Yong-Long Chi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yong-Long Chi has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Ai-Min Wu
Department of Spinal Surgery, Second Affiliated Hospital of Wenzhou Medical University, The Key Orthopaedic Laboratory of Zhejiang Province , Wenzhou, Zhejiang , China
5 shared publicationsHua-Zi Xu
Department of Spinal Surgery, Second Affiliated Hospital of Wenzhou Medical University, The Key Orthopaedic Laboratory of Zhejiang Province , Wenzhou, Zhejiang , China
5 shared publicationsXiang-Yang Wang
Department of Spinal Surgery, Second Affiliated Hospital of Wenzhou Medical University, The Key Orthopaedic Laboratory of Zhejiang Province , Wenzhou, Zhejiang , China
4 shared publicationsNai-Feng Tian
Department of OrthopaedicsSecond Affiliated Hospital of Wenzhou Medical UniversityWenzhouZhejiangChina
3 shared publicationsXin-Dong Yang
Department of Anatomy, Wenzhou Medical University , Wenzhou , China
3 shared publicationsZhong-Ke Lin
Department of Spinal Surgery, Second Affiliated Hospital of Wenzhou Medical University, The Key Orthopaedic Laboratory of Zhejiang Province , Wenzhou, Zhejiang , China
3 shared publications
Latest Publications
- Open Access
- 29 September 2017
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 12 (1) , 1-8
Percutaneous anterior C1/2 transarticular screw fixation: salvage of failed percutaneous odontoid screw fixation for odontoid fracture
The objective of this study is to investigate the outcomes and safety of using percutaneous anterior C1/2 transarticular screw fixation as a salvage technique for odontoid fracture if percutaneous odontoid screw fixation fails. Fifteen in 108 odontoid fracture patients (planned to be treated by percutaneous anterior odontoid screw fixation) were failed to introduce satisfactory odontoid screw trajectory. To salvage this problem, we chose the percutaneous anterior C1/2 transarticular screw fixation technique in treatment of these patients. The visual analogue score (VAS) of neck pain and Neck Disability Index (NDI) of all patients were scored at pre-operation, 3 months after operation, and final follow-up. Additional, technique-related complications were recorded and collected. Percutaneous C1/2 transarticular screw fixation was performed successfully in all 15 patients whose odontoid screw fixation failed. No technique-related complications (such as nerve injury, spinal cord injury, and esophageal injury) occurred. The VAS of neck pain and NDI score improved significantly (P = 0.000) after operation, and no significant differences were found when compared to 93 non-salvage patients who successfully performed the percutaneous anterior odontoid screw fixation. No screw loose or breakage occurred, all of the odontoid fractures achieve radiographic fusion, bony fusion bridge could be observed at the C1/2 lateral articular facet on 9/15 patients. We suggest that percutaneous anterior C1/2 transarticular screw fixation is a good alternative salvage technique if percutaneous odontoid screw fixation failed, and it is a minimally invasive, feasible, and safe technique.
- 29 September 2017
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 12 (1) , 1-8
Open AccessPercutaneous anterior C1/2 transarticular screw fixation: salvage of failed percutaneous odontoid screw fixation for odontoid fracture
The objective of this study is to investigate the outcomes and safety of using percutaneous anterior C1/2 transarticular screw fixation as a salvage technique for odontoid fracture if percutaneous odontoid screw fixation fails. Fifteen in 108 odontoid fracture patients (planned to be treated by percutaneous anterior odontoid screw fixation) were failed to introduce satisfactory odontoid screw trajectory. To salvage this problem, we chose the percutaneous anterior C1/2 transarticular screw fixation technique in treatment of these patients. The visual analogue score (VAS) of neck pain and Neck Disability Index (NDI) of all patients were scored at pre-operation, 3 months after operation, and final follow-up. Additional, technique-related complications were recorded and collected. Percutaneous C1/2 transarticular screw fixation was performed successfully in all 15 patients whose odontoid screw fixation failed. No technique-related complications (such as nerve injury, spinal cord injury, and esophageal injury) occurred. The VAS of neck pain and NDI score improved significantly (P = 0.000) after operation, and no significant differences were found when compared to 93 non-salvage patients who successfully performed the percutaneous anterior odontoid screw fixation. No screw loose or breakage occurred, all of the odontoid fractures achieve radiographic fusion, bony fusion bridge could be observed at the C1/2 lateral articular facet on 9/15 patients. We suggest that percutaneous anterior C1/2 transarticular screw fixation is a good alternative salvage technique if percutaneous odontoid screw fixation failed, and it is a minimally invasive, feasible, and safe technique.
