CMChao Ma

Chao Ma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Chao Ma has a total of 53 co-authors. Here are the top co-authors by number of shared publications:

  • Youfan Hu

    Key Laboratory for the Physics and Chemistry of Nanodevices, Center for Carbon-Based Electronics and School of Electronics, Peking University, Beijing 100871, China

    4 shared publications
  • Tian Xia

    Key Laboratory for the Physics and Chemistry of Nanodevices and School of Electronics and Center for Carbon-Based Electronics, Peking University, Beijing 100871, China

    3 shared publications
  • Tianyu Dong

    School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China

    3 shared publications
  • Yufan Chen

    Key Laboratory for the Physics and Chemistry of Nanodevices and School of Electronics and Center for Carbon-Based Electronics, Peking University, Beijing 100871, China

    3 shared publications
  • Fan Xia

    Key Laboratory for the Physics and Chemistry of Nanodevices and School of Electronics and Center for Carbon-Based Electronics, Peking University, Beijing 100871, China

    2 shared publications
  • Ke Yin

    Sichuan University

    2 shared publications

Latest Publications

  • Open Access

    Critical point–based wireless sensors enabling tiny perturbation detection

    by Chao Ma, Ke Yin, Zhuoyu Zhang, Ruyi Huang, Yuangen Huang, Lanyue Gan, Yuxuan Liu, Fan Xia, Tian Xia, Yufan Chen, et al.

    High quality factor and sensitivity are critical to wireless sensors targeting small perturbation detection. Although introducing parity-time symmetric dynamics promises enhanced performance, the symmetric scheme often yields limited sensing behaviors. In particular, its implementation is hindered by the inherent difficulties in decoupling capacitance- and coupling strength–induced responses, the requirements of delicately matching and/or tuning both gain and loss, and the need of strong coupling strength. Here, we report a concept of critical point (CP)–based wireless sensors that do not rely on balanced gain-loss configurations, delivering ultrahigh quality factor with an extended interrogation distance. Owing to a sharp and deep reflection dip, the CP-based scheme can resolve the change in coupling coefficient down to 1.92 × 10 −4 and features frequency-independent responses. Furthermore, the CP-based scheme allows for identification of tiny asymmetric capacitive perturbations as small as 2.5 × 10 −5 without requiring active tuning of the other parameters under weak coupling.

  • Flexible radio-frequency carbon nanotube transistors operating at frequencies above 100 GHz

    by Fan Xia, Tian Xia, Haotian Su, Lanyue Gan, Qianlan Hu, Wanyi Wang, Ruyi Huang, Tianshun Bai, Yufan Chen, Chao Ma, et al.


  • High-Performance Integrated Pressure Sensors via Microstructured Electrodes Coupled With Floating-Gate CNT Transistors

    by Chao Ma, Yufan Chen, Yulong Yuan, Tian Xia, Huaidong Ye, Wangchang Li, Youfan Hu

    Transistor-integrated flexible pressure sensors have received considerable interest in emerging fields such as humanoid robotics, prosthetics, and implantable electronics. However, existing designs for these integrated sensors often exhibit a trade-off between pressure response and operating voltage, thus significantly limiting their practical applications. In this letter, we report a unique device design of integrated pressure sensors based on deformable microstructured electrodes capacitively coupled with floating-gate carbon nanotube transistors. The microstructured electrodes can dramatically enhance the pressure-introduced electrostatic control of the transistor, enabling a substantial improvement in the transduced pressure response at low operating voltages. With this unique design, we achieve a high pressure response of 105 and an ultrahigh sensitivity up to 104 kPa-1 at a low operating voltage below 3 V, which holds great promise for the development of advanced functionalized flexible electronics.


  • A wearable system for sign language recognition enabled by a convolutional neural network

    by Yuxuan Liu, Xijun Jiang, Xingge Yu, Huaidong Ye, Chao Ma, Wanyi Wang, Youfan Hu


  • Wireless real-time capacitance readout based on perturbed nonlinear parity-time symmetry

    by Ke Yin, Yuangen Huang, Chao Ma, Xianglin Hao, Xiaoke Gao, Xikui Ma, Tianyu Dong

    In this article, we report a vector-network-analyzer-free and real-time LC wireless capacitance readout system based on perturbed nonlinear parity-time (PT) symmetry. The system is composed of two inductively coupled reader-sensor parallel RLC resonators with gain and loss, respectively. By searching for the real mode that requires the minimum saturation gain, the steady-state frequency evolution as a function of the sensor capacitance perturbation is analytically deduced. The proposed system can work in different modes by setting different perturbation points. In particular, at the exceptional point of PT symmetry, the system exhibits high sensitivity. Experimental demonstrations revealed the viability of the proposed readout mechanism by measuring the steady-state frequency of the reader resonator in response to the change of trimmer capacitor on the sensor side. Our findings could impact many emerging applications such as implantable medical device for health monitoring, parameter detection in harsh environment, sealed food packages, etc.


