APAndree Piwowarczyk

Andree Piwowarczyk

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andree Piwowarczyk has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparison of Vertical Measurements Between Panoramic Radiograph Images and Corresponding Cone-Beam Computed Tomography Scans

    by Ali-Reza Ketabi, Stefan Hassfeld, Laurentia Schuster, Sandra Ketabi, Julius Stueben, Andree Piwowarczyk

    Background: This study analysed whether vertical measurements in the maxillary posterior region are more accurate using panoramic radiography (PAN) or cone-beam computed tomography (CBCT). Methods: Corresponding maxillary posterior regions on both PAN and CBCT images were selected and examined for vertical measurements. The vertical distance between the bone crest and the floor of the maxillary sinus was measured. Measurements in edentulous regions were performed using a similar procedure. Additionally, the vertical height of any defect, if present, was measured. Results were evaluated statistically. Results: When comparing corresponding regions on the CBCT and PAN images, 204 patients with a total of 341 measurements (n = 341) met the inclusion criteria. The mean values for all measurements were 7.21 ± 3.74 mm on PAN and 7.62 ± 4.06 mm on CBCT. The mean difference between all paired measurements was −0.41 ± 1.03 mm. Significant differences between PAN and CBCT were observed (p < 0.001). Defects were detected in 58 (17%) of the 341 measurements. The mean defect height was 1.85 ± 1.05 mm on PAN and 1.99 ± 1.00 mm on CBCT. No significant differences were noted between PAN and CBCT (p = 0.052). Conclusions: Although the relationship between vertical height measurements on PAN and CBCT showed a significant difference of −0.41 ± 1.03 mm for all paired measurements, the difference was very small upon closer inspection. Both PAN and CBCT are suitable methods for measuring vertical heights in the posterior maxilla.


  • Open Access

    Comparative diagnosis of the alveolar antral artery canal in the lateral maxillary sinus wall in corresponding panoramic radiography and cone-beam computed tomography

    by Ali-Reza Ketabi, Stefan Hassfeld, Hans-Christoph Lauer, Andree Piwowarczyk

    Purpose: Sinus lift operations are a tried and tested means of providing adequate implant prosthetics to patients with compromised jawbones. Knowledge of the arterial supply of the maxillary sinus region is essential for surgical treatment in this area. The aim of the present comparative study was to determine whether alveolar antral artery (AAA) canal can be diagnosed both in corresponding panoramic radiography (PR) and cone-beam computed tomography (CBCT). Methods: A total of 335 patients with 635 sites and corresponding maxillary sinus in both PR and CBCT were selected and examined for AAA canal visibility. Results: The visibility of the AAA canal was significantly higher in CBCT than in PR. A total of 154 (46.0%) AAA canals could be identified in the maxillary sinus on the right. However, only four (1.2%) of these were also visible in PR. The detected values of the AAA canals in the maxillary sinus on the left in the PR and CBCT images were similar to those of the right. While 164 AAA canals (49%) were observed in CBCT images, only 1 (0.3%) was identifiable in PR. Conclusions: The results show that CBCT can be recommended for visualising the AAA canal when surgically planning sinus augmentation procedures. Graphical


  • Open Access

    Human Gingival Fibroblast Adhesion and Proliferation on Hydroxyapatite-Coated Zirconia Abutment Surfaces

    by Oskar Bunz, Marie-Christine Steegmann, Korbinian Benz, Holger Testrich, Antje Quade, Ella A. Naumova, Wolfgang H. Arnold, Katja Fricke, Andree Piwowarczyk, Thomas Dittmar

    Applying antibacterial coatings to dental implant materials seems reasonable but can have negative influences on desired cell adhesion and healing. In this study, zirconia abutment specimens interacting with gingival tissue were used. The aim was to compare the influence of machined or coated zirconia surfaces on the adhesion and proliferation of human gingival fibroblasts (HGF-1). Surface modifications were performed using atmospheric plasma coating with hydroxyapatite, zinc, and copper. Zirconia specimens were divided into four groups: hydroxyapatite, hydroxyapatite with zinc oxide (ZnO), hydroxyapatite with copper (Cu), and an untreated machined surface. After the characterization of the surface conditions, the morphology of adhered HGF-1 was determined by fluorescence staining and subjected to statistical evaluation. The visual analysis of cell morphology by SEM showed flat, polygonal, and largely adherent fibroblast cells in the untreated group, while round to partially flat cells were recorded in the groups with hydroxyapatite, hydroxyapatite + ZnO, and hydroxyapatite + Cu. The cell membranes in the hydroxyapatite + ZnO and hydroxyapatite + Cu groups appeared porous. The results show that HGF-1 adhere and proliferate well on machined zirconia, while plasma coating with hydroxyapatite or hydroxyapatite mixtures does not lead to increased adhesion or proliferation.


  • Open Access

    Survival of Fiber-Reinforced Composite Resin Post-Restored vs. Cast Post-and-Core-Restored Teeth: A Retrospective Clinical Study

    by Oskar Bunz, Darja Iwantschenko, Sabrina Tulka, Claudia Barthel-Zimmer, Andree Piwowarczyk

    Objective: The question of whether classic cast post-and-core (CPC) or fiber-reinforced composite resin posts (FRCP) are the best clinical decision has still not been fully solved. Materials and Methods: One hundred and sixty-two teeth were restored with FRCP, and 162 CPC restored teeth were included in this study with a matched-pair design. In a primary analysis, the survival rates after one year (primary endpoint) were compared. The additional analysis included an evaluation of tooth- and construction-specific variables and an illustration of the survival up to 60 months via Kaplan-Meier curves. Results: FRCP showed lower failure risk considering the definitive prosthetic restoration and tooth type compared to CPC restored teeth. In total, 17 failures were observed in the FRCP group and 35 failures in the CPC group. A 60-month survival rate of 79.3% for FRCP and 64.5% for CPC was observed. Teeth serving as abutments for telescopic dentures were more likely to be affected by failure compared to teeth restored with single crowns. Conclusion: Within the limitations of this study, the FRCP showed a lower failure risk compared to the CPC, considering the definitive prosthetic restoration and tooth type within the observation period.


  • Open Access

    Cold Atmospheric Plasma Improves Shear Bond Strength of Veneering Composite to Zirconia

    by Oskar Bunz, Paul Kalz, Carla I. Benz, Ella A. Naumova, Wolfgang H. Arnold, Andree Piwowarczyk

    Chipping of veneering is the most common clinical complication for zirconia restorations. Veneering composite could be a promising alternative to renew restorations. Zirconia discs (3-YSZ) were prepared with varying surface treatments and bonded to indirect composite as follows: air abrasion and Scotchbond Universal (A/SU); air abrasion and Clearfil Ceramic Primer (A/C); air abrasion and MKZ Primer (A/M); air abrasion and Monobond Plus (A/MP); silica-coating and Scotchbond Universal (S/SU); air abrasion (AP/SU), additional cold atmospheric plasma treatment, and Scotchbond Universal. An indirect composite material was then applied to the zirconia specimens. Specimens were divided into subgroups for short-term (14 days storage at 37 °C and 5000 thermal cycles) and long-term (250 days storage and 37,500 thermal cycles) artificial aging. Shear bond strength measurement (SBS) was performed, and data were analyzed by Kruskal–Wallis-test and multiple comparison testing with Dunn’s correction (p ≤ 0.05). The median SBS values (MPa) of short- and long-term artificial aging were: 3.09/1.36 (A/SU); 0.77/1.43 (S/SU); 2.82/2.15 (AP/SU); 1.97/1.80 (A/C); 2.01/1.58 (A/M); and 1.70/1.68 (A/MP). For short-term artificial aging A/SU showed the highest median SBS values, whereas in the long-term trial, AP/SU showed the highest values and the difference was significant. A prolonged artificial aging decreased SBS in all groups, except S/SU. In summary, treatment with CAP can improve SBS in the long-term.


  • Open Access

    Low-Pressure Plasma Sterilization for Test Specimens to be Worn on Splints in the Oral Cavity

    by Ella A. Naumova, Alexander-Simon Engel, Hagen Tizian Kranz, Marvin Schneider, Jan Tietze, Thomas Dittmar, Marcel Fiebrandt, Katharina Stapelmann, Andree Piwowarczyk, Thorsten Kuczius, et al.

    Bacterial biofilms adhere to all oral surfaces and may alter or degrade them. For investigations of the oral biofilm, growing on new restorative dental biomaterials, sterilized dental enamel surfaces as natural, control, and reference materials are used. A novel method for disinfection and sterilization of surfaces is low-pressure plasma (LPP) sterilization, which is a nondestructive and nontoxic technology. The roughness of the dental enamel surface was determined before and after LPP sterilization. Enamel discs were placed in dental splints and worn for five days in vivo. Oral biofilm was fixed for scanning electron microscopy (SEM). Biofilms growing in vitro were characterized microbiologically before and after sterilization and examined by confocal laser scanning microscopy (CLSM). Microbiology demonstrated that various bacterial strains were present in the biofilms. SEM showed multiple layers of densely packed bacteria, and CLSM demonstrated that the biofilm contained live and dead bacteria. After LPP sterilization, no biofilm could be detected, and the enamel surface remained unaltered. It may be concluded that LPP sterilization is an effective, nondestructive method for disinfection of enamel before application in the oral cavity. LPP sterilization may be suitable for sterilization of dental materials without altering their surfaces.


