Influence of Luting Materials on the Retention of Cemented Implant-Supported Crowns: An In Vitro Study
Open Access
- 28 September 2018
- Vol. 11 (10) , 1853
Abstract
The retention force of cemented crowns on implant abutments with various luting materials was evaluated. Cobalt–chromium crowns were cemented onto tapered titanium abutments (Camlog) with eugenol-free temporary cement (RelyX TempBond NE), composite-based temporary cement (Bifix Temp), zinc phosphate cement (Harvard Cement), glass-ionomer cements (Meron, Fuji I), and resin-modified glass-ionomer cements (Fuji II, Fuji Plus, Ketac Cem Plus). Specimen aging via hydrostress was performed in artificial saliva at 37 °C for 14 days (S1), followed by hydrothermal stress with thermocycling (S2). The crowns were removed, and the force was recorded (T1). Subsequently, the crowns were recemented, aged, and removed, and the force was recorded (T2, T3). The retention forces differences were statistically significant according to the storage conditions at T1 (p = 0.002) and T3 (p = 0.0002). After aging (S1), Ketac Cem Plus had the highest retention force median value difference (T3 versus T1) (−773 N), whereas RelyX TempBond NE had the lowest (−146 N). After aging (S2), Meron had the highest retention force median value difference (−783 N), whereas RelyX TempBond NE had the lowest (−168 N). Recementation decreased the retention force of the implant-supported cobalt–chromium crowns cemented and recemented with the same luting materials. Luting materials (at T1) and aging conditions significantly impacted the retention force.Keywords
This publication has 48 references indexed in Scilit:
- Luting Agent Effectiveness on Implant Crown RetentionInternational Journal of Oral Implantology and Clinical Research, 2011
- Prosthetic outcome of cement‐retained implant‐supported fixed dental restorations: a systematic reviewJournal of Oral Rehabilitation, 2011
- Retention force of secondary crowns to copings after temporary cementation: the effect of crown material and luting agentBiomedical Engineering / Biomedizinische Technik, 2010
- Retention of cast crown copings cemented to implant abutmentsAustralian Dental Journal, 2008
- Retrievability of implant‐retained crowns following cementationClinical Oral Implants Research, 2008
- Biological basis for soft tissue management in implant dentistryAustralian Dental Journal, 2008
- Cement Selection for Cement‐Retained Crown Technique with Dental ImplantsJournal of Prosthodontics, 2007
- Exploration of ductile, brittle failure characteristics through a two-parameter yield/failure criterionMaterials Science and Engineering: A, 2005
- A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 yearsClinical Oral Implants Research, 2004
- The effects of abutment taper, length and cement type on resistance to dislodgement of cement‐retained, implant‐supported restorationsJournal of Prosthodontics, 2003