  • Open Access

    Mould-Free Skin-Inspired Robust and Sensitive Flexible Pressure Sensors With Hierarchical Microstructures

    by Chao Ma, Dong Xu, Wenfeng Liu, Tianyu Dong, Sheng-Tao Li

    Flexible microscopic pressure sensors are important to the emerging fields of intelligent robots and advanced healthcare. However, common microstructured pressure sensors often require sophisticated mould and/or material preparation, and yield limited pressure sensing performances. In this letter, we report a facile approach to design a scalable and stretchable mould-free sensitive layer with a unique hierarchical microstructure. Inspired by natural skin, a sensitive layer with interdigitated electrodes is utilized to constructed into resistive pressure sensors, which are able to robustly detect the pressure variations with high sensitivity in a wide dynamic range (about 33 kPa-1 below 5 kPa, more than 0.6 kPa-1 under 108 kPa), also deliver low hysteresis (within 8%), rapid response (less than 48 ms), and ultralow operation voltage (10 μV). We illustrate that such self-patterned high-performance pressure sensors can be applied to convert the pressure stimulus into spike-like signals in both low- and medium-pressure regimes, and are being able to clearly reveal the details of human pulse wave.


  • Robust Flexible Pressure Sensors Made from Conductive Micropyramids for Manipulation Tasks

    by Chao Ma, Dong Xu, Yun-Chiao Huang, Peiqi Wang, Jin Huang, Jingyuan Zhou, Wenfeng Liu, Sheng-Tao Li, Yu Huang, Xiangfeng Duan

    Flexible pressure sensors that can robustly mimic the function of slow-adapting type I (SA-I) mechanoreceptors are essential for realizing human-like object manipulation in artificial intelligent (AI) robots or amputees. Here, we report a straightforward approach to highly sensitive and robust flexible pressure sensors with fast response time and low operating voltage based on conductive micropyramids made of polydimethylsiloxane/carbon nanotube composites. Both numerical simulations and experimental studies show that the pressure-sensing properties of the devices can be systematically tuned by the spatial arrangement of micropyramids. In particular, by tailoring the ratio between the spacing and the pyramidal base length, the optimal pressure sensors can be achieved with a combination of high sensitivity in both low-pressure (<10 kPa) and medium-pressure (10–100 kPa) regimes, rapid response, high mechanical robustness, low operating voltage, and low power consumption, along with linear response and low hysteresis in the medium-pressure regimes. The optimized pressure sensor is further used for constructing a wearable pressure-sensing system that can convert the amplitude of pressure to wirelessly transmittable frequency signals (spikes) with nearly linear response, closely mimicking SA-I mechanoreceptors. Furthermore, we demonstrate that the high uniformity and scalability of the pressure sensors enable large-area pressure-sensing arrays for spatially resolved pressure mapping.


  • Sensitive pressure sensors based on conductive microstructured air-gap gates and two-dimensional semiconductor transistors

    by Yun-Chiao Huang, Yuan Liu, Chao Ma, Hung-Chieh Cheng, Qiyuan He, Hao Wu, Chen Wang, Cheng-Yi Lin, Yu Huang, Xiangfeng Duan


  • Trap distribution and direct current breakdown characteristics in polypropylene/Al2O3 nanodielectrics

    by Ma Chao, Min Dao-Min, Li Sheng-Tao, Zheng Xu, Li Xi-Yu, Min Chao, Zhan Hai-Xia

    Polypropylene (PP) is widely used as capacitor films due to its better dielectric, mechanical, and thermal performance. In order to reduce the cost and size of capacitor, high energy density for PP dielectric is pursued. Since energy density is in quadratic proportion to direct current (dc) breakdown strength for linear dielectric, the enhancement of dc breakdown strength for PP dielectric is a primary choice to improve the energy density. Considering that the incorporation of nano-Al2O3 is an effective method to improve the dc breakdown strength for polymer, it is required to study the dc breakdown strength of PP/Al2O3 nanodielectric. In order to explore the breakdown mechanism, PP/Al2O3 nanodielectrics with different nano-particle contents are prepared by melt blending, and the samples are prepared by hot pressing. Their microstructures are observed by scanning electron microscopic. Isothermal surface potential decay, bulk resistivity, and dc breakdown strength of the samples are also measured. The experimental results show that the energy and density of deep traps, bulk resistivity, and dc breakdown strength first increase and then decrease with the increase in nano-Al2O3 content. The maximum values are obtained at a filer content value of 0.5 wt%, where dc breakdown strength can be increased by about 27%. Based on interface model, the relation between microstructure and trap is investigated. In view of space charge breakdown theory, the mechanism of dc breakdown for PP/Al2O3 nanodielectric is explored by trap parameters. It is indicated that the interface can provide more deep traps in PP/Al2O3 nanodielectric, while the decrease in the energy and density of deep traps can be attributed to the overlap of interfaces in electrical double layer. The increase in the energy and density of deep traps makes more carriers trapped near the injecting contact, thus reducing the effective field for carrier injection due to the internal field generated by the trapped carriers. The reduction of carrier injection can moderate the distortion of field in PP dielectric, consequently, resulting in enhancing the dc breakdown strength.