- Open Access
A novel computed method to reconstruct the bilateral digital interarticular channel of atlas and its use on the anterior upper cervical screw fixation
Purpose.To investigate a novel computed method to reconstruct the bilateral digital interarticular channel of atlas and its potential use on the anterior upper cervical screw fixation.Methods.We have used the reverse engineering software (image-processing software and computer-aided design software) to create the approximate and optimal digital interarticular channel of atlas for 60 participants. Angles of channels, diameters of inscribed circles, long and short axes of ellipses were measured and recorded, and gender-specific analysis was also performed.Results.The channels provided sufficient space for one or two screws, and the parameters of channels are described. While the channels of females were smaller than that of males, no significant difference of angles between males and females were observed.Conclusion.Our study demonstrates the radiological features of approximate digital interarticular channels, optimal digital interarticular channels of atlas, and provides the reference trajectory of anterior transarticular screws and anterior occiput-to-axis screws. Additionally, we provide a protocol that can help make a pre-operative plan for accurate placement of anterior transarticular screws and anterior occiput-to-axis screws.
Open AccessA novel computed method to reconstruct the bilateral digital interarticular channel of atlas and its use on the anterior upper cervical screw fixation
Purpose.To investigate a novel computed method to reconstruct the bilateral digital interarticular channel of atlas and its potential use on the anterior upper cervical screw fixation.Methods.We have used the reverse engineering software (image-processing software and computer-aided design software) to create the approximate and optimal digital interarticular channel of atlas for 60 participants. Angles of channels, diameters of inscribed circles, long and short axes of ellipses were measured and recorded, and gender-specific analysis was also performed.Results.The channels provided sufficient space for one or two screws, and the parameters of channels are described. While the channels of females were smaller than that of males, no significant difference of angles between males and females were observed.Conclusion.Our study demonstrates the radiological features of approximate digital interarticular channels, optimal digital interarticular channels of atlas, and provides the reference trajectory of anterior transarticular screws and anterior occiput-to-axis screws. Additionally, we provide a protocol that can help make a pre-operative plan for accurate placement of anterior transarticular screws and anterior occiput-to-axis screws.
- Open Access
- 27 April 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (4) , e0124291
The Accuracy of a Method for Printing Three-Dimensional Spinal Models
To study the morphology of the human spine and new spinal fixation methods, scientists require cadaveric specimens, which are dependent on donation. However, in most countries, the number of people willing to donate their body is low. A 3D printed model could be an alternative method for morphology research, but the accuracy of the morphology of a 3D printed model has not been determined. Forty-five computed tomography (CT) scans of cervical, thoracic and lumbar spines were obtained, and 44 parameters of the cervical spine, 120 parameters of the thoracic spine, and 50 parameters of the lumbar spine were measured. The CT scan data in DICOM format were imported into Mimics software v10.01 for 3D reconstruction, and the data were saved in .STL format and imported to Cura software. After a 3D digital model was formed, it was saved in Gcode format and exported to a 3D printer for printing. After the 3D printed models were obtained, the above-referenced parameters were measured again. Paired t-tests were used to determine the significance, set to P0.800. The other ICC values were 0.600; none were <0.600. In this study, we provide a protocol for printing accurate 3D spinal models for surgeons and researchers. The resulting 3D printed model is inexpensive and easily obtained for spinal fixation research.