  • Open Access

    Influence of Luting Materials on the Retention of Cemented Implant-Supported Crowns: An In Vitro Study

    by Ella A. Naumova, Felix Roth, Berit Geis, Christine Baulig, Wolfgang H. Arnold, Andree Piwowarczyk

    The retention force of cemented crowns on implant abutments with various luting materials was evaluated. Cobalt–chromium crowns were cemented onto tapered titanium abutments (Camlog) with eugenol-free temporary cement (RelyX TempBond NE), composite-based temporary cement (Bifix Temp), zinc phosphate cement (Harvard Cement), glass-ionomer cements (Meron, Fuji I), and resin-modified glass-ionomer cements (Fuji II, Fuji Plus, Ketac Cem Plus). Specimen aging via hydrostress was performed in artificial saliva at 37 °C for 14 days (S1), followed by hydrothermal stress with thermocycling (S2). The crowns were removed, and the force was recorded (T1). Subsequently, the crowns were recemented, aged, and removed, and the force was recorded (T2, T3). The retention forces differences were statistically significant according to the storage conditions at T1 (p = 0.002) and T3 (p = 0.0002). After aging (S1), Ketac Cem Plus had the highest retention force median value difference (T3 versus T1) (−773 N), whereas RelyX TempBond NE had the lowest (−146 N). After aging (S2), Meron had the highest retention force median value difference (−783 N), whereas RelyX TempBond NE had the lowest (−168 N). Recementation decreased the retention force of the implant-supported cobalt–chromium crowns cemented and recemented with the same luting materials. Luting materials (at T1) and aging conditions significantly impacted the retention force.


  • Open Access

    Polishing of Monolithic Zirconia Crowns—Results of Different Dental Practitioner Groups

    by Carla Kozmacs, Britta Hollmann, Wolfgang H. Arnold, Ella Naumova, Andree Piwowarczyk

    This pilot study evaluates the surface roughness of monolithic zirconia crowns after chairside polishing by different dental practitioner groups. Four practitioner groups (group I: dental clinical students (n = 6); group II: dentists < 2 years post-qualification experience (n = 6); group III: dentists > 2 years post-qualification experience (n = 6) and group IV: dental technicians (n = 6)) were asked to polish two CAD/CAM-fabricated full-contour zirconia crowns (48 in total). A two-step zirconia polishing kit was used in both trials. The first trial (T1) was conducted without a time limitation. In the second trial (T2), the polish was restricted to 15 seconds for each polisher. Two blinded investigators (I1 and I2) analyzed the surface roughness (Ra) before and after polishing (Alicona measuring system). No statistically significant difference in surface roughness was found between the polishing results of the dental practitioner groups. Major difference in surface finish was achieved by dental technicians, with a median value of 25.4 nm (interquartile range 10.15–35.26 nm) for I1 in T1. The lowest difference was achieved by dental students, with a median value of Ra = 6.72 nm (interquartile range 4.7–17.9 nm) in T1. In T2, experienced dentists showed the highest difference in surface finish, with a median value of 41.35 nm (interquartile range 7.77–54.11). No significant correlation was found between polishing time and polishing results. The polishing of monolithic zirconium dioxide crowns can be performed with the present polishing set directly chairside after occlusal adjustment, regardless of the practitioner’s experience level.


  • Open Access

    Wear Behavior of Ceramic CAD/CAM Crowns and Natural Antagonists

    by Ella A. Naumova, Stephan Schneider, Wolfgang H. Arnold, Andree Piwowarczyk

    Objective: Evaluation of wear behavior of computer-aided design/computer-aided manufacturing (CAD/CAM) crowns from various restorative materials and natural antagonists. Method: Full CAD/CAM crowns fabricated with nanoceramic resin (Lava Ultimate (LU)), a glass ceramic in a resin interpenetrating matrix (Vita Enamic (VE)) and a lithium silicate reinforced ceramic enriched with zirconia (Vita Suprinity (VS)) were cemented on human molars. The crown and antagonists were subjected to simulated chewing. 3D data sets, before and after the chewing simulation, were generated and matched. Occlusal surface roughness, vertical and volume loss of the crowns and antagonists were analyzed. Results: Crown roughness was significantly different between the LU and VE groups after chewing simulation. Crown vertical loss differed in all groups. The highest crown volume loss was found in the LU group, and the lowest in the VE group. Comparisons between the LU and VE groups and the LU and VS groups were significantly different. The highest antagonist volume loss was reached in the VE group, the lowest was in the LU group. Conclusion: Roughness increased after chewing simulation. LU crowns are the most natural antagonist-friendly; these were the most susceptible to vertical and volume loss. Of the tested materials, the VE crowns are the most stable regarding occlusion.