A novel computed method to reconstruct the bilateral digital interarticular channel of atlas and its use on the anterior upper cervical screw fixation
Authors:
Open Access
Abstract
Purpose.To investigate a novel computed method to reconstruct the bilateral digital interarticular channel of atlas and its potential use on the anterior upper cervical screw fixation.Methods.We have used the reverse engineering software (image-processing software and computer-aided design software) to create the approximate and optimal digital interarticular channel of atlas for 60 participants. Angles of channels, diameters of inscribed circles, long and short axes of ellipses were measured and recorded, and gender-specific analysis was also performed.Results.The channels provided sufficient space for one or two screws, and the parameters of channels are described. While the channels of females were smaller than that of males, no significant difference of angles between males and females were observed.Conclusion.Our study demonstrates the radiological features of approximate digital interarticular channels, optimal digital interarticular channels of atlas, and provides the reference trajectory of anterior transarticular screws and anterior occiput-to-axis screws. Additionally, we provide a protocol that can help make a pre-operative plan for accurate placement of anterior transarticular screws and anterior occiput-to-axis screws.Keywords
Funding Information
- National Natural Science Foundation of China (81372014, 81501933)
This publication has 18 references indexed in Scilit:
- The Accuracy of a Method for Printing Three-Dimensional Spinal ModelsPLOS ONE, 2015
- Percutaneous anterior occiput-to-axis screw fixation: technique aspects and case seriesThe Spine Journal, 2013
- The three-dimensional morphometry of the odontoid peg and its impact on ventral screw osteosynthesisThe Bone & Joint Journal, 2013
- Comparison of the anatomic risk for vertebral artery injury associated with percutaneous atlantoaxial anterior and posterior transarticular screwsThe Spine Journal, 2012
- Study of the Anatomical Variations of Vertebral Artery in C2 Vertebra With Magnetic Resonance Imaging and Its Application in the C1–C2 Transarticular Screw FixationSpine, 2010
- Percutaneous anterior transarticular screw fixation for atlantoaxial instabilityThe Journal of Bone and Joint Surgery. British volume, 2010
- A Novel Patient-Specific Navigational Template for Cervical Pedicle Screw PlacementSpine, 2009
- Lateral mass screw–rod fixation of the cervical spine: a prospective clinical series with 1-year follow-upThe Spine Journal, 2003
- Anterior Occiput-to-Axis Screw FixationSpine, 2003
- Posterior C1-C2 Transarticular Screw Fixation for Atlantoaxial ArthrodesisNeurosurgery, 1998