- 27 April 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (4) , e0124291
Open AccessThe Accuracy of a Method for Printing Three-Dimensional Spinal Models
To study the morphology of the human spine and new spinal fixation methods, scientists require cadaveric specimens, which are dependent on donation. However, in most countries, the number of people willing to donate their body is low. A 3D printed model could be an alternative method for morphology research, but the accuracy of the morphology of a 3D printed model has not been determined. Forty-five computed tomography (CT) scans of cervical, thoracic and lumbar spines were obtained, and 44 parameters of the cervical spine, 120 parameters of the thoracic spine, and 50 parameters of the lumbar spine were measured. The CT scan data in DICOM format were imported into Mimics software v10.01 for 3D reconstruction, and the data were saved in .STL format and imported to Cura software. After a 3D digital model was formed, it was saved in Gcode format and exported to a 3D printer for printing. After the 3D printed models were obtained, the above-referenced parameters were measured again. Paired t-tests were used to determine the significance, set to P0.800. The other ICC values were 0.600; none were <0.600. In this study, we provide a protocol for printing accurate 3D spinal models for surgeons and researchers. The resulting 3D printed model is inexpensive and easily obtained for spinal fixation research.
- Open Access
- 1 December 2014
- Published by Wolters Kluwer Health in Medicine
- Vol. 93 (28) , e242
The Radiological Feature of Anterior Occiput-to-Axis Screw Fixation as it Guides the Screw Trajectory on 3D Printed Models
Anterior occiput-to-axis screw fixation is more suitable than a posterior approach for some patients with a history of posterior surgery. The complex osseous anatomy between the occiput and the axis causes a high risk of injury to neurological and vascular structures, and it is important to have an accurate screw trajectory to guide anterior occiput-to-axis screw fixation. Thirty computed tomography (CT) scans of upper cervical spines were obtained for three-dimensional (3D) reconstruction. Cylinders (1.75 mm radius) were drawn to simulate the trajectory of an anterior occiput-to-axis screw. The imitation screw was adjusted to 4 different angles and measured, as were the values of the maximized anteroposterior width and the left-right width of the occiput (C0) to the C1 and C1 to C2 joints. Then, the 3D models were printed, and an angle guide device was used to introduce the screws into the 3D models referring to the angles calculated from the 3D images. We found the screw angle ranged from α1 (left: 4.99 ± 4.59°; right: 4.28 ± 5.45°) to α2 (left: 20.22 ± 3.61°; right: 19.63 ± 4.94°); on the lateral view, the screw angle ranged from β1 (left: 13.13 ± 4.93°; right: 11.82 ± 5.64°) to β2 (left: 34.86 ± 6.00°; right: 35.01 ± 5.77°). No statistically significant difference was found between the data of the left and right sides. On the 3D printed models, all of the anterior occiput-to-axis screws were successfully introduced, and none of them penetrated outside of the cortex; the mean α4 was 12.00 ± 4.11 (left) and 12.25 ± 4.05 (right), and the mean β4 was 23.44 ± 4.21 (left) and 22.75 ± 4.41 (right). No significant difference was found between α4 and β4 on the 3D printed models and α3 and β3 calculated from the 3D digital images of the left and right sides. Aided with the angle guide device, we could achieve an optimal screw trajectory for anterior occiput-to-axis screw fixation on 3D printed C0 to C2 models.
- 1 December 2014
- Published by Wolters Kluwer Health in Medicine
- Vol. 93 (28) , e242
Open AccessThe Radiological Feature of Anterior Occiput-to-Axis Screw Fixation as it Guides the Screw Trajectory on 3D Printed Models
Anterior occiput-to-axis screw fixation is more suitable than a posterior approach for some patients with a history of posterior surgery. The complex osseous anatomy between the occiput and the axis causes a high risk of injury to neurological and vascular structures, and it is important to have an accurate screw trajectory to guide anterior occiput-to-axis screw fixation. Thirty computed tomography (CT) scans of upper cervical spines were obtained for three-dimensional (3D) reconstruction. Cylinders (1.75 mm radius) were drawn to simulate the trajectory of an anterior occiput-to-axis screw. The imitation screw was adjusted to 4 different angles and measured, as were the values of the maximized anteroposterior width and the left-right width of the occiput (C0) to the C1 and C1 to C2 joints. Then, the 3D models were printed, and an angle guide device was used to introduce the screws into the 3D models referring to the angles calculated from the 3D images. We found the screw angle ranged from α1 (left: 4.99 ± 4.59°; right: 4.28 ± 5.45°) to α2 (left: 20.22 ± 3.61°; right: 19.63 ± 4.94°); on the lateral view, the screw angle ranged from β1 (left: 13.13 ± 4.93°; right: 11.82 ± 5.64°) to β2 (left: 34.86 ± 6.00°; right: 35.01 ± 5.77°). No statistically significant difference was found between the data of the left and right sides. On the 3D printed models, all of the anterior occiput-to-axis screws were successfully introduced, and none of them penetrated outside of the cortex; the mean α4 was 12.00 ± 4.11 (left) and 12.25 ± 4.05 (right), and the mean β4 was 23.44 ± 4.21 (left) and 22.75 ± 4.41 (right). No significant difference was found between α4 and β4 on the 3D printed models and α3 and β3 calculated from the 3D digital images of the left and right sides. Aided with the angle guide device, we could achieve an optimal screw trajectory for anterior occiput-to-axis screw fixation on 3D printed C0 to C2 models.
- 13 November 2014
- Published by Springer Nature in European Spine Journal
- Vol. 24 (4) , 852-858
Percutaneous posterior transdiscal oblique screw fixation with lateral interbody fusion: a radiological and cadaveric study
To design and investigate a novel technique of percutaneous posterior transdiscal oblique screw fixation with lateral interbody fusion. CT scans of 45 patients were collected and imported into Mimics software for three-dimensional (3D) reconstruction. Cylinders were drawn to simulate the trajectory of the oblique screw. Six measurements were obtained for each unit to design a right size cage: a the distance between the intersection of the simulated trajectory of the screw with the inferior border of the upper vertebra and its anteroinferior corner; b the distance between the intersection of the simulated trajectory of the screw with the superior border of the inferior vertebra and its anterosuperior corner; h the height of the intervertebral space; θ the angle between simulated trajectory of screw and the upper endplate of inferior vertebra; uw: the width of the inferior endplate of upper vertebra; iw: the width of upper endplate of inferior vertebra. Three intact adult fresh-frozen cadaveric specimens were obtained, percutaneous posterior transdiscal oblique screw fixation was performed under X-ray apparatus, and interbody cage was implanted by assistance with special self-retaining retractor system and endoscope. According to the results of data measured from 3D images, trapezoid shape interbody cages with suitable size were designed. Percutaneous posterior oblique screw fixation with lateral interbody fusion was performed on three cadaveric specimens successfully. Using specially designed trapezoid shape interbody cages, assisted by intra-operative image intensification and endoscope, it is feasible to perform percutaneous posterior transdiscal oblique screw fixation with lateral interbody fusion technique.
- 13 November 2014
- Published by Springer Nature in European Spine Journal
- Vol. 24 (4) , 852-858
Percutaneous posterior transdiscal oblique screw fixation with lateral interbody fusion: a radiological and cadaveric study
To design and investigate a novel technique of percutaneous posterior transdiscal oblique screw fixation with lateral interbody fusion. CT scans of 45 patients were collected and imported into Mimics software for three-dimensional (3D) reconstruction. Cylinders were drawn to simulate the trajectory of the oblique screw. Six measurements were obtained for each unit to design a right size cage: a the distance between the intersection of the simulated trajectory of the screw with the inferior border of the upper vertebra and its anteroinferior corner; b the distance between the intersection of the simulated trajectory of the screw with the superior border of the inferior vertebra and its anterosuperior corner; h the height of the intervertebral space; θ the angle between simulated trajectory of screw and the upper endplate of inferior vertebra; uw: the width of the inferior endplate of upper vertebra; iw: the width of upper endplate of inferior vertebra. Three intact adult fresh-frozen cadaveric specimens were obtained, percutaneous posterior transdiscal oblique screw fixation was performed under X-ray apparatus, and interbody cage was implanted by assistance with special self-retaining retractor system and endoscope. According to the results of data measured from 3D images, trapezoid shape interbody cages with suitable size were designed. Percutaneous posterior oblique screw fixation with lateral interbody fusion was performed on three cadaveric specimens successfully. Using specially designed trapezoid shape interbody cages, assisted by intra-operative image intensification and endoscope, it is feasible to perform percutaneous posterior transdiscal oblique screw fixation with lateral interbody fusion technique.
- Open Access
- 2 April 2014
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 29 (9) , 2032-2039
The Relationship Between Vitamin A and Risk of Fracture: Meta-Analysis of Prospective Studies
Osteoporotic fracture is a significant cause of morbidity and mortality and is a challenging global health problem. Previous reports of the relation between vitamin A intake or blood retinol and risk of fracture were inconsistent. We searched Medline and Embase to assess the effects of vitamin A (or retinol or beta‐carotene but not vitamin A metabolites) on risk of hip and total fracture. Only prospective studies were included. We pooled data with a random effects meta‐analysis with adjusted relative risk (adj.RR) and 95% confidence interval (CI). We used Q statistic and I2 statistic to assess heterogeneity and Egger's test to assess publication bias. Eight vitamin A (or retinol or beta‐carotene) intake studies (283,930 participants) and four blood retinol level prospective studies (8725 participants) were included. High intake of vitamin A and retinol were shown to increase risk of hip fracture (adj.RR [95% CI] = 1.29 [1.07, 1.57] and 1.40 [1.03, 1.91], respectively), whereas beta‐carotene intake was not found to increase the risk of hip fracture (adj.RR [95% CI] = 0.82 [0.59, 1.14]). Both high or low level of blood retinol was shown to increase the risk of hip fracture (adj.RR [95% CI] = 1.87 [1.31, 2.65] and 1.56 [1.09, 2.22], respectively). The risk of total fracture does not differ significantly by level of vitamin A (or retinol) intake or by blood retinol level. Dose‐response meta‐analysis shows a U‐shaped relationship between serum retinol level and hip fracture risk. Our meta‐analysis suggests that blood retinol level is a double‐edged sword for risk of hip fracture. To avoid the risk of hip fracture caused by too low or too high a level of retinol concentration, we suggest that intake of beta‐carotene (a provitamin A), which should be converted to retinol in blood, may be better than intake of retinol from meat, which is directly absorbed into blood after intake. © 2014 American Society for Bone and Mineral Research.
- 2 April 2014
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 29 (9) , 2032-2039
Open AccessThe Relationship Between Vitamin A and Risk of Fracture: Meta-Analysis of Prospective Studies
Osteoporotic fracture is a significant cause of morbidity and mortality and is a challenging global health problem. Previous reports of the relation between vitamin A intake or blood retinol and risk of fracture were inconsistent. We searched Medline and Embase to assess the effects of vitamin A (or retinol or beta‐carotene but not vitamin A metabolites) on risk of hip and total fracture. Only prospective studies were included. We pooled data with a random effects meta‐analysis with adjusted relative risk (adj.RR) and 95% confidence interval (CI). We used Q statistic and I2 statistic to assess heterogeneity and Egger's test to assess publication bias. Eight vitamin A (or retinol or beta‐carotene) intake studies (283,930 participants) and four blood retinol level prospective studies (8725 participants) were included. High intake of vitamin A and retinol were shown to increase risk of hip fracture (adj.RR [95% CI] = 1.29 [1.07, 1.57] and 1.40 [1.03, 1.91], respectively), whereas beta‐carotene intake was not found to increase the risk of hip fracture (adj.RR [95% CI] = 0.82 [0.59, 1.14]). Both high or low level of blood retinol was shown to increase the risk of hip fracture (adj.RR [95% CI] = 1.87 [1.31, 2.65] and 1.56 [1.09, 2.22], respectively). The risk of total fracture does not differ significantly by level of vitamin A (or retinol) intake or by blood retinol level. Dose‐response meta‐analysis shows a U‐shaped relationship between serum retinol level and hip fracture risk. Our meta‐analysis suggests that blood retinol level is a double‐edged sword for risk of hip fracture. To avoid the risk of hip fracture caused by too low or too high a level of retinol concentration, we suggest that intake of beta‐carotene (a provitamin A), which should be converted to retinol in blood, may be better than intake of retinol from meat, which is directly absorbed into blood after intake. © 2014 American Society for Bone and Mineral Research.
- 1 January 2014
- Published by Elsevier in The Spine Journal
- Vol. 14 (1) , 80-86
The influence of cervical spine position on the three anterior endoscopic approaches to the craniovertebral junction: an imaging study
- 1 January 2014
- Published by Elsevier in The Spine Journal
- Vol. 14 (1) , 80-86
The influence of cervical spine position on the three anterior endoscopic approaches to the craniovertebral junction: an imaging study
- 1 July 2013
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 95-B (7) , 977-982
A radiological and cadaveric study of oblique lumbar interbody fixation in patients with normal spinal anatomy
The purpose of this study was to determine whether it would be feasible to use oblique lumbar interbody fixation for patients with degenerative lumbar disease who required a fusion but did not have a spondylolisthesis. A series of CT digital images from 60 patients with abdominal disease were reconstructed in three dimensions (3D) using Mimics v10.01: a digital cylinder was superimposed on the reconstructed image to simulate the position of an interbody screw. The optimal entry point of the screw and measurements of its trajectory were recorded. Next, 26 cadaveric specimens were subjected to oblique lumbar interbody fixation on the basis of the measurements derived from the imaging studies. These were then compared with measurements derived directly from the cadaveric vertebrae. Our study suggested that it is easy to insert the screws for L1/2, L2/3 and L3/4 fixation: there was no significant difference in measurements between those of the 3-D digital images and the cadaveric specimens. For L4/5 fixation, part of L5 inferior articular process had to be removed to achieve the optimal trajectory of the screw. For L5/S1 fixation, the screw heads were blocked by iliac bone: consequently, the interior oblique angle of the cadaveric specimens was less than that seen in the 3D digital images. We suggest that CT scans should be carried out pre-operatively if this procedure is to be adopted in clinical practice. This will assist in determining the feasibility of the procedure and will provide accurate information to assist introduction of the screws. Cite this article: Bone Joint J 2013;95-B:977–82.
- 1 July 2013
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 95-B (7) , 977-982
A radiological and cadaveric study of oblique lumbar interbody fixation in patients with normal spinal anatomy
The purpose of this study was to determine whether it would be feasible to use oblique lumbar interbody fixation for patients with degenerative lumbar disease who required a fusion but did not have a spondylolisthesis. A series of CT digital images from 60 patients with abdominal disease were reconstructed in three dimensions (3D) using Mimics v10.01: a digital cylinder was superimposed on the reconstructed image to simulate the position of an interbody screw. The optimal entry point of the screw and measurements of its trajectory were recorded. Next, 26 cadaveric specimens were subjected to oblique lumbar interbody fixation on the basis of the measurements derived from the imaging studies. These were then compared with measurements derived directly from the cadaveric vertebrae. Our study suggested that it is easy to insert the screws for L1/2, L2/3 and L3/4 fixation: there was no significant difference in measurements between those of the 3-D digital images and the cadaveric specimens. For L4/5 fixation, part of L5 inferior articular process had to be removed to achieve the optimal trajectory of the screw. For L5/S1 fixation, the screw heads were blocked by iliac bone: consequently, the interior oblique angle of the cadaveric specimens was less than that seen in the 3D digital images. We suggest that CT scans should be carried out pre-operatively if this procedure is to be adopted in clinical practice. This will assist in determining the feasibility of the procedure and will provide accurate information to assist introduction of the screws. Cite this article: Bone Joint J 2013;95-B:977–82.
- Open Access
- 21 May 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (5) , e63995
Fusion versus Nonfusion for Surgically Treated Thoracolumbar Burst Fractures: A Meta-Analysis
Background Posterior pedicle screw fixation has become a popular method for treating thoracolumbar burst fractures. However, it remains unclear whether additional fusion could improve clinical and radiological outcomes. This meta-analysis was performed to evaluate the effectiveness of fusion as a supplement to pedicle screw fixation for thoracolumbar burst fractures. Methodology/Principal Findings MEDLINE, OVID, Springer, and Google Scholar were searched for relevant randomized and quasi-randomized controlled trials that compared the clinical and radiological efficacy of fusion versus nonfusion for thoracolumbar burst fractures managed by posterior pedicle screw fixation. Risk of bias in included studies was assessed using the Cochrane Risk of Bias tool. We generated pooled risk ratios or weighted mean differences across studies. Based on predefined inclusion criteria, 4 eligible trials with a total of 220 patients were included in this meta-analysis. The mean age of the patients was 35.1 years. 96.8% of the fractures were located at T12 to L1 level. Baseline characteristics were similar between the fusion and nonfusion groups. No significant difference was identified between the two groups regarding radiological outcome, functional outcome, neurologic improvement, and implant failure rate. The pooled data showed that the nonfusion group was associated with significantly reduced operative time (p<0.0001) and blood loss (p = 0.0003). Conclusions/Significances The results of this meta-analysis suggested that fusion was not necessary when thoracolumbar burst fracture was treated by posterior pedicle screw fixation. More randomized controlled trials with high quality are still needed in the future.
- 21 May 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (5) , e63995
Open AccessFusion versus Nonfusion for Surgically Treated Thoracolumbar Burst Fractures: A Meta-Analysis
Background Posterior pedicle screw fixation has become a popular method for treating thoracolumbar burst fractures. However, it remains unclear whether additional fusion could improve clinical and radiological outcomes. This meta-analysis was performed to evaluate the effectiveness of fusion as a supplement to pedicle screw fixation for thoracolumbar burst fractures. Methodology/Principal Findings MEDLINE, OVID, Springer, and Google Scholar were searched for relevant randomized and quasi-randomized controlled trials that compared the clinical and radiological efficacy of fusion versus nonfusion for thoracolumbar burst fractures managed by posterior pedicle screw fixation. Risk of bias in included studies was assessed using the Cochrane Risk of Bias tool. We generated pooled risk ratios or weighted mean differences across studies. Based on predefined inclusion criteria, 4 eligible trials with a total of 220 patients were included in this meta-analysis. The mean age of the patients was 35.1 years. 96.8% of the fractures were located at T12 to L1 level. Baseline characteristics were similar between the fusion and nonfusion groups. No significant difference was identified between the two groups regarding radiological outcome, functional outcome, neurologic improvement, and implant failure rate. The pooled data showed that the nonfusion group was associated with significantly reduced operative time (p<0.0001) and blood loss (p = 0.0003). Conclusions/Significances The results of this meta-analysis suggested that fusion was not necessary when thoracolumbar burst fracture was treated by posterior pedicle screw fixation. More randomized controlled trials with high quality are still needed in the future.
- 10 April 2013
- Published by Springer Nature in European Spine Journal
- Vol. 22 (8) , 1741-1749
Minimally invasive versus open transforaminal lumbar interbody fusion: a meta-analysis based on the current evidence
This is a meta-analysis of randomized and non-randomized studies comparing the clinical and radiological efficacy of minimally invasive (MI) and conventional open transforaminal lumbar interbody fusion (open-TLIF) for degenerative lumbar diseases. A literature search of the MEDLINE database identified 11 studies that met our inclusion criteria. A total of 785 patients were examined. Pooled estimates of clinical and radiological outcomes, and corresponding 95 % confidence intervals were calculated. The pooled data revealed that MI-TLIF was associated with less blood loss, shorter hospital stay, and a trend of better functional outcomes when compared with open-TLIF. However, MI-TLIF significantly increased the intraoperative X-ray exposure. Both techniques had similar operative time, complication rate, and re-operation rate. Based on the available evidence, MI-TLIF for degenerative lumbar diseases might lead to better patient-based outcomes. MI-TLIF would be a promising procedure, but extra efforts are needed to reduce its intraoperative radiation exposure. More randomized controlled trials are needed to compare these two surgical options.
- 10 April 2013
- Published by Springer Nature in European Spine Journal
- Vol. 22 (8) , 1741-1749
Minimally invasive versus open transforaminal lumbar interbody fusion: a meta-analysis based on the current evidence
This is a meta-analysis of randomized and non-randomized studies comparing the clinical and radiological efficacy of minimally invasive (MI) and conventional open transforaminal lumbar interbody fusion (open-TLIF) for degenerative lumbar diseases. A literature search of the MEDLINE database identified 11 studies that met our inclusion criteria. A total of 785 patients were examined. Pooled estimates of clinical and radiological outcomes, and corresponding 95 % confidence intervals were calculated. The pooled data revealed that MI-TLIF was associated with less blood loss, shorter hospital stay, and a trend of better functional outcomes when compared with open-TLIF. However, MI-TLIF significantly increased the intraoperative X-ray exposure. Both techniques had similar operative time, complication rate, and re-operation rate. Based on the available evidence, MI-TLIF for degenerative lumbar diseases might lead to better patient-based outcomes. MI-TLIF would be a promising procedure, but extra efforts are needed to reduce its intraoperative radiation exposure. More randomized controlled trials are needed to compare these two surgical options.