Foundation of China (52577015)
  • China Postdoctoral Science Foundation (2022TQ0003)
  • National Key Research and Development Program of China (2021YFA1202904)
  • National Key Research and Development Program of China (2022YFB4401603)
  • Shaanxi Province Key Research and Development Program (2024GX-YBXM-236)

This publication has 58 references indexed in Scilit: