Bioinformatic identification of lentivirus transfer plasmid contamination causing false-positive HIV NAT results in a high-throughput molecular screening laboratory
Open Access
- 7 April 2026
- journal article
- Published by American Society for Microbiology in Microbiology Spectrum
- Vol. 14 (4) , e0250025
Abstract
Blood screening programs require ultra-sensitive high-throughput PCRs to ensure the absence of pathogens to keep blood components safe for recipients. We present here details of an investigation wherein samples undergoing screening using a high-throughput multi-pathogen NAT assay began to exhibit an abnormally high HIV false reactivity rate. NHS Blood and Transplant usually sees up to 10 HIV reactive samples per year, but this increased to over 100 in just a few days. Investigations into the cause were imperative to prevent recurrence. Analyzer and reagent issues were ruled out and environmental swabbing revealed extensive contamination of the laboratory, with 356 of 392 swabs testing positive. We demonstrate the methods by which we used amplicon NGS and a custom bioinformatic approach to differentiate between expected amplicons, PCR artifact, and contaminant sequences from extracted false-positive samples. Our investigation was able to trace the source of contamination to an unexpected source, a lentivirus transfer plasmid, containing the long terminal repeat (LTR) region of HIV-1, from a neighboring laboratory. This incident demonstrates the risks of false reactivity from HIV-derived lentiviral vectors, which has also been seen in patients receiving lentiviral vectors as part of gene or CAR T-cell therapies. The nature of the contaminant meant that there was no risk to donors, recipients, or staff. It did, however, demonstrate the critical importance of facility design and operation in plasmid manufacturing sites to prevent the spread of such contaminants and avoid unexpected downstream consequences such as those encountered in the screening laboratory. IMPORTANCE: This paper describes a large-scale contamination incident that occurred at a critically important high-throughput screening laboratory resulting in a significant spike of positives in the HIV screening. We describe the use of NGS and a custom bioinformatics approach that enabled us to identify the unexpected source of the contamination—a lentivirus transfer plasmid, containing the long terminal repeat (LTR) region of HIV-1, being produced in a neighboring laboratory. This incident demonstrates the risks of false reactivity from HIV-derived lentiviral vectors, which has also been seen in patients receiving lentiviral vectors as part of gene or CAR T-cell therapies. The nature of the contaminant meant that there was no risk to donors, recipients, or staff. It did, however, demonstrate the critical importance of facility design and operation in plasmid manufacturing sites to prevent the spread of such contaminants and avoid unexpected downstream consequences such as those encountered in the screening laboratory.Keywords
Funding Information
- National Institute for Health and Care Research (NIHR203338)
- National Health and Medical Research Council (GNT2025445)
This publication has 15 references indexed in Scilit:
- Castanet: a pipeline for rapid analysis of targeted multi-pathogen genomic dataBioinformatics, 2024
- Carryover Contamination-Controlled Amplicon Sequencing Workflow for Accurate Qualitative and Quantitative Detection of Pathogens: a Case Study on SARS-CoV-2Microbiology Spectrum, 2023
- A decontamination strategy for resolving SARS-CoV-2 amplicon contamination in a next-generation sequencing laboratoryArchives of Virology, 2022
- False-Positive Human Immunodeficiency Virus Test Results in Patients Receiving Lentivirus-Based Chimeric Antigen Receptor T-Cell Therapy: Case Report, Review of the Literature, and Proposed RecommendationsThe Journal of Infectious Diseases, 2021
- Next generation sequencing reveals limitation of qPCR methods in quantifying emerging antibiotic resistance genes (ARGs) in the environmentApplied Microbiology and Biotechnology, 2021
- False-Positive Results for Human Immunodeficiency Virus Type 1 Nucleic Acid Amplification Testing in Chimeric Antigen Receptor T Cell TherapyJournal of Clinical Microbiology, 2019
- Efficient Architecture-Aware Acceleration of BWA-MEM for Multicore Systems2019
- History and Future of Nucleic Acid Amplification Technology Blood Donor TestingTransfusion Medicine and Hemotherapy, 2019
- Trimmomatic: a flexible trimmer for Illumina sequence dataBioinformatics, 2014
- Isolation of a T-Lymphotropic Retrovirus from a Patient at Risk for Acquired Immune Deficiency Syndrome (AIDS)Science, 1983